Experimental Study on Sprayed FRP System for Strengthening Reinforced Concrete Beams
Source abstract
Abstract
The purpose of this study is to develop a new technique for strengthening and repairing existing concrete structures with sprayed fiber-reinforced polymers (FRP) by mixing chopped carbon or glass fibers with epoxy or vinyl ester resins in open air and randomly spraying the mixture onto the concrete surface with compressed air. The use of sprayed FRP for repair and strengthening purposes using epoxy or vinyl ester resins has never been fully investigated. In this study, tensile testing was conducted on material specimens to determine the optimum length of chopped carbon or glass fibers and the mixture ratio of fiber, epoxy, and vinyl ester resin for sprayed FRP. These variables were adjusted to produce a material strength equivalent to that of one FRP sheet. The optimal length of glass and carbon chopped fibers was determined to be 38 mm, and the optimal mixture ratio of chopped fiber to resin was found to be 1:2. The thickness of sprayed FRP required to provide the same strengthening effect as one FRP sheet was also calculated. During this study, experiments were conducted to evaluate the strengthening/repair effects of the sprayed FRP on flexural beams, shear beams, and damaged beams. The results showed that the strengthening effect of sprayed FRP on the flexural and shear specimens was similar to those of one FRP sheet. The maximum strength of the damaged beams reinforced by sprayed FRP was approximately the same as that of the reinforced flexural and shear beams. Moreover, existing design equations for FRP sheets were found to be applicable to flexural beams reinforced with sprayed FRP. The shear beam specimens could be safely designed using the coefficient of shear strength reduction α= 0.18, determined to result in computed values that most closely approximate the experimental values. Overall, the sprayed FRP technique was found to be suitable for strengthening existing reinforced concrete buildings.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Architecture, Chonnam National University, Gwangju, 500-757, South Korea.
References (19)
Show source-provided references
1. American Concrete Institute, ACI Committee 318-05, (2005). “Building code requirements for reinforced concrete and commentary.” Farmington Hills: Michigan.
2. American Concrete Institute, ACI Committee 440, (2000). “Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures.” Farmington Hills: Michigan.
3. Baek, S. M., Kim, U. S. and Kwak, Y. K., (2004). “Experimental study of shear reinforcement effect on a structurally damaged RC beam.” Journal of Architectural Institute of Korea (Structure Series), 20(2), 47-54. (in Korean)
4. Banthia, N., Nandakumar, N. and Boyd, A., (2002). “Sprayed fiber reinforced polymers: From laboratory to a real bridge.” Concrete international: Design and Construction, 24(11), 47-52.
5. El-Mihilmy, M. T. and Tedesco, J. W., (2000). “Deflection of reinforced concrete beams strengthened with fiber reinforced polymer (FRP) plates.” ACI Structural Journal, 97(5), 679-688.
6. Furuta, T., Kanakubo, T., Nemoto, T., Takahashi, K. and Fukuyama, H., (2001a). “Sprayed up FRP strengthening for concrete structures.” In: Proceedings of International Conference on FRP Composites in Civil Engineering, 2, 1109-1116.
7. Furuta, T., Kanakubo, T., Nemoto, T., Takahashi, K., Itoh, K. and Minamihara, H., (2001b). “Sprayed up FRP strengthening for reinforced concrete beams.” In: International Conference on Composites in Infrastructure, CD-ROM No. 094.
8. Han, M. Y., (1998). “Structural behavior of a beam in response to the deformed bonding of the reinforcement material.” Journal of Korea Concrete Institute, 10(3), 129-147. (in Korean)
9. Harries, K. A. and Young, S. C., (2003). “Sprayed fiber reinforced composite materials for infrastructure rehabilitation.” Concrete international, 25(1), 47-51.
10. Japan Building Disaster Prevention Association, JBDPA, (2001). “Standard for damage level classification.” Tokyo: Japan. (in Japanese)
11. Japanese Industrial Standards, JIS K 7054, (2006). “Tensile test method for glass-fiber reinforced plastic.” Japanese Standards Association. (in Japanese)
12. Korean Industrial Standards, KS M 3381, (2004). “Tensile test method for glass-fiber reinforced plastic.” Korean Standards Association. (in Korean)
13. Lee, W. H., Im, J. Y. and Park, I. S., (2001). “Flexural reinforcement effect of carbon fiber sheet on RC beams.” Journal of Architectural Institute of Korea (Structure Series), 17(1), 11-19. (in Korean).
14. Lee, Y. T. and Lee L. H., (2000). “Investigation of shear strength of a RC beam reinforced with carbon fiber sheet.” Journal of Architectural Institute of Korea (Structure Series), 16(1), 11-17. (in Korean)
15. Nah, J. M., (2001). “Evaluation of structural performance of a RC member reinforced with carbon fiber.” PhD Dissertation, Hanyang University. (in Korean)
16. Nam, J. H., (1998). “Experimental study of the shear bearing capacity of a RC beam reinforced with carbon fiber sheet.” Master's Thesis, Hanyang University. (in Korean)
17. Shin, S. W., (1999). “Shear behavior of a RC beam reinforced with carbon fiber sheet.” Journal of Korea Structural Maintenance Institute, 2(3), 206-211. (in Korean)
18. Sin, Y. S., (1999). “Shear reinforcement effect of carbon fiber sheet on RC beams.” Journal of Architectural Institute of Korea (Structure Series), 15(9), 11-18. (in Korean)
19. Zsutty, T. C., (1986). “Beam shear strength prediction by analysis of existing data.” ACI Journal Proceedings, 65(11), 943-951.