Abstract This study investigated the surface characteristics and in vitro biocompatibility of a titanium (Ti) oxide layer incorporating the manganese ions (Mn) obtained by hydrothermal treatment with the expectation of utilizing potent integrin–ligand binding enhancement effect of Mn for future applications as an endosseous implant surface. The surface characteristics were evaluated by scanning electron microscopy, thin-film X-ray diffractometry, X-ray photoelectron spectroscopy, optical profilometry and inductively coupled plasma-atomic emission spectroscopy (ICP-AES). The in vitro biocompatibility of the Mn-containing Ti oxide surface was evaluated in comparison with untreated bare Ti using a mouse calvaria-derived osteoblastic cell line (MC3T3-E1). The hydrothermal treatment produced a nanostructured Mn-incorporated Ti oxide layer approximately 0.6 μm thick. ICP-AES analysis demonstrated that the Mn ions were released from the hydrothermally treated surface into the solution. Mn incorporation notably decreased cellular attachment, spreading, proliferation, alkaline phosphatase activity, and osteoblast phenotype gene expression compared with the bare Ti surface ( p 0.05). The results indicate that the Mn-incorporation into the surface Ti oxide layer has no evident beneficial effects on osteoblastic cell function, but instead, actually impaired cell behavior.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Bone and Dental Protein Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (37)

Show source-provided references
1. Mechanisms of magnesium-stimulated adhesion of osteoblastic cells to commonly used orthopaedic implants10.1002/jbm.10270 ↗
2. Effects of calcium ion implantation on osseointegration of surface blasted titanium alloy femoral implants in a canine total hip arthroplasty model10.1016/j.arth.2003.10.001 ↗
3. The effect of hydrofluoric acid treatment of TiO2 grit blasted titanium implants on adherent osteoblast gene expression in vitro and in vivo10.1016/j.biomaterials.2007.08.032 ↗
4. Effects of calcium ion incorporation on bone healing of Ti-6Al-4V alloy implants in rabbit tibiae10.1016/j.biomaterials.2007.04.007 ↗
5. Osteoconductivity of hydrophilic microstructured titanium implants with phosphate ion chemistry10.1016/j.actbio.2009.02.026 ↗
6. The roles of surface chemistry and topography in the strength and rate of osseointegration of titanium implants in bone10.1002/jbm.a.32041 ↗
7. Osteoblast response to magnesium ion-incorporated nanoporous titanium oxide surfaces10.1111/j.1600-0501.2010.01944.x ↗
8. Effects of calcium ion implantation on human bone cell interaction with titanium10.1016/j.biomaterials.2004.11.044 ↗
9. Regulation of integrin α5β1-fibronectin interactions by divalent cations10.1074/jbc.270.44.26270 ↗
10. Binding affinity of metal ions to the CD11b A-domain is regulated by integrin activation and ligands10.1074/jbc.M402901200 ↗
11. The bone response of oxidized bioactive and non-bioactive titanium implants10.1016/j.biomaterials.2005.04.058 ↗
12. Enhanced osteoconductivity of microstructured titanium implants (XiVE S CELLplus) by addition of surface calcium chemistry: a histomorphometric study in the rabbit femur10.1111/j.1600-0501.2009.01714.x ↗
13. Biocompatible Mn2+-doped carbonated hydroxyapatite thin films grown by pulsed laser deposition10.1002/jbm.a.30172 ↗
14. Human osteoblast response to pulsed laser deposited calcium phosphate coatings10.1016/j.biomaterials.2004.07.057 ↗
15. Biocompatible and bioactive coatings of Mn2+-doped β-tricalcium phosphate synthesized by pulsed laser deposition10.1016/j.apsusc.2007.08.053 ↗
16. The connection between metal ion affinity and ligand affinity in integrin I domains10.1016/j.bbapap.2007.06.014 ↗
17. Distinct role of β1 metal ion-dependent adhesion site (MIDAS), adjacent to MIDAS (ADMIDAS), and ligand-associated metal-binding site (LIMBS) cation-binding sites in ligand recognition by integrin α2β110.1074/jbc.M802066200 ↗
18. From manganism to manganese-induced parkinsonism: a conceptual model based on the evolution of exposure10.1007/s12017-009-8108-8 ↗
19. Risk assessment of an essential element: manganese10.1080/15287390903337118 ↗
20. Osteoblast response and osseointegration of a Ti-6Al-4V alloy implant incorporating strontium10.1016/j.actbio.2010.01.017 ↗
21. Effects of a novel calcium titanate coating on the osseointegration of blasted endosseous implants in rabbit tibiae10.1111/j.1600-0501.2006.01323.x ↗
22. Alkali- and heat-treated porous titanium for orthopedic implants10.1002/1097-4636(200102)54:2<198::AID-JBM6>3.0.CO;2-7 ↗
23. A highly water-soluble disulfonated tetrazolium salt as a chondrogenic indications for NADH as well as cell viability10.1016/S0039-9140(97)00017-9 ↗
24. Effects of calcium ion incorporation on osteoblast gene expression in MC3T3-E1 cells cultured on microstructured titanium surfaces10.1002/jbm.a.31618 ↗
25. Surface properties of silver doped titanium oxide films10.1016/S0257-8972(01)01305-6 ↗
26. Optical properties of anatase TiO2 thin films prepared by aqueous sol–gel process at low temperature10.1016/S0040-6090(01)01767-9 ↗
27. Low temperature preparation of nanocrystalline Mn2O3 via ethanol-thermal reduction of MnO210.1016/S0022-0248(03)00937-0 ↗
28. Synthesis of self-organized mixed oxide nanotubes by sonoelectrochemical anodization of Ti-8Mn alloy10.1016/j.electacta.2007.04.123 ↗
29. Activation of integrin αvβ3 regulates cell adhesion and migration to bone sialoprotein10.1006/excr.1999.4765 ↗
30. Influence of manganese ions on cellular behavior of human osteoblasts in vitro10.1016/j.bioeng.2007.08.003 ↗
31. Manganese inhibits poly(ADP-ribosyl)ation in human cells: a possible mechanism behind manganese-induced toxicity?10.1039/c0em00252f ↗
32. Development of low rigidity β-type titanium alloy for biomedical applications10.2320/matertrans.43.2970 ↗
33. Spark plasma sintering synthesis of porous nanocrystalline titanium alloys for biomedical applications10.1016/j.bioeng.2007.08.008 ↗
34. Preparation, microstructures, and cytocompatibility of TiMn alloys for biomedical applications10.1002/jbm.b.31668 ↗
35. Mechanical properties of porous titanium compacts prepared by powder sintering10.1016/j.scriptamat.2003.08.018 ↗
36. Influence of the surface structure of titanium materials on the adhesion of fibroblasts10.1016/0142-9612(96)87281-4 ↗
37. Response of MG63 osteoblast-like cells to titanium and titanium alloy is dependent on surface roughness and composition10.1016/S0142-9612(98)00144-6 ↗