journal article·2019-10

Surface characteristics, Ni ion release, and antibacterial efficacy of anodized NiTi alloy using HNO3 electrolyte of various concentrations

Naofumi Ohtsu, Yuma Hirano, Kaho Yamaguchi, Kako Yamasaki

Publisher page

Abstract

Abstract A titanium oxide layer containing a small amount of Ni can be formed on a NiTi surface through anodization when using HNO 3 as an electrolyte. In this study, the effect of different HNO 3 concentrations on the surface characteristics of the alloy, including hydrophilicity, Ni-ion release, and antibacterial efficacy, was investigated. An oxide layer was fabricated, in which tiny pores were generated by pitting corrosion. The layer thickness and pore size varied with the concentration of the HNO 3 electrolyte. The hydrophilicity of the NiTi surface was dramatically improved through anodization owing to the formation of the oxide layer. The layer formed was expected to serve as a corrosion protection barrier; however, the Ni release rate from the anodized surface was higher than that of an untreated surface due to the generation of pores. The Ni release rate from the anodized surfaces varied depending on the electrolyte concentrations used, owing to the balance between the layer thickness and pore size. Ni ion release was advantageous from the view of antibacterial efficacies; the efficacies of NiTi alloy against E. coli and S. aureus were actually enhanced by anodization. Ni ion release was not beneficial with regards to allergenic reaction and cytotoxicity; the Ni ion release rate decreased rapidly when the alloy was soaked in a simulated body fluid. Thus, we concluded that anodization in HNO 3 is one possible approach to fabricate ideal NiTi medical devices with excellent antibacterial performance and biosafety.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Anodic Oxide Films and Nanostructures · Shape Memory Alloy Transformations · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (20)

Show source-provided references
1. Transformation pseudoelasticity and deformation and deformation behavior in a Ti-50.6 at% Ni alloy10.1016/0036-9748(81)90346-X ↗
2. Characteristics of deformation and transformation pseudoelasticity in Ti-Ni alloys
3. On the nature of the biocompatibility and on medical applications of NiTi shape memory and superelastic alloys10.3233/BME-1996-6405 ↗
4. A new look at biomedical Ti-based shape memory alloys10.1016/j.actbio.2012.01.018 ↗
5. Nickel ion releace from orthodontic NiTi wires under simulation of realistic in-situ conditions10.1007/s10853-005-0448-7 ↗
6. The corrosion and nickel release behavior of laser surface-melted NiTi shape memory alloys in Hanks solution10.1016/j.surfcoat.2004.06.033 ↗
7. Y. Miyano, K. Koyama, S. Kurissery, N. Kanavillil, Y. Sato, Y. Kukuchi, Anchibacterial properties of nine pure metals: a laboratory study using Staphylococcus aureus and Escherichia coli, Biofouling 26 (2010) 851–858.10.1080/08927014.2010.527000 ↗
8. Antibacterial activity of heavy metal-loaded natural zeolite10.1016/j.jhazmat.2011.11.079 ↗
9. Electrolyte effects on the surface chemistry and cellular response of anodized titanium10.1016/j.apsusc.2015.05.046 ↗
11. Characterization of surface oxidation of nickel-titanium alloy by ion-beam and electrochemical techniques10.1016/j.electacta.2004.07.007 ↗
12. Surface conditions of nitinol wires, tubing, and as-cast alloys: the effect of chemical etching, aging in boiling water, and heat treatment10.1002/jbm.b.10001 ↗
13. New oxidation treatment of NiTi shape memory alloys to obtain Ni-free surfaces and to improve biocompatibility10.1002/jbm.b.30441 ↗
14. The corrosion and nickel release behavior of laser surface-melted NiTi shape memory alloy in Hanks, solution10.1016/j.surfcoat.2004.06.033 ↗
15. Critical overview of nitinol surfaces and their modifications for medical applications10.1016/j.actbio.2008.01.013 ↗
16. Improvement in corrosion resistance of NiTi by anodization in acetic acid10.1016/j.matlet.2006.09.020 ↗
17. Microstructual characterization of oxide film formed on NiTi by anodization in acetic acid10.1016/j.jallcom.2006.08.020 ↗
18. Comparison of NiTi alloy surfaces formed by anodization in nitric, phosphoric, and sulfuric acid electrolytes10.1016/j.surfcoat.2017.12.050 ↗
19. Growth of oxide layers on NiTi alloy surfaces through anodization in nitric acid electrolyte10.1016/j.surfcoat.2017.06.021 ↗
20. Antibacterial effect of nickel-titanium alloy owing to nickel ion release10.1016/j.apsusc.2017.02.037 ↗