journal article·2016-10

Surface analysis and electrochemistry of a robust carbon-nanofiber-based electrode platform H2O2 sensor

D. Suazo-Dávila, J. Rivera-Meléndez, J. Koehne, M. Meyyappan, C.R. Cabrera

Publisher page

Abstract

Abstract A vertically aligned carbon nanofiber-based (VACNF) electrode platform was developed for an enzymeless hydrogen peroxide sensor. Vertical nanofibers have heights on the order of 2–3 μm, and diameters that vary from 50 to 100 nm as seen by atomic force microscopy. The VACNF was grown as individual, vertically, and freestanding structures using plasma-enhanced chemical vapor deposition. The electrochemical sensor, for the hydrogen peroxide measurement in solution, showed stability and reproducibility in five consecutive calibration curves with different hydrogen peroxide concentrations over a period of 3 days. The detection limit was 66 μM. The sensitivity for hydrogen peroxide electrochemical detection was 0.0906 mA cm−2 mM−1, respectively. The sensor was also used for the measurement of hydrogen peroxide as the by-product of the reaction of cholesterol with cholesterol oxidase as a biosensor application. The sensor exhibits linear behavior in the range of 50 μM–1 mM in cholesterol concentrations. The surface analysis and electrochemistry characterization is presented.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Electrochemical sensors and biosensors · Analytical Chemistry and Sensors · Electrochemical Analysis and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (57)

