journal article·2013-06

Effect of aging treatment on the in vitro nickel release from porous oxide layers on NiTi

Z. Huan, L.E. Fratila-Apachitei, I. Apachitei, J. Duszczyk

Publisher page

Abstract

Abstract Despite the ability of creating porous oxide layers on nickel–titanium alloy (NiTi) surface for biofunctionalization, the use of plasma electrolytic oxidation (PEO) has raised concerns over the possible increased levels of Ni release. Therefore, the primary aim of this study was to investigate the effect of aging in boiling water on Ni release from porous NiTi surfaces that have been formed by the PEO process. Based on different oxidation conditions, e.g. electrolyte composition and electrical parameters, three kinds of oxide layers with various characteristics were prepared on NiTi substrate. The process was followed by aging in boiling water for different durations. The Ni release was assessed by immersion tests in phosphate buffer saline and the Ni concentration was measured using the flame atomic absorption spectrometry. The results showed that aging in boiling water can significantly reduce the Ni release from oxidized porous samples, given that the duration of the treatment is finely adjusted according to the parameters of the as-formed oxide layer. Surface examination of the samples before and after aging in boiling water suggested that such a treatment is non-destructive while improving the corrosion resistance of oxidized samples, as evidenced by potentiodynamic polarization tests. The results of this study indicate that water boiling may be a suitable post-treatment required to minimize Ni release from porous oxides produced on NiTi by PEO for biomedical applications.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (25)

Show source-provided references
1. Medical and dental applications of shape memory alloys
2. Shape memory alloys
3. High voltage pulse anodization of a NiTi shape memory alloy10.1149/1.2720768 ↗
4. Microstructure and corrosion resistance behavior of ceramic coatings on biomedical NiTi alloy prepared by micro-arc oxidation10.1016/j.apsusc.2008.04.068 ↗
5. Porous NiTi surfaces for biomedical applications10.1016/j.apsusc.2012.02.002 ↗
6. Preparation and properties of titanium oxide film on NiTi alloy by micro-arc oxidation10.1016/j.apsusc.2011.01.047 ↗
7. Anodic plasma-chemical treatment of CP titanium surfaces for biomedical applications10.1016/S0142-9612(03)00560-X ↗
8. In vitro antibacterial activity of porous TiO2-nano Ag composite coatings against methicillin resistant S. Aureus10.1016/j.actbio.2009.05.010 ↗
9. Surface modification of titanium, titanium alloys, and related materials for biomedical applications10.1016/j.mser.2004.11.001 ↗
10. Surface preparation of bioactive Ni–Ti alloy using alkaline, thermal treatments and spark oxidation10.1007/s10856-008-3374-9 ↗
11. The influence of surface oxides on distribution and release of nickel from Nitinol wires10.1016/j.biomaterials.2008.10.014 ↗
12. Surface conditions of Nitinol wires, tubing, and as-cast alloys: the effect of chemical etching, aging in boiling water, and heat treatment10.1002/jbm.b.10001 ↗
13. New oxidation treatment of NiTi shape memory alloys to obtain Ni-free surfaces and improve biocompatibility10.1002/jbm.b.30441 ↗
14. Critical overview of Nitinol surfaces and their modifications for medical applications10.1016/j.actbio.2008.01.013 ↗
15. Effect of heat treatment on corrosion properties of mixed sol gel silica-titania (7-3) coating10.1016/j.jnoncrysol.2010.11.027 ↗
16. Porous TiO2 surface formed on nickel–titanium alloy by plasma electrolytic oxidation: a prospective polymer-free reservoir for drug eluting stent applications10.1002/jbm.b.32872 ↗
17. Drug release from PLGA microspheres attached to solids using supercritical CO210.1177/0885328209354365 ↗
18. Formation of Al2O3 coatings on NiTi alloy by micro-arc oxidation method10.1016/j.cap.2008.06.003 ↗
19. Effects of surface treatment on the surface chemistry of NiTi alloy for biomedical applications10.1002/(SICI)1096-9918(199806)26:7<483::AID-SIA388>3.0.CO;2-5 ↗
20. XPS characterization of surface modified Ni–Ti shape memory alloy10.1016/S0921-5093(96)10563-3 ↗
21. Surface spectroscopic characterization of TiNi nearly equiatomic shape memory alloys for implants10.1116/1.579461 ↗
22. Structure and surface of NiTi human implants10.1016/S0142-9612(00)00404-X ↗
23. ToxGuideTM for Nickel. CAS# 744-02-0, U.S. Department of Health and Human Services, Agency for Toxic Substances and Disease Registry, 2005.
24. Assessment of corrosion resistance and metal ion leaching of Nitinol alloys10.1007/s11665-011-9892-5 ↗
25. Susceptibility of nitinol to localized corrosion10.1002/jbm.a.30584 ↗