Control of KEKB vacuum system
Source abstract
Abstract
In a vacuum system of the KEKB accelerator that is a two ring electron-positron collider, there are nearly 10,000 control points. A large number of vacuum related components should be controlled and/or monitored at the rings and the beam transport line from the linac. Those component hardwares are connected to their sub-interfaces such as ADC interfaced by devices of CAMAC, RS-232C, GP-IB, and programmable logic controller (PLC) via GP-IB. The all device interfaces are controlled with newly developed softwares based on EPICS (experimental physics industrial control system) and single board equipment control computers through a high speed network using a UNIX-based workstation with X-terminals or emulators as operator consoles. The control points of the hardware for the vacuum system have been successfully implemented for monitor, control and data acquisition after the commissioning for 8 months utilizing EPICS software.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Particle Accelerators and Free-Electron Lasers · Particle accelerators and beam dynamics · Superconducting Materials and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (3)
Show source-provided references
1. KEK Report 95-7, KEK, 1995.
2. S.A. Lewis, Lawrence Berkeley National Laboratory, http://csg.lbl.gov/EPICS/OverView.pdf (1998).
3. W. McDowell, M. Knott, M. Kraimer, Argonne National Lab, http://www.aps.anl.gov/asd/controls/epics/EpicsDocumentation/APSManuals/aps_ctls_ov.html#intro (1993).