Electrochemical behaviour of ZrTi alloys in artificial physiological solution simulating in vitro inflammatory conditions
Source abstract
Abstract
ZrTi alloys in artificial physiological solution simulating in vitro inflammatory conditions were investigated for biomedical application. Effect of surface treatment on the corrosion resistance of Zr5Ti, Zr25Ti, and Zr45Ti in acidified Ringer’s solution (pH = 3) at 25 ºC was evaluated using electrochemical impedance spectroscopy, potentiodynamic polarization curves, and scanning electrochemical microscopy. Thermal oxidation in air at 500 ºC produces materials with high in vitro corrosion resistance to acidic environments. Higher impedance values related to passivity were observed for oxidized ZrTi alloys compared to as-cast materials. SECM reveals thermal oxidation produced more compact and electrically insulating oxide films
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Hydrogen embrittlement and corrosion behaviors in metals · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (35)
Show source-provided references
1. Biological surface science10.1016/S0039-6028(01)01809-X ↗
2. Magnesium and its alloys as orthopedic biomaterials: a review10.1016/j.biomaterials.2005.10.003 ↗
3. Ti based biomaterials, the ultimate choice for orthopaedic implants—a review10.1016/j.pmatsci.2008.06.004 ↗
4. Surface engineering for bone implants: a trend from passive to active surfaces10.3390/coatings2030095 ↗
5. Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement10.2106/00004623-200004000-00002 ↗
6. Extensive metallosis and necrosis in failed prostheses with cemented titanium-alloy stems and ceramic heads10.1302/0301-620X.82B3.0820352 ↗
7. Effects of soluble metals on human peri-implant cells10.1002/jbm.a.30345 ↗
8. Characterization of 17-4 PH stainless steel foam for biomedical applications in simulated body fluid and artificial saliva environments10.1016/j.msec.2012.12.004 ↗
9. Origins of pitting corrosion10.1179/147842204225016859 ↗
10. Observations of localised instability of passive titanium in chloride solution10.1016/0013-4686(95)00126-Y ↗
11. A preliminary investigation into the microscopic depassivation of passive titanium implant materials in vitro10.1007/BF00154545 ↗
12. The effect of temperature on the nucleation of corrosion pits on titanium in Ringer's physiological solution10.1016/j.biomaterials.2004.02.023 ↗
13. Influence of microstructure and alloying elements on corrosion behaviour of Ti–13Nb–13Zr alloy10.1016/S0010-938X(03)00186-0 ↗
14. Electrochemical characterization of AISI 316L stainless steel in contact with simulated body fluid under infection conditions10.1007/s10856-007-3138-y ↗
15. Solar · 1979 · 259
16. The effects of pH on the repassivation of 304L stainless steel10.1016/0010-938X(83)90049-5 ↗
17. Effect of pH on corrosion behavior of CuCrZr in solution without and with NaCl10.1016/j.jnucmat.2009.08.006 ↗
18. Comparison of metal release from various metallic biomaterials in vitro10.1016/j.biomaterials.2004.02.005 ↗
19. Structural characterization and electrochemical behaviour of laser-sinterized porous Ti–10Mo alloy10.1016/j.corsci.2012.10.036 ↗
20. 1987 · vol. 13 · 725
21. Kovacs · 1996 · 163
22. Enhanced corrosion resistance of Zr coating on biomedical TiNi alloy prepared by plasma immersion ion implantation and deposition10.1016/j.apsusc.2008.06.116 ↗
23. Improved biocompatibility of titanium–zirconium (Ti–Zr) alloy: tissue reaction and sensitization of Ti–Zr alloy compared with pure Ti and Zr in rat implantation study10.2320/matertrans.46.2260 ↗
24. A review of titanium zirconium (TiZr) alloys for use in endosseous dental implants10.3390/ma5081348 ↗
25. Electrochemical characterization of ZrTi alloys for biomedical applications10.1016/j.electacta.2012.10.026 ↗
26. XPS characterization of anodic oxides grown on biocompatible Ti–50Zr alloy in different acid electrolytes10.1002/sia.2271 ↗
27. Corrosion resistance of the Ti–50Zrat.% alloy after anodization in different acidic electrolytes10.1016/j.corsci.2010.08.021 ↗
28. Chemical reactions at surfaces: titanium oxidation10.1016/S0257-8972(99)00420-X ↗
29. Corrosion evaluation of Ti–48Al–2Cr–2Nb (at.%) in Ringer's solution10.1016/j.actbio.2006.05.012 ↗
30. Electrochemical characterization of ZrTi alloys for biomedical applications. Part 2. The effect of thermal oxidation10.1016/j.electacta.2013.05.093 ↗
31. Low carbon content NiTi shape memory alloy produced by electron beam melting10.1590/S1516-14392004000200008 ↗
32. Manufacturing and processing of NiTi implants: a review10.1016/j.pmatsci.2011.11.001 ↗
33. Yeum · 2001
34. Jones · 1996 · 62
35. Characterization of the localized surface chemical activity of Ti–Mo and Ti–Ta alloys for biomedical applications using scanning electrochemical microscopy10.1016/S1452-3981(23)15793-2 ↗