journal article·2017-12

Corrosion anisotropy of titanium deformed by the hydrostatic extrusion

A. Chojnacka, J. Kawalko, H. Koscielny, J. Guspiel, A. Drewienkiewicz, M. Bieda, W. Pachla, M. Kulczyk, K. Sztwiertnia, E. Beltowska-Lehman

Publisher page

Abstract

Abstract The corrosion behaviour of titanium rods deformed by hydrostatic extrusion (HE) in artificial saliva (Carter-Brugirard’s solution of pH 7.6) was investigated using open-circuit potentials (OCPs), (DC) potentiodynamic polarisation curves and (AC) electrochemical impedance spectroscopy (EIS) techniques. Various electrochemical parameters (corrosion potential Ecorr, corrosion current (icorr), polarisation resistance Rp, charge transfer resistance Rct and oxide film resistance Rf) were analysed. Significant coherence was observed between results achieved from these procedures, i.e., all applied techniques showed the same trend for corrosion resistance. The obtained electrochemical data were then related to the microstructure parameters (crystallographic texture, grain size, grain boundary distribution and density) determined using the EBSD/SEM technique. It was found that the corrosion behaviour of titanium processed by the HE method was superior compared to the unprocessed Ti, and this was clearly dependent on the extrusion direction. The highest corrosion resistance was revealed for the HE-deformed Ti rod of the surface oriented longitudinal (parallel) to the extrusion direction.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Titanium Alloys Microstructure and Properties · Corrosion Behavior and Inhibition · Hydrogen embrittlement and corrosion behaviors in metals

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (25)

Show source-provided references
1. Misch · 2014
2. Electrochemical corrosion behavior of Dental/Implant alloys in artificial saliva10.1007/s11665-008-9198-4 ↗
3. Titanium: the implant material of today10.1007/BF01133326 ↗
4. Titanium alloys for biomedical applications10.1016/j.msec.2005.08.032 ↗
5. Corrosion behaviour of ultra fine grained titanium in simulated body fluid for implant application
6. Corrosion resistance of ultra fine-grained Ti10.1016/j.scriptamat.2004.04.011 ↗
7. Mechanical properties of ultra-fine grain titanium
8. Microstructure and properties of pure Ti processed by ECAP and cold extrusion10.1016/S0921-5093(00)01884-0 ↗
9. Advanced mechanical properties of pure titanium with ultrafine grained structure10.1016/S1359-6462(01)01089-2 ↗
10. Corrosion characterization of titanium alloys by electrochemical techniques10.1016/j.electacta.2005.02.121 ↗
11. Corrosion behavior of novel Ti-24Nb-4Zr-7.9Sn alloy for dental implant applications in vitro10.1002/jbm.b.32838 ↗
12. Corrosion resistance and corrosion fatigue strength of new titanium alloys for medical implants without V and Al10.1016/0921-5093(96)10247-1 ↗
13. The equal channel angular extrusion process for materials processing10.1016/S1044-5803(97)80018-6 ↗
14. Electrochemical and cellular behaviour of ultrafine-grained titanium in vitro10.1016/j.msec.2014.03.001 ↗
15. Nanocrystalline titanium produced by hydrostatic extrusion10.1016/j.jmatprotec.2007.11.103 ↗
16. Microstructure of titanium deformed by warm extrusion with forward-backward rotating die10.1088/1757-899X/63/1/012012 ↗
17. Effect of severe plastic deformation realized by hydrostatic extrusion and rotary swaging on the properties of CP Ti grade 210.1016/j.jmatprotec.2015.02.027 ↗
18. Z. Machynia, K. Koynov, K. Sztwiertnia, Dental implant-distractor (ID), Patent No. P.416 895.
19. Interpretation of open circuit potential of two titanium alloys for a long time immersion in physiological fluid
20. Comparative effect of grain size and texture on the corrosion behaviour of commercially pure titanium processed by equal channel angular pressing10.1016/j.corsci.2009.08.017 ↗
21. Enhancement of biocompatibility of 316LVM stainless steel by cyclic potentiodynamic passivation10.1002/jbm.a.32053 ↗
22. Electrochemical corrosion behavior of Dental/Implant alloys in artificial saliva10.1007/s11665-008-9198-4 ↗
23. Corrosion resistance of nanostructured titanium10.1016/j.bioeng.2007.08.007 ↗
24. Electrochemical behavior of near-beta titanium biomedical alloys in phosphate buffer saline solution10.1016/j.msec.2014.11.036 ↗
25. Characterization of Ni, NiMo, NiW and NiFe electroactive coatings as electrocatalysts for hydrogen evolution in an acidic medium10.1016/j.molcata.2004.10.029 ↗