journal article·2018-09Open access

Synthesis of biofunctional coating for a TiZr alloy: Surface, electrochemical, and biological characterizations

Jairo M. Cordeiro, Heloisa N. Pantaroto, Emanuella M. Paschoaleto, Elidiane C. Rangel, Nilson C. da Cruz, Cortino Sukotjo, Valentim A.R. Barão

Abstract

Abstract This study formed a biofunctional coating for a Ti15Zr alloy to improve the surface characteristics, the electrochemical behavior, and the biological properties of this implant material. Ti15Zr discs (15 mm in diameter × 1 mm thickness) were obtained in three versions: machined, SLA®-treated (control groups), and modified by plasma electrolytic oxidation (PEO) (experimental group). Surface features such as topography, composition, surface roughness, surface free energy, and hardness were assessed. Electrochemical tests were conducted with body fluid solution (pH 7.4). The albumin protein adsorption was measured by the bicinchoninic acid method, and the adhesion of Streptococcus sanguinis was determined. The surface treatments modified the material’s topography. SLA promoted surface roughness higher than that of the other groups, whereas PEO surfaces presented the highest values of hardness and surface free energy. PEO increased the polarization resistance and the corrosion potential, and decreased capacitance and corrosion current density values. In addition, plasma treatment improved the albumin adsorption without being favorable to biofilm adhesion. PEO appears to be the most promising alternative for Ti15Zr alloys, since it improved surface characteristics and electrochemical behavior, as well as enhancing the adsorption of albumin on the material surface with fewer tendencies to bacterial adhesion.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (52)

