Influence of NH+ beam bombarding energy on structural characterization and cell attachment of CN coating
Source abstract
Abstract
Abstract The carbon nitride (CNx) coating with its novel properties will be excellent candidate for biomedical applications. CNx coatings were prepared on the surface of Ti–6Al–4V by ion-beam-assisted deposition (IBAD) with different NHn+ beam bombarding energies at low substrate temperature. The coatings were characterized by Scanning electron microscopy (SEM), Auger electron spectroscopy (AES), X-ray photoelectron spectroscopy (XPS), Raman spectroscopy, and Fourier-transform infrared (FTIR) spectroscopy. The result showed that the wear-resistance of CNx coatings was better at higher beam bombarding energy. The cell attachment tests also gave interesting results that CNx coatings exhibited low macrophage attachment and provide desirable surface for the normal cellular growth and morphology of the fibroblasts. Structural analysis showed that NHn+ beam bombardment at the energies of 300–400 eV could result in more nitrogen concentration and fraction of sp3CN bonds in the structure of CNx coatings, which may be responsible for the improvement in the wear-resistance and the cell attachment.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Diamond and Carbon-based Materials Research · Metal and Thin Film Mechanics · Boron and Carbon Nanomaterials Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (23)
Show source-provided references
1. Thomson · Biomaterials · 1991 · 12 · 3710.1016/0142-9612(91)90129-X ↗
2. Charnley · Clin. Orthop. · 1975 · 112 · 17010.1097/00003086-197510000-00021 ↗
3. Willert · J. Biomed. Mater. Res. · 1977 · 11 · 15710.1002/jbm.820110202 ↗
4. Goodman · Clin. Orthop. · 1989 · 244 · 18210.1097/00003086-198907000-00017 ↗
5. Murray · J. Bone Joint Surg. Br. · 1990 · 72 · 98810.1302/0301-620X.72B6.2246303 ↗
6. Ikada · Biomaterials · 1994 · 15 · 72510.1016/0142-9612(94)90025-6 ↗
7. J.R. Wolter, Biomaterials in Ophthalmology, Bologna, Academic Press 1990.
8. J.M. Courtney, S. Sundaram, C.D. Forbers, Management of Bleeding Disorders in Surgical Practice, Blackwell Scientific Publication, Oxford, 1993, p. 236.
9. Quiros · Vacuum · 1999 · 52 · 19910.1016/S0042-207X(98)00220-6 ↗
10. Su · Surf. Coat. Technol. · 1996 · 84 · 38810.1016/S0257-8972(95)02809-9 ↗
11. Song · J. Phys. Condens. Mater. · 1994 · 6 · 612510.1088/0953-8984/6/31/011 ↗
12. Fujimoto · Jpn. J. Appl. Phys. · 1993 · 32 · L42010.1143/JJAP.32.L420 ↗
13. Li · Appl. Surf. Sci. · 1999 · 137 · 3010.1016/S0169-4332(98)00485-1 ↗
14. Li · J. Adhes. Sci. Technol. · 1999 · 13 · 16910.1163/156856199X00370 ↗
15. Li · Vacuum · 2000 · 56 · 20510.1016/S0042-207X(99)00183-9 ↗
16. Cui · Surf. Coat. Technol. · 2000 · 131 · 48110.1016/S0257-8972(00)00809-4 ↗
17. Sharma · Inter. Mater. Rev. · 1994 · 42 · 13710.1179/imr.1997.42.4.137 ↗
18. Zhang · J. Electron. Mater. · 1996 · 25 · 5710.1007/BF02666174 ↗
19. Wixam · J. Am. Ceram. Soc. · 1990 · 73 · 197310.1111/j.1151-2916.1990.tb05254.x ↗
20. Scharf · J. Appl. Phys. · 1999 · 85 · 314210.1063/1.369654 ↗
21. Beeman · Phys. Rev. B · 1984 · 30 · 87010.1103/PhysRevB.30.870 ↗
22. Masao · Jpn. J. Appl. Phys. · 1997 · 36 · 231310.1143/JJAP.36.2313 ↗
23. Ronning · Phys. Rev. B · 1998 · 58 · 220710.1103/PhysRevB.58.2207 ↗