journal article·2014-07

The stability of DLC film on nitrided CoCrMo alloy in phosphate buffer solution

T.F. Zhang, B. Liu, B.J. Wu, J. Liu, H. Sun, Y.X. Leng, N. Huang

Publisher page

Abstract

Abstract CoCrMo alloy is often used as the material for metal artificial joint, but metal debris and metal ions are the main concern on tissue inflammation or tissue proliferation for metal prosthesis. In this paper, nitrogen ion implantation and diamond like carbon (DLC) film composite treatment was used to reduce the wear and ion release of biomedical CoCrMo substrate. The mechanical properties and stability of N-implanted/DLC composite layer in phosphate buffer solution (PBS) was evaluated to explore the full potential of N-implanted/DLC composite layer as an artificial joint surface modification material. The results showed that the DLC film on N implanted CoCrMo (N-implanted/DLC composite layer) had the higher surface hardness and wear resistance than the DLC film on virgin CoCrMo alloy, which was resulted from the strengthen effect of the N implanted layer on CoCrMo alloy. After 30 days immersion in PBS, the structure of DLC film on virgin CoCrMo or on N implanted CoCrMo had no visible change. But the adhesion and corrosion resistance of DLC on N implanted CoCrMo (N-implanted/DLC composite layer) was weakened due to the dissolution of the N implanted layer after 30 days immersion in PBS. The adhesion reduction of N-implanted/DLC composite layer was adverse for in vivo application in long term. So researcher should be cautious to use N implanted layer as an inter-layer for increasing CoCrMo alloy load carrying capacity in vivo environment.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Metal and Thin Film Mechanics · Orthopaedic implants and arthroplasty · Diamond and Carbon-based Materials Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (25)

Show source-provided references
1. Lubrication and wear modelling of artificial hip joints: a review10.1016/j.triboint.2010.06.010 ↗
2. Engineering biocompatible implant surfaces
3. Comparison of wear debris generated from ultra high molecular weight polyethylene in vivo and in artificial joint simulator10.1016/j.wear.2010.11.012 ↗
4. Wear reduction effect on ultra-high-molecular-weight polyethylene by application of hard coatings and ion implantation on cobalt chromium alloy, as measured in a knee wear simulation machine10.1016/S0257-8972(01)01074-X ↗
5. Ceramic materials in total joint arthroplasty10.1053/j.sart.2006.09.002 ↗
6. An overview on diamond-like carbon coatings in medical applications10.1016/j.surfcoat.2013.04.015 ↗
7. Range of motion and stability in total hip arthroplasty with 28-, 32-, 38-, and 44-mm femoral head sizes10.1016/j.arth.2004.07.008 ↗
8. Delays and difficulties in assessing metal-on-metal hip implants10.1056/NEJMp1206794 ↗
9. Veli-Matti Tiainen, Amorphous carbon as a bio-mechanical coating—mechanical properties and biological applications. Diamond Relat. Mater. 10 (2001) 153–160.
10. The counterface, surface smoothness tolerances, and coatings in total joint prostheses10.1097/00003086-199912000-00010 ↗
11. Tribological behavior of DLC-coated articulating joint implants10.1016/j.actbio.2009.12.019 ↗
12. A review of modified DLC coatings for biological applications10.1016/S0925-9635(03)00081-5 ↗
13. Comparison of diamond-like-carbon and alumina-oxide articulating with polyethylene in total hip arthroplasty10.1002/mawe.200300717 ↗
14. Examination of failed ex vivo metal-on-metal metatarsophalangeal prosthesis and comparison with theoretically determined lubrication regimes10.1016/j.wear.2006.11.045 ↗
15. High frequency and low voltage plasma immersion ion implantation of nitrogen on industrial pure iron at different Rf power10.1016/j.surfcoat.2011.04.009 ↗
16. The microstructure and mechanical properties of multilayer diamond-like carbon films with different modulation ratios10.1016/j.apsusc.2012.10.003 ↗
17. Measurement of hardness and elastic modulus by instrumented indentation: advances in understanding and refinements to methodology10.1557/jmr.2004.19.1.3 ↗
18. In vitro studies of the adhesion of diamond-like carbon thin films on CoCrMo biomedical implant alloy10.1016/j.actamat.2011.04.014 ↗
19. Study of the biotribocorrosion behaviour of titanium biomedical alloys in simulated body fluids by electrochemical techniques10.1016/j.wear.2012.04.014 ↗
20. The composition of the surface passive film formed on CoCrMo alloy in simulated physiological solution10.1016/S0013-4686(03)00396-7 ↗
21. Orhan Öztürk, Uğur Türkan, Ahmet E. Eroğlu, Metal ion release from nitrogen ion implanted CoCrMo orthopedic implant material. Surf. Coat. Technol. 200 (2006) 5687–5697.
22. The composition of the surface passive film formed on CoCrMo alloy in simulated physiological solution10.1016/S0013-4686(03)00396-7 ↗
23. Diamond-like carbon coatings on a CoCrMo implant alloy: a detailed XPS analysis of the chemical states at the interface10.1016/j.actamat.2010.10.048 ↗
24. High-intensity plasma ion nitriding of orthopedic materials: part I. Tribological study10.1016/j.surfcoat.2004.02.052 ↗
25. Near surface analysis of duplex PIII treated CoCr alloys10.1016/j.nimb.2012.11.052 ↗