journal article·2006-07

Characterisation of human hair surfaces by means of static ToF-SIMS: A comparison between Ga+ and C60+ primary ions

Claude Poleunis, Emmanuel P. Everaert, Arnaud Delcorte, Patrick Bertrand

Applied Surface Science· Volume 252· Issue 19
Publisher page

Abstract

This study deals with the secondary ion yield improvement induced by using C-60(+) primary ions instead of Ga+ ones to characterize human hair surfaces by ToF-SIMS. For that purpose, a bunch of hair fibres has been analysed with both ion sources. A high improvement is observed for the detection of amino acids with C-60(+) primary ions as compared to Ga+ ions. As an example, a yield enhancement factor greater than 3000 is found for the CNO- peak. A similar gain is observed for the positive secondary ions characteristic of the amino acids. Most of the atomic ions, such as Ca+, O- and S-, constitute minor peaks with C-60(+) ions while they often dominate the spectrum in the case of Ga+ ions. However, with the C-60(+) source, a series of inorganic combination peaks with the elements Ca, S and O are observed in the positive spectra (i.e. HCaSO4+), While they are marginal with the Ga+ source. For the mass range beyond 100 m/z and in both polarities, the hair fingerprints are similar with both sources. In average, for a comparable number of primary ions per spectrum, the C-60(+) ion source gives intensities between two and three orders of magnitude higher than the Ga+ one. (c) 2006 Elsevier B.V. All rights reserved.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Ion-surface interactions and analysis · Forensic Fingerprint Detection Methods · Nonlinear Optical Materials Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (15)

Show source-provided references
1. Maxwell · Micron · 2005 · 36 · 12710.1016/j.micron.2004.10.001 ↗
2. Harvay · J. Cosmet. Sci. · 2004 · 55 · 265
3. Swift · Scanning · 2000 · 22 · 31010.1002/sca.4950220506 ↗
4. Groenewold · J. Trace Microprobe Tech. · 2000 · 18 · 107
5. Kempson · Eur. J. Mass Spectrom. · 2003 · 9 · 58910.1255/ejms.584 ↗
6. Hornby · Int. Fed. Soc. Cosmet. Chem. Mag. · 2005 · 8 · 99
7. Weibel · Anal. Chem. · 2003 · 75 · 175410.1021/ac026338o ↗
8. Weibel · Appl. Surf. Sci. · 2004 · 231–232 · 14610.1016/j.apsusc.2004.03.098 ↗
9. Winograd · Anal. Chem. · 2005 · 77 · 143A10.1021/ac053355f ↗
10. Bertrand · Mikrochim. Acta · 1996 · 13 · 167
11. Briggs · Vacuum · 1986 · 36 · 100510.1016/0042-207X(86)90156-9 ↗
12. Ionoptika Limited (Ed.), IOG-C60-20 Ion Source Operating Manual 99-014 Rev. 1.0, Southampton, UK, 2004, p. 44.
13. Solomko · Appl. Surf. Sci. · 2004 · 231–232 · 4810.1016/j.apsusc.2004.03.024 ↗
14. Postawa · J. Phys. Chem. B · 2005 · 109 · 1197310.1021/jp050821w ↗
15. Delcorte · 2005