In vitro hemocompatibility and cytocompatibility of dexamethasone-eluting PLGA stent coatings
Source abstract
Abstract
Abstract Drug-eluting stents (DESs) have been an important breakthrough for interventional cardiology applications since 2002. Though successful in reducing restenosis, some adverse clinical problems still emerged, which were mostly caused by the bare-metal stents and non-biodegradable polymer coatings, associated with the delayed endothelialization process. In this study, dexamethasone-loaded poly (lactic-co-glycolic acid) (PLGA) coatings were developed to explore the potential application of dexamethasone-eluting stents. Dexamethasone-eluting PLGA stents were prepared using ultrasonic atomization spray method. For other tests like stability and cytocompatibility and hemocompatibility tests, dexamethasone loaded coatings were deposited on 316L SS wafers. Fourier transform-infrared spectroscopy (FT-IR) results demonstrated that there was no chemical reaction between PLGA and dexamethasone. The balloon expansion experiment and surface morphology observation suggested that the stent coatings were smooth and uniform, and could also withstand the compressive and tensile strains imparted without cracking after stent expansion. The drug release behavior in vitro indicated that dexamethasone existed burst release within 1 day, but it presented linear release characteristics after 6 days. In vitro platelets adhesion, activation test and APTT test were also done, which showed that after blending dexamethasone into PLGA, the hemocompatibility was improved. Besides, dexamethasone and dexamethasone-loaded PLGA coatings could significantly inhibit the attachment and proliferation of smooth muscle cells.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Coronary Interventions and Diagnostics · Electrospun Nanofibers in Biomedical Applications · Polymer Surface Interaction Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (51)
Show source-provided references
1. Coronary-artery stents10.1056/NEJMra051091 ↗
2. Approaches for prevention of restenosis10.1002/jbm.b.30974 ↗
3. Effects of curcumin for preventing restenosis in a hypercholesterolemic rabbit iliac artery stent model10.1002/ccd.22047 ↗
4. Very late stent thrombosis and late target lesion revascularization after sirolimus-eluting stent implantation: five-year outcome of the j-Cypher Registry10.1161/CIRCULATIONAHA.111.046599 ↗
5. Examination of the in vivo mechanisms of late drug-eluting stent thrombosis findings from optical coherence tomography and intravascular ultrasound imaging10.1016/j.jcin.2011.09.018 ↗
6. Late stent thrombosis: the last remaining obstacle in coronary interventional therapy10.1007/s11886-012-0283-9 ↗
7. 10-Year follow-up of the first Cypher stent implanted in human: an invasive evaluation with angiography, intravascular ultrasound, and optical coherence tomography10.1016/j.jcin.2009.12.016 ↗
8. In vitro and in vivo changes to PLGA/sirolimus coating on drug eluting stents10.1016/j.biomaterials.2010.02.003 ↗
9. Sirolimus-eluting stents for treatment of patients with long atherosclerotic lesions in small coronary arteries: double-blind, randomized controlled trial (E-SIRIUS)10.1016/S0140-6736(03)14462-5 ↗
10. Lack of neointimal proliferation after implantation of Sirolimus coated stents in human coronary arteries: a quantitative coronary angiography and 3-dimensional intravascular ultrasound study10.1161/01.CIR.103.2.192 ↗
11. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery10.1056/NEJMoa035071 ↗
12. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease10.1056/NEJMoa032441 ↗
13. Paclitaxel-coated balloon catheter versus paclitaxel-coated stent for the treatment of coronary in-stent restenosis10.1161/CIRCULATIONAHA.108.839282 ↗
14. Paclitaxel eluting balloons, paclitaxel-eluting stents, and balloon angioplasty in patients with restenosis after implantation of a drug-eluting stent (ISAR-DESIRE 3): a randomised, open-label trial10.1016/S0140-6736(12)61964-3 ↗
15. Reduction in neointimal formation with a stent coated with multiple layers of releasable heparin in porcine coronary arteries10.1097/00005344-200204000-00007 ↗
16. Heparin-immobilized polymers as non-inflammatory and non-thrombogenic coating materials for arsenic trioxide eluting stents10.1016/j.actbio.2009.07.013 ↗
17. Safety of an aspirin-alone regimen after intracoronary stenting with a heparin-coated stent: final results of the HOPE (HEPACOAT and an Antithrombotic Regimen of Aspirin Alone) study10.1161/01.CIR.0000086347.31341.F9 ↗
18. Dexamethasone-eluting stent: an antiinflammatory approach to inhibit coronary restenosis10.1586/14779072.2.5.653 ↗
