NiTi shape-memory alloy oxidized in low-temperature plasma with carbon coating: Characteristic and a potential for cardiovascular applications
Source abstract
Abstract
Abstract Surface layers currently produced on NiTi alloys do not meet all the requirements for materials intended for use in cardiology. Plasma surface treatments of titanium and its alloys under glow discharge conditions make it possible to produce surface layers, such as TiN or TiO2, which increases corrosion resistance and biocompatibility. The production of layers on NiTi alloys with the same properties, and maintaining their shape memory and superelasticity features, requires the use of low-temperature processes. At the same time, since it is known that the carbon-based layers could prevent excessive adhesion and aggregation of platelets, we examined the composite a-CNH + TiO2 type surface layer produced by means of a hybrid method combining oxidation in low-temperature plasma and Radio Frequency Chemical Vapor Deposition (RFCVD) processes. Investigations have shown that this composite layer increases the corrosion resistance of the material, and both the low degree of roughness and the chemical composition of the surface produced lead to decreased platelet adhesion and aggregation and proper endothelialization, which could extend the range of applications of NiTi shape memory alloys.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Shape Memory Alloy Transformations · Metal and Thin Film Mechanics · Titanium Alloys Microstructure and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (42)
Show source-provided references
1. BBC Research Smart materials and their applications: Technologies and global markets. http://www.bccresearch.com/market-research/advanced-materials/smart-materials-applications-technologies-markets-report-avm023e.html, 2015 (accessed 14.10.2016).
2. A new look at biomedical Ti-based shape memory alloys10.1016/j.actbio.2012.01.018 ↗
3. Yoneyama · 2008
4. An overview of nitinol medical applications10.1016/S0921-5093(99)00294-4 ↗
5. Medical shape memory alloy applications – the market and its products10.1016/j.msea.2003.10.326 ↗
6. Manufacturing and processing of NiTi implants: a review10.1016/j.pmatsci.2011.11.001 ↗
7. Cytotoxic, allergic and genotoxic activity of a nickel-titanium alloy10.1016/S0142-9612(97)00041-0 ↗
8. Assessing the biocompatibility of NiTi shape memory alloys used for medical applications10.1007/s00216-004-2888-3 ↗
9. Biocompatibility and hemocompatibility of surface-modified NiTi alloys10.1002/jbm.a.10549 ↗
10. Nickel essentiality toxicity, and carcinogenicity10.1016/S1040-8428(01)00214-1 ↗
11. Biocompatible, smooth, plasma-treated nickel-titanium surface –an adequate platform for cell growth10.1177/0885328211416023 ↗
12. Surface characterization of NiTi modified by plasma source ion implantation10.1016/S1359-6454(02)00251-3 ↗
13. Studies of surface modified NiTi alloy10.1016/j.apsusc.2004.05.273 ↗
14. Surface oxidation of NiTi shape memory alloy10.1016/S0142-9612(02)00244-2 ↗
15. New oxidation treatment of NiTi shape memory alloys to obtainNi-free surfaces and to improve biocompatibility10.1002/jbm.b.30441 ↗
16. Critical overview of nitinol surfaces and their modification for medical applications10.1016/j.actbio.2008.01.013 ↗
17. Structure and properties of nitrided surface layer produced on NiTi shape memory alloys by low temperature plasma nitriding10.1016/j.apsusc.2014.07.109 ↗
18. Structure of low temperature nitrided/oxidized layer formed on NiTi shape memory alloy10.4028/www.scientific.net/SSP.163.127 ↗
19. Microstructure and biocompatibility of titanium oxides produced on nitrided surface layer under glow discharge conditions10.1166/jnn.2011.3474 ↗
20. In vitro studies on the influence of surface modification of Ni-Ti alloy on human bone cells10.1002/jbm.a.32646 ↗
21. TiN coating improves the corrosion behavior of superelastic NiTi surgical alloy10.1016/S0257-8972(01)01356-1 ↗
22. Corrosion and cell adhesion behavior of TiN-coated and ion-nitrided titanium for dental applications10.1016/j.apsusc.2004.10.144 ↗
23. Haemocompatibility of DLC and TiC–TiN interlayers on titanium10.1016/S0925-9635(98)00426-9 ↗
24. AFM study of the thrombogenicity of carbon-based coatings for cardiovascular applications10.1016/j.mseb.2008.06.013 ↗
25. Haemocompatibility of carbon based thin films10.1016/j.diamond.2007.05.012 ↗
26. Structure and properties of carbon coating on polyetheretherketone using RFCVD process
27. Platelet shape change and cytoskeletal reorganization on polyurethaneureas10.1002/jbm.820230109 ↗
28. Surface, corrosion and biocompatibility aspects of Nitinol as an implant material
29. Ni ion release, osteoblast-material interactions, and hemocompatibility of hafnium-implanted NiTi alloy10.1002/jbm.b.31989 ↗
30. The electrochemical characteristics of native Nitinol surfaces10.1016/j.biomaterials.2009.03.034 ↗
31. Microstructure, nickel suppression and mechanical characteristics of electropolished and photoelectrocatalytically oxidized biomedical nickel titanium shape memory alloy10.1016/j.actbio.2009.01.046 ↗
32. Bioactivity and hemocompatibility study of amorphous hydrogenated carbon coatings produced by pulsed magnetron discharge10.1002/jbm.a.34489 ↗
33. Impact of surface electric properties of carbon-based thin films on platelets activation for nano-medical and nano-sensing applications
34. Ultrastructural characterization of surface-induced platelet activation on artificial materials by transmission electron microscopy10.1002/jemt.22172 ↗
35. Novel nanostructured biomaterials: implications for coronary stent thrombosis
36. Effects of nanotopography on the in vitro hemocompatibility of nanocrystalline diamond coatings
37. Effect of nitride surface layers with different nanotopography on platelets adhesion
38. In vitro hemocompatibility and vascular endothelial cell functionality on titania nanostructures under static and dynamic conditions for improved coronary stenting applications10.1016/j.actbio.2013.08.023 ↗
39. Proteins, platelets and blood coagulation at biomaterial interfaces10.1016/j.colsurfb.2014.09.040 ↗
40. The immobilization of recombinant human tropoelastin on metals using a plasma-activated coating to improve the biocompatibility of coronary stents10.1016/j.biomaterials.2010.07.062 ↗
41. Biological response of endothelial cells to diamond-like carbon-coated NiTi alloy J10.1002/jbm.a.33295 ↗
42. Characterization and cytocompatibility of carbon layers prepared by photo-induced chemical vapor deposition10.1016/j.tsf.2007.02.014 ↗