journal article·2014-04

Enhanced corrosion resistance and hemocompatibility of biomedical NiTi alloy by atmospheric-pressure plasma polymerized fluorine-rich coating

Penghui Li, Limin Li, Wenhao Wang, Weihong Jin, Xiangmei Liu, Kelvin W.K. Yeung, Paul K. Chu

Publisher page

Abstract

Abstract To improve the corrosion resistance and hemocompatibility of biomedical NiTi alloy, hydrophobic polymer coatings are deposited by plasma polymerization in the presence of a fluorine-containing precursor using an atmospheric-pressure plasma jet. This process takes place at a low temperature in air and can be used to deposit fluoropolymer films using organic compounds that cannot be achieved by conventional polymerization techniques. The composition and chemical states of the polymer coatings are characterized by fourier transform infrared spectroscopy (FTIR) and X-ray photoelectron spectroscopy (XPS). The corrosion behavior of the coated and bare NiTi samples is assessed and compared by polarization tests and electrochemical impedance spectroscopy (EIS) in physiological solutions including simulated body fluids (SBF) and Dulbecco's Modified Eagle's medium (DMEM). The corrosion resistance of the coated NiTi alloy is evidently improved. Protein adsorption and platelet adhesion tests reveal that the adsorption ratio of albumin to fibrinogen is increased and the number of adherent platelets on the coating is greatly reduced. The plasma polymerized coating renders NiTi better in vitro hemocompatibility and is promising as a protective and hemocompatible coating on cardiovascular implants.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Metal and Thin Film Mechanics · Bone Tissue Engineering Materials · Diamond and Carbon-based Materials Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (39)

Show source-provided references
1. Transluminally placed coilspring endarterial tubegrafts: long-term patency in canine popliteal artery10.1097/00004424-196909000-00008 ↗
2. New frontiers in cardiology: drug-eluting stents: part I10.1161/01.CIR.0000069330.41022.90 ↗
3. Characterization of surface-modified nickel titanium alloys10.1016/S0921-5093(02)00818-3 ↗
4. Surface, corrosion and biocompatibility aspects of nitinol as an implant material
5. Interactions between whole blood and hydrophilic or hydrophobic glass surfaces: kinetics of cell adhesion10.1016/S0927-7765(99)00049-1 ↗
6. Fluorinated surface-modifying macromolecules: modulating adhesive protein and platelet interactions on a polyether-urethane10.1002/jbm.10033 ↗
7. Hydrophobicity and non-thrombogenicity of nanoscale dual rough surface coated with fluorine-incorporated diamond-like carbon films: bio mimetic surface for blood-contacting medical devices10.1016/j.diamond.2013.06.001 ↗
8. Effects of a tetrafluoroethylene glow discharge on patency of small diameter dacron vascular grafts
9. Surface chemical composition and fibrinogen adsorption-retention of fluoropolymer films deposited from an RF glow discharge10.1007/BF02532828 ↗
10. Expanded polytetrafluoroethylene arterial prostheses in humans: chemical analysis of 79 explanted specimens10.1016/0142-9612(93)90068-D ↗
11. Fluoropassivation and gelatin sealing of polyester arterial prostheses to skip preclotting and constrain the chronic inflammatory response10.1002/jbm.b.31609 ↗
12. Fluorinated diamond-like carbon as antithrombogenic coating for blood-contacting devices10.1002/jbm.a.30512 ↗
13. Super-hydrophobic surfaces produced by plasma fluorination of polybutadiene films10.1021/la020427e ↗
14. Wetting and superhydrophobic properties of PECVD grown hydrocarbon and fluorinated-hydrocarbon coatings10.1016/j.apsusc.2009.12.049 ↗
15. Fabrication and characterization of fluorine-containing films using plasma polymerization of octafuorotoluene10.1016/S0254-0584(99)00121-2 ↗
16. Preparation of lotus-like superhydrophobic fluoropolymer films10.1016/j.apsusc.2010.01.059 ↗
17. Preparation and characterization of a novel fluorinated acrylate resin10.1016/j.jfluchem.2010.03.009 ↗
18. Rapid deposition of transparent super-hydrophobic layers on various surfaces using microwave plasma10.1021/am201181r ↗
19. How useful is SBF in predicting in vivo bone bioactivity10.1016/j.biomaterials.2006.01.017 ↗
20. Estimation of the surface free energy of polymers10.1002/app.1969.070130815 ↗
21. Evaluation of surface energy of solid polymers using different models10.1002/(SICI)1097-4628(20000620)76:12<1831::AID-APP14>3.0.CO;2-Q ↗
22. Hemocompatibility of surface-modified, silicon-incorporated, diamond-like carbon films10.1016/j.actbio.2008.07.031 ↗
23. Fabrication of cell outer membrane mimetic polymer brush on polysulfone surface via RAFT technique10.1016/j.apsusc.2012.06.017 ↗
24. Atmospheric pressure plasma deposition of structurally well-defined polyacrylic acid films10.1021/cm020289e ↗
25. Magnetite-loaded fluorine-containing polymeric micelles for magnetic resonance imaging and drug delivery10.1016/j.biomaterials.2011.12.042 ↗
26. Synthesis and properties novel polyurethane-hexafluorobutyl methacrylate copolymers
27. Atmospheric pressure plasma enhanced chemical vapor deposition of hydrophobic coatings using fluorine-based liquid precursors10.1016/j.surfcoat.2013.03.028 ↗
28. Plasma synthesis of hydrocarbon/fluorocarbon thin films with compositional gradients10.1002/ppap.201300024 ↗
29. Preparation of hydrophobic diamond like carbon films by plasma source ion implantation10.1016/S0168-583X(98)00745-9 ↗
30. Corrosion resistance of aged die cast magnesium alloy AZ91D10.1016/j.msea.2003.08.060 ↗
31. Influence of aggressive ions on the degradation behavior of biomedical magnesium alloy in physiological environment10.1016/j.actbio.2008.05.014 ↗
32. Degradation susceptibility of surgical magnesium alloy in artificial biological fluid containing albumin10.1557/jmr.2007.0241 ↗
33. Mechanical and corrosion study of diamond-like carbon coating on NiTi alloys10.1016/j.surfcoat.2006.07.225 ↗
34. Andrade · 1985 · 105
35. Changes in adsorbed fibrinogen and albumin interactions with polymers indicated by decreases in detergent elutability10.1016/0021-9797(86)90040-8 ↗
36. The effects of temperature and buffer on fibrinogen adsorption from blood plasma to glass10.1080/09205063.1991.9756662 ↗
37. Hemocompatibility of titanium nitride10.1177/039139889201501009 ↗
38. Hemocompatibility of diamond-like carbon coating
39. Blood compatibility of La2O3 doped diamond-like carbon films10.1016/j.diamond.2008.04.011 ↗