journal article·2015-12

Effect of inflammatory conditions and H2O2 on bare and coated Ti–6Al–4V surfaces: Corrosion behavior, metal ion release and Ca-P formation under long-term immersion in DMEM

Sarah Höhn, Sannakaisa Virtanen

Publisher page

Abstract

Abstract The surface oxide film and calcium-phosphate (Ca-P) formation on Ti–6Al–4V during long-term immersion in biological environments play a decisive role for the biocompatibility of the implant. Hence, the aim of the study was to evaluate the corrosion resistance, metal ion release and Ca-P formation in DMEM under physiological conditions at pH values of 7.4 and in comparison under simulated inflammatory conditions with pH 5 and in presence of H 2 O 2 . Furthermore, the influence of the immersion conditions was investigated on different surface treatments: on bare Ti–6Al–4V, after anodization, and for TiO 2 nanoparticle (NP) and hydroxyapatite (HA)-incorporated TiO 2 -NP coatings. In the absence of H 2 O 2 , the impedance response indicated a stable thin oxide film and Ca-P formation after 28 days or 56 days depending on the coating, while under inflammatory conditions the Ca-P formation on the surface is time-delayed and dissolution of the anodized oxide layer as well as selective etching of the β-phase and phase boundaries in case of the bare alloy occur. Electrochemical impedance spectroscopy (EIS), however, indicates a good general corrosion behavior in all cases. The quantities of Ti, Al and V released from the bare and coated Ti–6Al–4V alloy markedly increased with decreasing pH (pH ≤ 5). Although the rapid increase of metal release was observed for all samples at pH 5, the quantities were significantly higher for the bare and anodized alloy than after coating with TiO 2 -NP or HA.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (33)

Show source-provided references
1. Wintermantel · 2009
2. Ti based biomaterials, the ultimate choice for orthopaedic implants – a review10.1016/j.pmatsci.2008.06.004 ↗
3. Surface modification of titanium, titanium alloys, and related materials for biomedical applications10.1016/j.mser.2004.11.001 ↗
4. Zardiackas · 2006
5. Brunette · 2001
6. Apatite-forming ability of titanium in terms of pH of the exposed solution10.1098/rsif.2012.0107 ↗
7. Biomedical applications of titanium and its alloys
8. In vivo metallic biomaterials and surface modification10.1016/S0921-5093(99)00101-X ↗
9. Toxic and essential metal interactions10.1146/annurev.nutr.17.1.37 ↗
10. Aluminum effects on blood chemistry and long bone development in the chick embryo10.1007/s002040050111 ↗
11. Nordberg · 2014
12. Effect of hydrogen peroxide on titanium surfaces: in situ imaging and step-polarization impedance spectroscopy of commercially pure titanium and titanium, 6-aluminum 4-vanadium10.1002/jbm.a.10116 ↗
13. Titanium-hydrogen peroxide interaction: model studies of the influence of the inflammatory response on titanium implants10.1016/0142-9612(89)90019-7 ↗
14. Variation of oxide films on titanium induced by osteoblast-like cell culture and the influence of an H2O2 pretreatment10.1002/(SICI)1097-4636(199805)40:2<244::AID-JBM9>3.0.CO;2-L ↗
15. Warmuth · 2005
16. An in-vitro study of H2O2-treated titanium surfaces in contact with blood plasma and a simulated body fluid10.1016/0267-6605(93)90065-F ↗
17. Corrosion behaviour of titanium in biofluids containing H2O2 studied by electrochemical impedance spectroscopy10.1016/S0010-938X(00)00107-4 ↗
18. Dissemond · 2006 · vol. 1 · 15
19. Biocorrosion of TiO2 nanoparticle coating of Ti–6Al–4V in DMEM under specific in vitro conditions10.1016/j.apsusc.2014.12.114 ↗
20. Hartree-Slater subshell photoionization cross-sections at 1254 and 1487eV10.1016/0368-2048(76)80015-1 ↗
21. Relative intensities in photoelectron spectroscopy of atoms and molecules10.1016/0368-2048(76)80025-4 ↗
22. Oriented growth of phosphates on polycrystalline titanium in a process mimicking biomineralization10.1016/S0022-0248(99)00315-2 ↗
23. Titanium gel made from metallic titanium and hydrogen peroxide10.1016/0021-9797(89)90117-3 ↗
24. Surface modification of Ti–6Al–4V alloy for biomineralization and specific biological response: Part I. Inorganic modification10.1007/s10856-011-4246-2 ↗
25. Properties of passive film formed on CP titanium, Ti–6Al–4V and Ti–13.4Al–29Nb alloys in simulated human body conditions10.1016/j.intermet.2004.10.001 ↗
26. Influence of CO2 exposure on pH value, electrochemical properties, and the formation of calcium-phosphate on Ti–6Al–4V under adjusted in vitro conditions in DMEM10.1016/j.susc.2015.02.007 ↗
27. Corrosion behaviour of Ti–6Al–7Nb and Ti–6Al–4V ELI alloys in the simulated body fluid solution by electrochemical impedance spectroscopy10.1016/j.electacta.2006.06.018 ↗
28. Corrosion characterization of titanium alloys by electrochemical techniques10.1016/j.electacta.2005.02.121 ↗
29. Electrochemical impedance spectroscopic characterization of titanium during alkali treatment and apatite growth in simulated body fluid10.1016/j.electacta.2007.06.040 ↗
30. Electrochemical studies on the stability and corrosion resistance of titanium-based implant materials10.1016/S0142-9612(00)00309-4 ↗
31. Study of the corrosion behavior of titanium and some of its alloys for biomedical and dental implant applications10.1016/S0022-0728(99)00260-0 ↗
32. Passive film on orthopaedic TiAlV alloy formed in physiological solution investigated by X-ray photoelectron spectroscopy10.1016/S0142-9612(00)00145-9 ↗
33. Browne · Effect of mechanical surface pretreatment on metal ion release · 2000 · 21 · 385