journal article·2019-04Open access

A new route to biocompatible Nitinol based on a rapid treatment with H2/O2 gaseous plasma

Monika Jenko, Matjaž Godec, Aleksandra Kocijan, Rebeka Rudolf, Drago Dolinar, Maja Ovsenik, Matevž Gorenšek, Rok Zaplotnik, Miran Mozetic

Abstract

Samples of Nitinol were oxidized using different procedures in order to improve their biocompatibility and prevent the release of Ni. The evolution of the surface oxide films was monitored using Auger electron spectroscopy (AES). The only procedure that led to the formation of nickel-free oxide films involved a pre-treatment with hydrogen plasma for 10 s followed by a treatment with a plasma composed of 90% H2 and 10% O2. Optical emission spectroscopy revealed an extremely high dissociation fraction for both the hydrogen and oxygen molecules at a discharge power of 600 W, where the luminous plasma was concentrated in a volume of about 0.1 dm3. The extreme chemical reactivity of such a plasma resulted in the formation of an oxide film in about 15 s, meaning that external oxidation took place. The biocompatibility investigations, performed according to the ISO standard protocol using L929 cells, showed the absence of any cytotoxic effects that might be due to a contact between the biological materials and nickel. The investigation of nickel release of samples exposed to Hank’s solution, measured by ICP-OES showed negligible Ni concentrations.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: MXene and MAX Phase Materials · Bone Tissue Engineering Materials · Metal and Thin Film Mechanics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (38)

Show source-provided references
1. Surface characterization of NiTi modified by plasma source ion implantation10.1016/S1359-6454(02)00251-3 ↗
2. A new look at biomedical Ti-based shape memory alloys10.1016/j.actbio.2012.01.018 ↗
3. Stability of Ni in nitinol oxide surfaces10.1016/j.actbio.2010.09.009 ↗
4. Critical overview of Nitinol surfaces and their modifications for medical applications10.1016/j.actbio.2008.01.013 ↗
5. Surface oxidation of NiTi shape memory alloy in a boiling aqueous solution containing hydrogen peroxide10.1016/j.msea.2005.11.010 ↗
6. Surface conditions of Nitinol wires, tubing, and as-cast alloys. The effect of chemical etching, aging in boiling water, and heat treatment10.1002/jbm.b.10001 ↗
7. Development of biomimetic NiTi alloy: influence of thermo-chemical treatment on the physical, mechanical and biological behavior
8. Effect of modification of oxide layer on NiTi stent corrosion resistance (vol 43, pg 433, 1998)10.1002/(SICI)1097-4636(1999)48:1<96::AID-JBM18>3.0.CO;2-W ↗
9. The corrosion and nickel release behavior of laser surface-melted NiTi shape memory alloy in Hanks, solution10.1016/j.surfcoat.2004.06.033 ↗
10. Influence of nitinol wire surface treatment on oxide thickness and composition and its subsequent effect on corrosion resistance and nickel ion release10.1002/jbm.a.30720 ↗
11. Electrochemical and surface characterization of a nickel-titanium alloy10.1016/S0142-9612(97)00210-X ↗
12. Characterization of bioactive surface oxidation layer on NiTi alloy10.1016/j.apsusc.2005.03.207 ↗
13. Surface oxidation of NiTi shape memory alloy10.1016/S0142-9612(02)00244-2 ↗
14. Oxidation behavior of TiNi shape memory alloy at 450–750 degrees C10.1016/S0921-5093(03)00287-9 ↗
15. Surface oxidation of NiTi during thermal exposure in flowing argon environment10.1016/j.matdes.2017.11.061 ↗
16. New oxidation treatment of NiTi shape memory alloys to obtain Ni-free surfaces and to improve biocompatibility10.1002/jbm.b.30441 ↗
17. Surface conditioning of nickel-titanium alloy stents for improving biocompatibility10.1179/026708401322911356 ↗
18. Formation of titanium oxide coatings on NiTi shape memory alloys by selective oxidation10.1016/j.msea.2007.02.151 ↗
19. In vivo aging of orthodontic alloys: implications for corrosion potential, nickel release, and biocompatibility
20. Corrosion, fatigue and corrosion fatigue behaviour of metal implant materials, especially titanium alloys10.1016/j.ijfatigue.2009.09.009 ↗
21. Surface structure and properties of biomedical NiTi shape memory alloy after Fenton’s oxidation10.1016/j.actbio.2007.03.002 ↗
22. Characterisation of surface-modified nickel titanium alloys10.1016/S0921-5093(02)00818-3 ↗
23. Oxidation and diffusion-processes in Nickel-titanium oxide systems10.1016/0039-6028(93)90287-T ↗
24. Effect of nanoprecipitates on the transformation behavior and functional properties of a Ti-50.8 at.% Ni alloy with micron-sized grains10.1016/j.actamat.2014.09.018 ↗
25. R-phase transformation in NiTi alloys10.1179/1743284714Y.0000000590 ↗
26. Mechanism of oxide layer growth during annealing of NiTi10.1002/jbm.a.34133 ↗
27. Influence of long-term in vivo exposure, debris accumulation and archwire material on friction force among different types of brackets and archwires couples10.1093/ejo/cjx007 ↗
28. Mezeg · 2018
29. PEEK (polyether-ether-ketone)-coated nitinol wire: film stability for biocompatibility applications10.1016/j.apsusc.2016.07.159 ↗
30. Electrodeposition study of polypyrrole-heparin and polypyrrole-salicylate coatings on Nitinol10.1016/j.matchemphys.2018.01.065 ↗
31. Functionalized Non-vascular Nitinol Stent via Electropolymerized Polydopamine Thin Film Coating Loaded with Bortezomib Adjunct to Hyperthermia Therapy (vol 7, 2017)10.1038/s41598-018-22365-y ↗
32. The effect of hydroxyapatite coatings on the passivation behavior of oxidized and unoxidized superelastic Nitinol alloys10.1007/s11665-018-3200-6 ↗
33. N. Fairley, Casa XPS VAMAS Processing software, 2018. .
34. ISO 10993-5:2009(en) Biological evaluation of medical devices — Part 5: Tests for in vitro cytotoxicity, 2009.
35. ISO 10993-5:2009(en) Biological evaluation of medical devices — Part 5: Tests for in vitro cytotoxicity, 2009.
36. Comparison of metal release from various metallic biomaterials in vitro10.1016/j.biomaterials.2004.02.005 ↗
37. ASTM G102-89(2015)e1, Standard Practice for Calculation of Corrosion Rates and Related Information from Electrochemical Measurements, 2015. .
38. Pit initiation on nitinol in simulated physiological solutions10.1002/jbm.b.33974 ↗