Ultra-precise surface processing of LYSO scintillator crystals for Positron Emission Tomography
Source abstract
Abstract
The Lutetium-Yttrium Oxyorthosilicate (LYSO) is one of the most widely used scintillation crystal in the high-performance Positron Emission Tomography (PET) systems. The quality of the surface finish of the LYSO has an important impact on the light output, the decoding performance, the energy resolution and timing resolution of the PET detectors and systems. In this paper, we present an ultra-precise method for processing the surface of LYSO crystals. The hardness and elastic modulus of the crystals were initially measured using Nano indentation technology. The scintillators were fixed onto the plate in sparse, serried and continuous arrangements and polished using an alumina (Al2O3) and cerium oxide (CeO2) polishing solution with particles of varying size. We used a magnetorheological-polishing technique to polish the LYSO crystals. The polishing solution here included hydroxyl iron powder and hard abrasives. The hardness and elastic modulus of the crystals in question was, respectively, 11.18 ± 0.50 and 155.78 ± 4gigapascals (GPa). A 3D optical surface profiler (3D-OPS) and an atomic force microscope (AFM) were used to evaluate the quality of the polished surfaces. The average roughness of Ra 0.55 nm measured by 3D-OPS was achieved using a precise plate grinding and polishing technique. The magnetorheological-polishing method also obtained an excellent roughness of Ra 0.75 nm (3D-OPS). Our report of the use of these processing technologies can serve as a foundation for further in-depth research regarding the optimal techniques for scintillator surface processing.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Radiation Detection and Scintillator Technologies · Medical Imaging Techniques and Applications · Nuclear Physics and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. A proof-of-concept study analyzing the clinical utility of fluorine-18-sodium fluoride PET-CT in skeletal staging of oncology patients with end-stage renal disease on dialysis10.1097/MNM.0000000000000759 ↗
2. Potential applications of PET/MR imaging in cardiology10.2967/jnumed.113.129262 ↗
3. PET imaging in neurology: Alzheimer's and Parkinson's diseases10.1097/MNM.0000000000000320 ↗
4. Impact of PET/CT system, reconstruction protocol, data analysis method, and repositioning on PET/CT precision: an experimental evaluation using an oncology and brain phantom10.1002/mp.12623 ↗
5. Simultaneous positron emission tomography and ultrafast ultrasound for hybrid molecular, anatomical and functional imaging10.1038/s41551-018-0188-z ↗
6. Development of novel scintillator crystals10.1016/j.jcrysgro.2006.04.048 ↗
7. Development of new scintillators for medical applications10.1016/j.nima.2015.08.041 ↗
8. Properties of LYSO and recent LSO scintillators for phoswich PET detectors10.1109/TNS.2004.829781 ↗
9. Simulation study of light transport in laser-processed LYSO: Ce detectors with single-side readout10.1088/1361-6560/aa8dea ↗
10. Development of broad-band high-reflectivity multilayer film for positron emission tomography system10.1088/1748-0221/13/09/P09016 ↗
11. Choice of crystal surface finishing for a dual-ended readout depth-of-interaction (DOI) detector10.1088/0031-9155/61/3/1041 ↗
12. Dual APD array readout of LSO crystals: optimization of crystal surface treatment10.1109/TNS.2002.1039544 ↗
13. Performance of a high-resolution depth-encoding PET detector module using linearly-graded SiPM arrays10.1088/1361-6560/aaa707 ↗
14. A gamma-photon detector based on liquid light guide for whole-body PET10.1088/1748-0221/12/11/P11012 ↗
15. Effects of reflector and crystal surface on the performance of a depth-encoding PET detector with dual-ended readout10.1118/1.4881097 ↗
16. Validation of detect 2000-based PetDetSim by simulated and measured light output of scintillator crystal pins for PET detectors10.1109/TNS.2010.2056929 ↗
17. Quality of a 28 cm long LYSO crystal and progress on optical and scintillation properties10.1109/TNS.2012.2184302 ↗
18. Measurement of ultimate tensile strength and Young modulus in LYSO scintillating crystals10.1016/j.nima.2011.07.023 ↗
19. Subsurface damage in grinding of brittle materials considering machining parameters and spindle dynamics10.1007/s00170-018-2191-7 ↗
20. Subsurface damages beneath fracture pits of reaction-bonded silicon carbide after ultra-precision grinding10.1016/j.apsusc.2018.04.038 ↗
21. Development of a practical ultrasonic vibration cutting tool system10.1016/S0924-0136(01)00649-5 ↗
22. A study on ultrasonic vibration cutting of low alloy steel
23. Review of vibration-assisted machining10.1016/j.precisioneng.2007.08.003 ↗
24. Structural, mechanical and light yield characterisation of heat treated LYSO: Ce single crystals for medical imaging applications10.1016/j.nima.2015.02.061 ↗
25. Measurement of hardness and elastic modulus by instrumented indentation: advances in understanding and refinements to methodology10.1557/jmr.2004.19.1.3 ↗
26. A review of nanoindentation continuous stiffness measurement technique and its applications10.1016/S1044-5803(02)00192-4 ↗
27. Measurement of mechanical properties by ultra-low load indentation10.1016/S0921-5093(98)00724-2 ↗
28. Ferromagnetism as a universal feature of nanoparticles of the otherwise nonmagnetic oxides10.1103/PhysRevB.74.161306 ↗
29. Fundamentals of magnetorheological fluid utilization in high precision finishing10.1106/011M-CJ25-64QC-F3A6 ↗
30. Magnetic field assisted abrasive based micro-/nano-finishing10.1016/j.jmatprotec.2009.08.015 ↗