journal article·2018-01

Promising Ta-Ti-Zr-Si metallic glass coating without cytotoxic elements for bio-implant applications

J.J. Lai, Y.S. Lin, C.H. Chang, T.Y. Wei, J.C. Huang, Z.X. Liao, C.H. Lin, C.H. Chen

Publisher page

Abstract

Abstract Tantalum (Ta) is considered as one of the most promising metal due to its high corrosion resistance, excellent biocompatibility and cell adhesion/in-growth capabilities. Although there are some researches exploring the biomedical aspects of Ta and Ta based alloys, systematic characterizations of newly developed Ta-based metallic glasses in bio-implant applications is still lacking. This study employs sputtering approach to produced thin-film Ti-based metallic glasses due to the high melting temperature of Ta (3020 °C). Two fully amorphous Ta-based metallic glasses composed of Ta 57 Ti 17 Zr 15 Si 11 and Ta 75 Ti 10 Zr 8 Si 7 are produced and experimentally characterized in terms of their mechanical properties, bio-corrosion properties, surface hydrophilic characteristics, and in-vitro cell viability and cells attachment tests. Compare to conventional pure Ti and Ta metals, the developed Ta-based metallic glasses exhibit higher hardness and lower modulus which are better match to the mechanical properties of bone. MTS assay results show that Ta-based metallic glasses show comparable cell viability and cell attachment rate compared to that of pure Ti and Ta surface in a 72 h in-vitro test.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Metallic Glasses and Amorphous Alloys · Bone Tissue Engineering Materials · Magnesium Alloys: Properties and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (50)

Show source-provided references
1. On the mechanisms of biocompatibility
2. Mediating bone regeneration by means of drug eluting implants: From passive to smart strategies
3. Laser surface textured titanium alloy (Ti–6Al–4 V) –Part II –Studies on bio-compatibility
4. Biphasic silica/apatite co-mineralized collagen scaffolds stimulate osteogenesis and inhibit RANKL-mediated osteoclastogenesis
5. The effects on bone cell of metal ions released from orthopaedic implant. A review
6. Improved adaptability of polyaryl-ether-ether-ketone with texture pattern and graphite-like carbon film for bio-tribological applications
7. Surface characteristics of TiN/ZrN coated nanotubular structure on the Ti–35Ta–xHf alloy for bio-implant applications
8. Biocompatibility and osteogenesis of refractory metal implants titanium, hafnium, niobium, tantalum and rhenium
9. Morphology proliferation, and osteogenic differentiation of mesenchymal stem cells cultured on titanium, tantalum, and chromium surfaces
10. The proliferation and phenotypic expression of human osteoblasts on tantalum metal
11. Mechanism of bonelike apatite formation on bioactive tantalum metal in a simulated body fluid
12. Experimental and clinical performance of porous tantalum in orthopedic surgery
13. Porous tantalum in hip and knee reconstructive surgery
14. Tantalum-based multilayer coating on cobalt alloys in total hip and knee replacement
15. Biofunctionalization strategies on tantalum-based materials for ossesointergrative applications
16. Enhanced osteointegration on tantalum-implanted polyetheretherketone surface with bone-like elastic modulus
17. A. Ito, Enhanced immobilization of acidic protein in the apatite layer via electrostatic interactions in a supersaturated calcium phosphate solution
18. Tantalum as a buffer layer in diamond-like carbon coated artificial hip joints
19. In vitro biocompatibility response of Ti-Zr-Si thin film metallic glasses
20. Improvement of bio-corrosion resistance for Ti42Zr40Si15Ta3 metallic glasses in simulated body fluid by annealing within supercooled liquid region
21. Effect of Cu content on electrochemical response in Ti-based metallic glasses under simulated body fluid
22. On the surface characteristics of a Zr-based bulk metallic glass processed by microelectrical discharge machining
23. The corrosion behavior of in-situ Zr-based metallic glass matrix composites in different corrosive media
24. In vitro cytotoxicity evaluation of element ions released from different prosthodontic materials
25. Rapid screening of potential metallic glasses for biomedical applications
26. Designing biocompatible Ti-based metallic glasses for implant applications
27. The effect of the addition of Ta on the structure crystallization and mechanical properties of Zr-Cu-Ni-Al-Ta bulk metallic glasses
28. Mechanical properties of ZrCuTi thin metallic glass with high content of immiscible tantalum
29. Tantalum based bulk metallic glasses
30. Characterization of mechanical properties and adhesion of Ta-Zr-Cu-Al-Ag thin film metallic glasses
31. Green tea catechin enhances osteogenesis in a bone marrow mesenchymal stem cell line
32. Enhancement of hondrogenesis of human adipose derived stem cells in a hyaluronan-enriched microenvironment
33. Simulated body fluid electrochemical response of Zr-based metallic glasses with different degrees of crystallization
34. Surface hydration: principle and applications toward low-fouling/nonfouling biomaterials
35. Salt effects on the hydration behavior of zwitterionic poly(sulfobetaine methacrylate) aqueous solutions
36. Preparation and apatite layer formation of plasma electrolytic oxidation film on titanium for biomedical application
37. Cathodic alkaline treatment of zirconium to give the ability to form calcium phosphate
38. The influence of pulse plating parameters on the hardness and wear resistance of nickel–alumina composite coatings
39. Influence of hardness on the wear resistance of 17-4 pH stainless steel evaluated by the pin-on-disc testing
40. Electrochemical and biocompatibility response of newly developed TiZr-based metallic glasses
41. Electrochemical impedance spectroscopy characterization of passive film formed on implant Ti-6A- 7Nb alloy in Hank’s solution
42. Corrosion characterization of titanium alloys by electrochemical techniques
43. Microstructures mechanical behavior, cellular response, and hemocompatibility of bulk ultrafine-grained pure tantalum
44. Microstructure mechanical properties, bio-corrosion properties and 2 cytotoxicity of as-extruded Mg-Sr alloys
45. The molecular mechanism of mediation of adsorbed serum proteins to endothelial cells adhesion and growth on biomaterials
46. Influence of surface wettability on competitive protein adsorption and initial attachment of osteoblasts
47. Hydroxyapatite with high carbonate substitutions promotes osteoclast resorption through osteocyte-like cells
48. Adhesion behaviors of human bone marrow stromal cells on different wetatable polymer surface
49. Surface properties and cell response of low metal ion release Ti-6Al-7Nb alloy after multi-step chemical and thermal treatments
50. Modified PMMA cements for a hydrolysis resistant metal–polymer interface in orthopaedic applications