Show source-provided references
1. Clinical evidence on titanium–zirconium dental implants: a systematic review and meta-analysis10.1016/j.ijom.2016.01.004 ↗
2. Survival rate of titanium-zirconium narrow diameter dental implants versus commercially pure titanium narrow diameter dental implants: a systematic review10.1111/cid.12527 ↗
3. Can degradation products released from dental implants affect peri-implant tissues?10.1111/jre.12479 ↗
4. Human macrophage response to UHMWPE, TiAlV, CoCr, and alumina particles: Analysis of multiple cytokines using protein arrays10.1002/jbm.a.31467 ↗
5. Influence of the carbon content on the corrosion and tribocorrosion performance of Ti-DLC coatings for biomedical alloys10.1016/j.triboint.2015.03.007 ↗
6. Electrochemical & osteoblast adhesion study of engineered TiO2 nanotubular surfaces on titanium alloys10.1016/j.msec.2015.07.024 ↗
7. Is there scientific evidence favoring the substitution of commercially pure titanium with titanium alloys for the manufacture of dental implants?10.1016/j.msec.2016.10.025 ↗
8. Improved osseointegration of long-term stored SLA implant by hydrothermal sterilization10.1016/j.jmbbm.2015.08.038 ↗
9. Clinical field trial examining an implant with a sand-blasted, acid-etched surface10.1902/jop.2007.060294 ↗
10. Bioactive coatings on Ti6Al4V alloy formed by plasma electrolytic oxidation10.1016/j.surfcoat.2015.07.053 ↗
11. Surface characterization and corrosion behavior of calcium phosphate-base composite layer on titanium and its alloys via plasma electrolytic oxidation: a review paper10.1016/j.msec.2015.07.058 ↗
12. Electrochemical behavior of bioactive coatings on cp-Ti surface for dental application10.1016/j.corsci.2015.07.019 ↗
13. The in vitro and in vivo performance of a strontium-containing coating on the low-modulus Ti35Nb2Ta3Zr alloy formed by micro-arc oxidation10.1007/s10856-015-5533-0 ↗
14. Three-species biofilm model onto plasma-treated titanium implant surface10.1016/j.colsurfb.2017.01.035 ↗
15. Antifouling properties of micro arc oxidation coatings containing Cu2O/ZnO nanoparticles on Ti6Al4V10.1016/j.ijrmhm.2015.10.003 ↗
16. Bioactivity of coatings formed on Ti–13Nb–13Zr alloy using plasma electrolytic oxidation10.1016/j.msec.2014.12.073 ↗
17. Production of a biofunctional titanium surface using plasma electrolytic oxidation and glow-discharge plasma for biomedical applications10.1116/1.4944061 ↗
18. Metal release from ceramic coatings for dental implants10.1016/j.dental.2013.12.011 ↗
19. In vitro corrosion performance of PEO coated Ti and Ti6Al4V used for dental and orthopaedic implants10.1016/j.surfcoat.2016.08.018 ↗
20. Characterization and colorization of microarc-oxidized layers of binary titanium alloys10.1016/j.jallcom.2017.10.181 ↗
21. Electrochemical modification of Ti–13Nb–13Zr alloy surface in phosphate based solutions10.1016/j.surfcoat.2016.02.025 ↗
22. Development of binary and ternary titanium alloys for dental implants10.1016/j.dental.2017.07.013 ↗
23. Effects of dextrose and lipopolysaccharide on the corrosion behavior of a Ti-6Al-4V alloy with a smooth surface or treated with double-acid-etching10.1371/journal.pone.0093377 ↗
24. The role of nicotine, cotinine and caffeine on the electrochemical behavior and bacterial colonization to cp-Ti10.1016/j.msec.2015.06.026 ↗
25. Preparation of SBF with different HCO-3 content and its influence on the composition of biomimetic apatites10.1016/j.actbio.2005.11.001 ↗
26. The effect of Streptococcus mutans and Candida glabrata on Candida albicans biofilms formed on different surfaces10.1016/j.archoralbio.2008.02.015 ↗
27. Characterization and formation of hydroxyapatite on Ti6Al4V coated by plasma electrolytic oxidation10.1016/j.jallcom.2012.11.024 ↗
28. Effects of electrolytic concentration on properties of micro-arc film on Ti6Al4V alloy
29. Structure, corrosion resistance and in vitro bioactivity of Ca and P containing TiO2 coating fabricated on NiTi alloy by plasma electrolytic oxidation10.1016/j.apsusc.2015.08.228 ↗
30. Toward optimizing dental implant performance: Surface characterization of Ti and TiZr implant materials10.1016/j.dental.2016.10.001 ↗
31. Torre, microstructure and mechanical properties of Ti–15Zr alloy used as dental implant material10.1016/j.jmbbm.2016.05.008 ↗
32. The removal torque of titanium screw inserted in rabbit tibia treated by dual acid etching10.1016/S0142-9612(03)00218-7 ↗
33. Relationship between surface properties (roughness, wettability and morphology) of titanium and dental implant removal torque10.1016/j.jmbbm.2007.12.002 ↗
34. Effect of roughness, wettability and morphology of engineered titanium surfaces on osteoblast-like cell adhesion10.1016/j.colsurfa.2009.12.017 ↗
35. Nano modified SLA process for titanium implants10.1016/j.matlet.2016.08.079 ↗
36. Roughness induced dynamic changes of wettability of acid etched titanium implant modifications10.1016/j.biomaterials.2003.08.015 ↗
37. Formation and properties of bioactive barium titanate coatings produced by plasma electrolytic oxidation
38. Study of the interaction of inorganic and organic compounds of cell culture medium with a Ti surface10.1016/j.actbio.2009.06.019 ↗
39. Albumin loaded PEO coatings on Ti — potential as drug eluting systems10.1016/j.surfcoat.2015.10.045 ↗
40. A review of improved fixation methods for dental implants. Part I: surface optimization for rapid osseointegration10.1016/j.jpor.2014.11.007 ↗
41. Biofunctionalization of Ti–13Nb–13Zr alloy surface by plasma electrolytic oxidation. Part I10.1016/j.surfcoat.2015.06.035 ↗
42. Morphology and antimicrobial properties of hydroxyapatite–titanium oxide layers on the surface of Ti–6Al–4V alloy10.1016/j.surfcoat.2015.11.050 ↗
43. Crystalline anatase-rich titanium can reduce adherence of oral streptococci10.1080/08927014.2014.922962 ↗
44. Bacterial adhesion on amorphous and crystalline metal oxide coatings10.1016/j.msec.2015.07.031 ↗
45. Bacterial colonization of the internal part of two-stage implants. An in vivo study10.1034/j.1600-0501.1993.040307.x ↗
46. Effect of material characteristics and/or surface topography on biofilm development10.1111/j.1600-0501.2006.01353.x ↗
47. Influence of topography and hydrophilicity on initial oral biofilm formation on microstructured titanium surfaces in vitro10.1111/j.1600-0501.2011.02184.x ↗
48. Physico-chemistry of initial microbial adhesive interactions – its mechanisms and methods for study10.1111/j.1574-6976.1999.tb00396.x ↗
49. Adhesion of streptococcus thermophilus to stainless steel with different surface topography and roughness10.1080/08927019709378331 ↗
50. A pilot study to evaluate the success and survival rate of titanium-zirconium implants in partially edentulous patients: results after 24 months of follow-up10.1111/j.1600-0501.2011.02231.x ↗
51. Biomimetic apatite formation on chemically treated titanium10.1016/j.biomaterials.2003.08.009 ↗
52. Corrosion resistance of a self-healing micro-arc oxidation/polymethyltrimethoxysilane composite coating on magnesium alloy AZ3110.1016/j.corsci.2017.01.025 ↗