A comparative study of surface characterization and corrosion performance properties of laser surface modified biomedical grade nitinol
Source abstract
Abstract
Abstract Laser melting and quick solidification of shape memory alloy surfaces promise to explore the multifunctional capabilities required for enhanced biocompatibility of different implantable medical devices. Before subsequent bio-trial, understanding of the effect of cooling rate vis-a-vis laser fluence on surface characteristics and corrosion protection performance is essential before designing a tailor-made biocompatible surface for various implantable devices. The current study systematically investigates the effect of laser fluence on physical, mechanical and chemical surface characteristics along with corrosion protection performance of the modified surface as compared to bare Nitinol surface. Various phases were prominent on the top surface, namely nickel and titanium-rich phase along with different nickel-titanium intermetallics and nano-structure of titanium oxide, based on varying melting pool recirculation time and cooling rate with laser fluence energy. At low laser fluence up to 4 J/mm2, no significant melting pool were formed and only transformation to the martensitic phase of Nitinol took place on the top surface, which seemed to be highly too much corrosion-prone under simulated body fluid. At moderate laser fluence of 6–8 J/mm2, mostly titanium-rich phases are prominent on the surfaces on account of optimum recirculation of melting pool and subsequent surfacing out of comparably light phase of titanium. Titanium-rich phases on top surface exhibit superior corrosion resistance as compared to all other samples including bare nitinol. However, titanium oxide nano-particles-reinforced martensitic structure is formed under high laser fluence due to over recirculation of molten pool. The modulus of elasticity also varied from 10 to 110 GPa based on top surface formation under different fluence levels, and thus this process can act as a tailor-made controllable pre-treatment process over the traditional coating processes.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Shape Memory Alloy Transformations · Titanium Alloys Microstructure and Properties · Bone Tissue Engineering Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (32)
Show source-provided references
1. A review of shape memory alloy research, applications and opportunities10.1016/j.matdes.2013.11.084 ↗
2. An overview of Nitinol medical device applications10.1016/S0921-5093(99)00294-4 ↗
3. Instruments based on shape-memory alloy properties for minimal access surgery, interventional radiology and flexible endoscopy10.3109/13645700009063055 ↗
4. Laser welding of NiTi orthodontic archwires for selective force application10.1007/s10856-007-0164-8 ↗
5. Multiple memory shape memory alloys10.1002/adem.201200246 ↗
6. Fabrication of a novel laser-processed NiTi shape memory micro gripper with enhanced thermo mechanical functionality10.1177/1045389X12444492 ↗
7. Surface, corrosion and biocompatibility aspects of nitinol as an implant material
8. Critical overview of Nitinol surfaces and their modifications for medical applications10.1016/j.actbio.2008.01.013 ↗
9. Nickel hypersensitivity in the prosthodontics patient10.1016/0889-5406(93)70009-D ↗
10. Biocompatibility testing of Ni–Ti screw using immune histochemistry on section containing metallic implants10.1002/(SICI)1097-4636(199610)32:2<243::AID-JBM14>3.0.CO;2-K ↗
11. Electrolytic processing of NiTi shape memory alloys10.1016/j.msea.2003.11.080 ↗
12. Characterization of surface oxidation of nickel titanium alloy by ion-beam and electrochemical techniques10.1016/j.electacta.2004.07.007 ↗
13. Improvement in corrosion resistance of NiTi by anodization in acetic acid10.1016/j.matlet.2006.09.020 ↗
14. Synthesis of calcium hydrogen phosphate and hydroxyapatite coating on SS316 substrate through pulsed electrodeposition10.1016/j.msec.2016.07.044 ↗
15. Comparison of Osteoconduction, cytocompatibility and corrosion protection performance of hydroxyapatite-calcium hydrogen phosphate composite coating synthesized in-situ through pulsed electro-deposition with varying amount of phase and crystallinity10.1016/j.surfin.2017.11.002 ↗
16. Chakraborty · Surface Coat. Technol. · 2017 · 325 · 49610.1016/j.surfcoat.2017.06.073 ↗
17. Functionally graded NiTi strips prepared by laser surface anneal10.1016/j.actamat.2011.11.052 ↗
18. Electrochemical behavior of YAG laser-welded NiTi shape memory alloy10.1016/S1003-6326(06)60100-3 ↗
19. Corrosion resistance of laser spot-welded joint of NiTi wire in simulated human body fluids10.1002/jbm.a.30378 ↗
20. Corrosion properties of laser surface melted NiTi shape memory alloy10.1016/S1359-6462(01)01182-4 ↗
21. Laser welding of NiTi orthodontic arch wires for selective force application10.1007/s10856-007-0164-8 ↗
22. Effect of CO2 laser welding on the shape memory and corrosion characteristics of TiNi alloys10.1007/s11661-001-0073-2 ↗
23. Excimer laser treatment of NiTi shape memory alloy biomaterials10.1016/S0169-4332(96)00619-8 ↗
24. Corrosion behavior of a laser-welded NiTi shape memory alloy10.1016/j.matchar.2006.07.010 ↗
25. Corrosion resistance of a laser spot-welded joint of NiTi wire in simulated human body fluids10.1002/jbm.a.30378 ↗
26. Corrosion performance of medical grade NiTi after laser processing10.1016/j.surfcoat.2017.05.092 ↗
27. Susceptibility to stress corrosion cracking of NiTi laser weldment in Hanks' solution10.1016/j.corsci.2011.12.010 ↗
28. Effect of post-weld heat-treatment on the oxide film and corrosion behavior of laser-welded shape memory NiTi wires10.1016/j.corsci.2011.11.020 ↗
29. Biocompatibility of shape memory alloys
30. Surface conditions of Nitinol wires, tubing, and as-cast alloys: the effect of chemical etching, aging in boiling water, and heat treatment10.1002/jbm.b.10001 ↗
31. Surface characterizations of laser modified biomedical grade NiTi shape memory alloys10.1016/j.msec.2015.01.085 ↗
32. Effect of surface treatment of NiTi alloy on its corrosion behaviour in Hanks’ solution10.1002/jbm.10114 ↗