Show source-provided references
1. Preliminary investigations of an amperometric oligosaccharide dehydrogenase-based electrode for the detection of glucose and some other low molecular weight saccharides10.1002/(SICI)1099-1352(199634/12)9:5/6<480::AID-JMR287>3.0.CO;2-8 ↗
2. Increased risk of bladder cancer associated with a glutathione peroxidase 1 codon 198 variant10.1097/01.ju.0000130942.40597.9d ↗
3. Can artisanal coalho cheese from Northeastern Brazil be used as a functional food?10.1016/j.foodchem.2012.06.058 ↗
4. Accuracy of determination of hydrogen peroxide by cerate oxidimetry10.1021/ac60086a016 ↗
5. Oxo[5,10,15,20-tetra(4-pyridyl)porphyrinato]titanium(IV): an ultra-high sensitivity spectrophotometric reagent for hydrogen peroxide10.1039/an9921701781 ↗
6. Peroxyoxalate chemiluminescence assay of hydrogen peroxide and glucose using 2,4,6,8-tetrathio-morpholinopyrimido [5,4-d]pyrimidine as a fluorescent component10.2116/analsci.7.709 ↗
7. Dispersed CuO nanoparticles on a silicon nanowire for improved performance of nonenzymatic H2O2 detection10.1021/am501799w ↗
8. High loading Pt nanoparticles on functionalization of carbon nanotubes for fabricating nonenzyme hydrogen peroxide sensor10.1016/j.bios.2014.03.046 ↗
9. A hydrogen peroxide sensor based on Pt@Au nanoparticles loading to polyethyleneimine functionalized carbon nanotubes10.1016/S1872-2040(14)60744-1 ↗
10. Recent advances in graphene-based nanomaterials for fabricating electrochemical hydrogen peroxide sensors
11. Modification with mesoporous platinum and poly(pyrrole-3-carboxylic acid)-based copolymer on boron-doped diamond for nonenzymatic sensing of hydrogen peroxide10.1016/j.jelechem.2016.01.026 ↗
12. Electroanalysis of hydrogen peroxide at boron doped diamond electrode modified by silver nanoparticles and haemoglobin10.1016/j.electacta.2015.07.013 ↗
13. Electrochemical detection of hydrogen peroxide at platinum-modified diamond electrodes for an application in melamine strip tests10.1016/j.diamond.2014.07.003 ↗
14. A novel nonenzymatic hydrogen peroxide sensor based on the synthesized mesoporous carbon and silver nanoparticles nanohybrid10.1016/j.snb.2014.06.096 ↗
15. Effects of microstructure of carbon nanofibers for amperometric detection of hydrogen peroxide10.1016/j.aca.2007.06.046 ↗
16. A novel and simple route to prepare a Pt nanoparticle-loaded carbon nanofiber electrode for hydrogen peroxide sensing10.1016/j.bios.2011.05.034 ↗
17. Voltammetric detection of hydrogen peroxide at carbon fiber microelectrodes10.1021/ac100536s ↗
18. Highly exposed Pt nanoparticles supported on porous graphene for electrochemical detection of hydrogen peroxide in living cells10.1016/j.bios.2015.06.042 ↗
19. Detection of hydrogen peroxide at a palladium nanoparticle-bilayer graphene hybrid-modified electrode10.1016/j.snb.2016.02.117 ↗
20. Nano-assemblies consisting of Pd/Pt nanodendrites and poly(diallyldimethylammonium chloride)-coated reduced graphene oxide on glassy carbon electrode for hydrogen peroxide sensors10.1016/j.msec.2015.09.015 ↗
21. A nonenzymatic hydrogen peroxide sensor based on Au–Ag nanotubes and chitosan film10.1016/j.jelechem.2014.09.026 ↗
22. Enzyme-free hydrogen peroxide sensor based on Au@Ag@C core-double shell nanocomposites10.1016/j.apsusc.2015.04.102 ↗
23. Au nanoparticles decorated reduced graphene oxide for the fabrication of disposable nonenzymatic hydrogen peroxide sensor10.1016/j.jelechem.2016.01.011 ↗
24. The synthesis of Au@C@Pt core-double shell nanocomposite and its application in enzyme-free hydrogen peroxide sensing
25. Synthesis of large arrays of well-aligned carbon nanotubes on glass10.1126/science.282.5391.1105 ↗
26. Three-dimensional model and molecular mechanism of Mycobacterium tuberculosis catalase-peroxidase (KatG) and isoniazid-resistant KatG mutants10.1089/mdr.2004.10.269 ↗
27. KOH activation of carbon nanofibers10.1016/j.carbon.2004.03.006 ↗
28. Fabrication and characterization of vertically aligned carbon nanofiber electrodes for biosensing applications10.1016/j.diamond.2005.08.019 ↗
29. Label-free detection of C-reactive protein using a carbon nanofiber based biosensor10.1016/j.bios.2014.03.027 ↗
30. Vertically aligned carbon nanofiber nanoelectrode arrays: electrochemical etching and electrode reusability10.1039/c4ra01779j ↗
31. Label-free detection of C-reactive protein using a carbon nanofiber based biosensor10.1016/j.bios.2014.03.027 ↗
32. A carbon nanofiber based biosensor for simultaneous detection of dopamine and serotonin in the presence of ascorbic acid10.1016/j.bios.2012.10.080 ↗
33. An amperometric immunosensor for separation-free immunoassay of CA125 based on its covalent immobilization coupled with thionine on carbon nanofiber10.1016/j.jim.2007.01.026 ↗
34. A carbon nanofiber based biosensor for simultaneous detection of dopamine and serotonin in the presence of ascorbicacid10.1016/j.bios.2012.10.080 ↗
35. Detection of NADH and ethanol based on catalytic activity of soluble carbon nanofiber with low overpotential10.1021/ac061282+ ↗
36. Highly sensitive flow injection detection of hydrogen peroxide with high throughput using a carbon nanofiber-modified electrode10.1039/b701933e ↗
37. Carbon nanofiber-based glucose biosensor10.1021/ac060551t ↗
38. Study of carbon nanotube modified biosensor for monitoring total cholesterol in blood10.1016/j.bios.2004.09.005 ↗
39. Recent progress on graphene-based electrochemical biosensors10.1002/tcr.201500236 ↗
40. Wafer-scale fabrication of patterned carbon nanofiber nanoelectrode arrays: a route for development of multiplexed ultrasensitive disposable biosensors10.1016/j.bios.2009.02.009 ↗
41. Ultrasensitive label-free DNA analysis using an electronic chip based on carbon nanotube nanoelectrode arrays10.1088/0957-4484/14/12/001 ↗
42. Detection of ricin using a carbon nanofiber based biosensor10.1016/j.bios.2011.07.061 ↗
43. Characterization of carbon nanofiber electrode arrays using electrochemical impedance spectroscopy: effect of scaling down electrode size10.1021/nn901583u ↗
44. Glucose biosensors based on carbon nanotube nanoelectrode ensembles10.1021/nl0347233 ↗
45. Functionalizing single-walled carbon nanotube networks: effect on electrical and electrochemical properties10.1021/jp067256x ↗
46. Control of catalyst particle crystallographic orientation in vertically aligned carbon nanofiber synthesis10.1016/j.carbon.2005.12.010 ↗
47. Carbon nanotube nanoelectrode array for ultrasensitive DNA detection10.1021/nl0340677 ↗
48. X-ray photoelectron spectroscopic characterization of chemically modified electrodes used as chemical sensors and biosensors: a review10.3390/chemosensors3020070 ↗
49. Carbon nanotubes contain metal impurities which are responsible for the electrocatalysis seen at some nanotube-modified electrodes10.1002/anie.200600033 ↗
50. Effect of purification of carbon nanotubes on their electrocatalytic properties for oxygen reduction in acid solution10.1016/j.carbon.2011.05.048 ↗
51. Monitoring oxidation of multiwalled carbon nanotubes by Raman spectroscopy10.1002/jrs.1686 ↗
52. Dispersion of single walled carbon nanotubes. Comparison of different dispersing strategies for preparation of modified electrodes toward hydrogen peroxide detection10.1016/j.elecom.2006.03.028 ↗
53. A highly sensitive hydrogen peroxide amperometric sensor based on MnO2-modified vertically aligned multiwalled carbon nanotubes10.1016/j.aca.2010.06.004 ↗
54. Voltammetric detection of hydrogen peroxide at carbon fiber microelectrodes10.1021/ac100536s ↗
55. Supramolecular microfibrils of o-phenylenediamine dimers: oxidation-induced morphology change and the spontaneous formation of Ag nanoparticle decorated nanofibers10.1021/la103038m ↗
56. Electrochemical biosensing platforms using platinum nanoparticles and carbon nanotubes10.1021/ac035143t ↗
57. A novel nonenzymatic hydrogen peroxide sensor based on electrospun nitrogen-doped carbon nanoparticles-embedded carbon nanofibers film10.1016/j.snb.2015.10.033 ↗