journal article·2014-02Open access

Design and characterisation of a new duplex surface system based on S-phase hardening and carbon-based coating for ASTM F1537 Co–Cr–Mo alloy

Xia Luo, Xiaoying Li

Abstract

Co–Cr–Mo alloys are one of the most widely used metallic biomaterials for metal-on-metal joint prostheses. However, concerns over increased revision rates mainly due to nano-sized wear debris have been raised. This study was aimed at enhancing the friction, wear and load-bearing properties of Co–Cr–Mo alloys by developing a new duplex surface system combining super hard and wear-resistant S-phase layer with self-lubricating, low-friction carbon-based coating. To this end, ASTM F1537 Co–Cr–Mo alloy surface was plasma carburised (PC) at 450 °C and then coated with a carbon-based GiC coating. The microstructures of the duplex and single treated (PC or GiC coating) Co–Cr–Mo surface systems were characterized and their mechanical, tribological and corrosion properties were evaluated. The results showed that the new duplex surface system exhibited a high load bearing capacity, a low friction coefficient, excellent wear resistance and good corrosion behaviour.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced materials and composites · Metal and Thin Film Mechanics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (22)

Show source-provided references
1. Special modes of corrosion under physiological and simulated physiological conditions10.1016/j.actbio.2007.12.003 ↗
2. Metal-on-metal hip replacements ‘high failure rate’
3. S-phase surface engineering of Fe–Cr, Co–Cr and Ni–Cr alloys10.1179/095066009X12572530170589 ↗
4. T. Bell, H., Dong, C.X. Li, Plasma surface treatment of Co–Cr biomaterial, European Patent EP 1 499 755B1 (21 May 2008).
5. Microstructural characterisation of a plasma carburised low carbon Co–Cr alloy10.1179/174329407X161564 ↗
6. Design and characterisation of an advanced duplex system based on carbon S-phase case and GiC coatings for 316LVM austenitic stainless steel10.1016/j.surfcoat.2008.10.037 ↗
7. Frictional heating of total hip implants. Part 1: measurements in patients10.1016/S0021-9290(00)00188-3 ↗
8. Surface engineering of prosthetic bearing surfaces
9. Tribological properties of graphite-like and diamond-like carbon coatings10.1016/j.triboint.2004.07.012 ↗
10. Biomedical applications of diamond-like carbon (DLC) coatings: a review10.1016/j.surfcoat.2005.07.077 ↗
11. Electrochemical corrosion behaviour of uncoated and DLC coated medical grade Co28Cr6Mo10.1016/j.surfcoat.2003.06.015 ↗
12. Biomedical applications of diamond-like carbon coatings: a review10.1002/jbm.b.30768 ↗
13. In vitro studies of the adhesion of diamond-like carbon thin films on CoCrMo biomedical implant alloy10.1016/j.actamat.2011.04.014 ↗
14. Examination of failed ex vivo metal-on-metal metatarsophalangeal prosthesis and comparison with theoretically determined lubrication regimes10.1016/j.wear.2006.11.045 ↗
15. The load bearing capacity of hydrogen-free Cr-DLC coatings on deep-case oxygen hardened Ti6Al4V10.1016/j.surfcoat.2005.06.021 ↗
16. An overview on the tribological behavior of diamond-like carbon in technical and medical applications10.1016/j.triboint.2004.07.017 ↗
17. A study of the tribological behaviour of CrN, Graphit-iC and Dymon-iC coatings under oil lubrication10.1016/j.surfcoat.2004.07.078 ↗
18. Realising the potential of duplex surface engineering10.1016/S0301-679X(98)00015-2 ↗
19. Failure modes in scratch adhesion testing10.1016/0257-8972(91)90188-3 ↗
20. EIS capacitance diagnosis of nanoporosity effect on the corrosion protection of DLC films10.1016/S0925-9635(01)00568-4 ↗
21. Effect of 3D physiological loading and motion on elastohydrodynamic lubrication of metal-on-metal total hip replacements10.1016/j.medengphy.2009.02.002 ↗
22. (iv) The science of metal-on-metal articulation10.1016/j.cuor.2005.08.002 ↗