Evaluation of in vitro biocompatibility of open cell iron structures with PEG coating
Source abstract
Abstract
Abstract Biodegradable materials have attracted a great attention in material engineering and medical community in the last decade. In certain cases, degradable implants may overcome the disadvantages of permanent devices. Any biodegradable material for medical use should support the healing process of a diseased tissue or organ and after that degrade slowly in the human body. In orthopaedic applications, biodegradable implants should allow a gradual load transfer to the healing bone as the materials degrade. Iron and iron based alloys have been identified as appropriate materials for the temporary replacement of bones, since they combine high strength at medium corrosion rates. The main goal of this work is evaluation of the in vitro biocompatibility of open cell iron foams with polyethylene glycol (PEG) coating layer for bone repair applications. Based on results of in vitro cytotoxicity studies it was found that the coating of sintered cellular iron samples with PEG layer led to a desired improvement of biocompatibility.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (13)
Show source-provided references
1. Engineering biocompatible implant surfaces. Part I: materials and surfaces10.1016/j.pmatsci.2012.09.001 ↗
2. Fundamentals of medical implant materials
3. Assessing the biocompatibility of degradable metallic materials: state-of-the-art and focus on the potential of genetic regulation10.1016/j.actbio.2010.02.027 ↗
4. Magnesium, iron and zinc alloys, the trifecta of bioresorbable orthopaedic and vascular implantation - a review
5. Progress of biodegradable metals, review10.1016/j.pnsc.2014.08.014 ↗
6. Controlling the degradation kinetics of porous iron by poly (lactic-co-glycolic acid) infiltration for use as temporary medical implants10.1038/srep11194 ↗
7. Effects of alloying elements (Mn Co, Al, W, Sn, B, C and S) on biodegradability and in vitro biocompatibility of pure iron10.1016/j.actbio.2010.11.001 ↗
8. Biocompatibility of pure iron: In vitro assessment of degradation kinetics and cytotoxicity on endothelial cells10.1016/j.msec.2008.12.019 ↗
9. In-vitro cytotoxicity and in-vivo tissue response study of foreign bodies iron based materials
10. Microstructure, cytotoxicity and corrosion of powder-metallurgical iron alloys for biodegradable bone replacement materials10.1016/j.mseb.2011.04.017 ↗
11. Porous biodegradable metals for hard tissue scaffolds: a review
12. Iron–manganese: new class of metallic degradable biomaterials prepared by powder metallurgy10.1179/174329008X284868 ↗
13. An in vitro corrosion study of open cell iron structures with PEG coating for bone replacement applications10.3390/met8070499 ↗