19. Analysis of a phosphorylcholine-based polymer coating on a coronary stent pre- and postimplantation10.1016/S0142-9612(01)00297-6 ↗
20. Study of antirestenosis with the Biodivsysio dexamethasone eluting stent (STRIDE): a first-in-human multicenter pilot trial10.1002/ccd.10636 ↗
21. Antioxidant vitamins and their use in preventing cardiovascular disease10.3390/molecules15118098 ↗
22. A comparative study of the effects of vitamin C, sirolimus, and paclitaxel on the growth of endothelial and smooth muscle cells for cardiovascular medical device applications
23. Green tea polyphenol epigallocatechin-3 gallate induces apoptosis of proliferating vascular smooth muscle cells via activation of p5310.1096/fj.02-0665fje ↗
24. Matrix metalloproteinases and tissue inhibitors of metalloproteinases: structure, function, and biochemistry10.1161/01.RES.0000070112.80711.3D ↗
25. Matrix metalloproteinases in vascular remodeling and atherogenesis: the good, the bad, and the ugly10.1161/res.90.3.251 ↗
26. Genetic polymorphisms of matrix metalloproteinases and their inhibitors in potentially malignant and malignant lesions of the head and neck10.1186/1423-0127-17-10 ↗
27. Local intraluminal infusion of biodegradable polymeric nanoparticles-A novel approach for prolonged drug delivery after balloon angioplasty10.1161/01.CIR.94.6.1441 ↗
28. Glucocorticoids promote chondrogenic differentiation of adult human mesenchymal stem cells by enhancing expression of cartilage extracellular matrix genes10.1634/stemcells.2005-0415 ↗
29. Avoiding restenosis: is there a role for glucocorticoids in the drug-eluting stent era?10.1177/1753944708090573 ↗
30. Spatiotemporal effects of a controlled-release anti-inflammatory drug on the cellular dynamics of host response10.1016/j.biomaterials.2011.02.048 ↗
31. Molecular mechanisms of in-stent restenosis and approach to therapy with eluting stents10.1016/S1050-1738(03)00038-0 ↗
32. Evaluation of in vivo–in vitro release of dexamethasone from PLGA microspheres10.1016/j.jconrel.2008.01.004 ↗
33. In vivo evaluation of a dexamethasone/PLGA microsphere system designed to suppress the inflammatory tissue response to implantable medical devices10.1002/jbm.10016 ↗
34. Dexamethasone/PLGA microspheres for continuous delivery of an anti-inflammatory drug for implantable medical devices10.1016/S0142-9612(01)00291-5 ↗
35. Physicochemical properties of extruded and nonextruded liposomes containing the hydrophobic drug dexamethasone10.1016/j.ijpharm.2010.01.003 ↗
36. Properties of lactic acid based polymers and their correlation with composition10.1016/S0079-6700(02)00012-6 ↗
37. Biodegradable polymeric scaffolds for musculoskeletal tissue engineering10.1002/1097-4636(200105)55:2<141::AID-JBM1000>3.0.CO;2-J ↗
38. Lipase-catalysed biodegradation of poly (ɛ-caprolactone) blended with various polylactide based polymers10.1021/bm025748j ↗
39. Influence of electron beam radiation on the hydrolytic degradation behaviour of poly (lactide-co-glycolide) (PLGA)10.1016/j.biomaterials.2004.05.001 ↗
40. Effect of isothermal annealing on the hydrolytic degradation rate of poly(lactide-co-glycolide) (PLGA)10.1016/j.biomaterials.2004.08.031 ↗
41. Physical characterization of controlled release of paclitaxel from the TAXUS™ Express 2™ drug-eluting stent10.1002/jbm.a.30188 ↗
42. Influence of stent surface topography on the outcomes of patients undergoing coronary stenting: a randomized double-blind controlled trial10.1002/ccd.20400 ↗
43. Preparation of self-organized porous anodic niobium oxide microcones and their surface wettability10.1016/j.actamat.2009.04.050 ↗
44. Preparation of gelatin microspheres containing lactic acid-effect of crosslinking on drug release
45. New frontiers in cardiology, drug-eluting stents: part l10.1161/01.CIR.0000069330.41022.90 ↗
46. Thrombopoietin potentiate collagen receptor signaling in platelets through a phosphatidylinositol 3-kinase-dependent pathway10.1182/blood.V95.11.3429 ↗
47. Inhibition of coagulation and platelet adhesion to extraeellular matrix by unfractionated heparin and a low molecular weight heparin10.1007/BF01732879 ↗
48. Application of enzyme immunoassays for testing haemocompatibility of biomedical polymers10.1016/0142-9612(95)94909-5 ↗
49. Platelet-activating factor and related lipid mediators10.1146/annurev.biochem.69.1.419 ↗
50. High dose dexamethasone increases circulating P-selectin and von Willebrand factor levels in healthy men10.1160/TH04-10-0652 ↗
51. Dexamethasone inhibits the phosphorylation of retinoblastoma protein in the suppression of human vascular smooth muscle cell proliferation10.1006/jsre.2000.5942 ↗