Abstract Electrostimulation has emerged as a significant therapeutic and diagnostic tool in modern medicine, physiotherapy, and wearable healthcare technologies. Electrodes play the role of transducer between electrical signals and biological tissues, striving to provide efficacy, comfort, and biocompatibility. This article presents a detailed overview about types of electrodes have been used for electrostimulation (plain or solid fill), their fabrication based on material composition, structural design, and functional applications. It also discusses the evolution of the traditional two-dimensional electrode to the three-dimensional porous electrode structure. Porous electrodes play a significant role in electrostimulation interfaces as they have large surface area, less impedance, improved skin conformability as well as enhanced ion exchange capabilities. These properties help them to create a more uniform current distribution, reduced discomfort, and improved signal accuracy during stimulation, especially in long-term and wearable applications. Moreover, the subtypes of porous electrodes (1 conventional and 2 textrodes), along with their fabrication techniques and categories based on material composition and structural design, are also discussed. This review focuses on the material innovations and fabrication strategies leading to the development of conventional porous electrodes, including 3D printing, electrospinning, laser sintering, templating and gel casting. The various techniques used to introduce porosity in conventional porous electrodes have been comprehensively reviewed. The incorporation of porosity not only improves mechanical flexibility and breathability but also enhances the ability to load and release therapeutic agents, enabling multifunctional applications such as electroceutical wound healing and controlled drug delivery. While the textrode (a scientific notation of textile-based electrodes) being inherently porous, are discussed, its types and fabrication techniques of are also explained. Add on, a detailed analysis was made between the comparative performance of conventional and textile based porous electrodes. The article also highlights recent developments in biodegradable and sustainable porous electrode systems, aligning with the global push towards eco-friendly healthcare solutions.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Neuroscience and Neural Engineering · Planarian Biology and Electrostimulation · Advanced Sensor and Energy Harvesting Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Material Sciences , Technical University of Liberec , Liberec , 460 15 , Czech Republic
GEMTEX Textile Research Laboratory , University of Lille , France , 59000 , France
Department of Environmental Science , Lahore College for Women University , 54000 , Lahore , Pakistan
References (100+)
Show source-provided references
1. S. B. Rajendran, K. Challen, K. L. Wright, and J. G. Hardy, “Electrical stimulation to enhance wound healing,” J. Funct. Biomater., vol. 12, no. 2, p. 40, 2021, https://doi.org/10.3390/JFB12020040.10.3390/jfb12020040 ↗
2. X. F. Teng, C. C. Y. Poon, Y. T. Zhang, and P. Bonato, “Wearable medical systems for p-health,” IEEE Rev. Biomed. Eng., vol. 1, pp. 62–74, 2008, https://doi.org/10.1109/RBME.2008.2008248.10.1109/RBME.2008.2008248 ↗
3. C. Pang, C. Lee, and K. Y. Suh, “Recent advances in flexible sensors for wearable and implantable devices,” J. Appl. Polym. Sci., vol. 130, no. 3, pp. 1429–1441, 2013, https://doi.org/10.1002/APP.39461.10.1002/app.39461 ↗
4. T. Sekitani, U. Zschieschang, H. Klauk, and T. Someya, “Flexible organic transistors and circuits with extreme bending stability,” Nat. Mater., vol. 9, no. 12, pp. 1015–1022, 2010, https://doi.org/10.1038/NMAT2896.10.1038/nmat2896 ↗
5. X. Cui, L. Wu, C. Zhang, and Z. Li, “Implantable self-powered systems for electrical stimulation medical devices,” Adv. Sci., vol. 12, no. 4, p. 2412044, 2024. https://doi.org/10.1002/ADVS.202412044.10.1002/advs.202412044 ↗
6. E. Skrzetuska, D. Michalak, and I. Krucińska, “Design and analysis of electrodes for electrostimulation (TENS) using the technique of film printing and embroidery in textiles,” Sensors, vol. 21, no. 14, p. 4789, 2021, https://doi.org/10.3390/S21144789.10.3390/s21144789 ↗
7. S. Yao and Y. Zhu, “Nanomaterial-enabled dry electrodes for electrophysiological sensing: A review,” Jom, vol. 68, no. 4, pp. 1145–1155, 2016, https://doi.org/10.1007/s11837-016-1818-0.10.1007/s11837-016-1818-0 ↗
8. L. Cheng, J. Li, A. Guo, and J. Zhang, “Recent advances in flexible noninvasive electrodes for surface electromyography acquisition,” npj Flex. Electron., vol. 7, no. 1, 2023, https://doi.org/10.1038/s41528-023-00273-0.10.1038/s41528-023-00273-0 ↗
9. J. L. Vargas Luna, M. Krenn, J. A. Cortés Ramírez, and W. Mayr, “Dynamic impedance model of the skin-electrode interface for transcutaneous electrical stimulation,” PLoS One, vol. 10, no. 5, 2015, https://doi.org/10.1371/journal.pone.0125609.10.1371/journal.pone.0125609 ↗
10. J. C. Hsieh et al.., “A highly stable electrode with low electrode-skin impedance for wearable brain-computer interface,” Biosens. Bioelectron., vol. 218, 2022, https://doi.org/10.1016/j.bios.2022.114756.10.1016/j.bios.2022.114756 ↗
11. G. Rajbhandari, A. Nattestad, X. Liu, S. Beirne, and G. G. Wallace, “Fabrication of biomedical electrodes using printing approaches,” Biomed. Mater. Dev., vol. 3, no. 1, pp. 127–152, 2024, https://doi.org/10.1007/S44174-024-00176-2.10.1007/s44174-024-00176-2 ↗
12. X. Shi et al., “A sweat absorbing skin electrode for electrophysiology during exercise,” Adv. Funct. Mater., vol. 34, no. 23, p. 2314775, 2024. https://doi.org/10.1002/adfm.202314775.10.1002/adfm.202314775 ↗
13. S. Paul, A. Saikia, V. Majhi, and V. K. Pandey, “Physiotherapy equipment,” in Introduction to Biomedical Instrumentation and its Applications, Boca Raton, Florida, USA, CRC Press (Taylor & Francis Group), 2022, pp. 321–356.10.1016/B978-0-12-821674-3.00006-1 ↗
14. V. B. de Graaf-Peters and M. Hadders-Algra, “Ontogeny of the human central nervous system: What is happening when?” Early Hum. Dev., vol. 82, no. 4, pp. 257–266, 2006, https://doi.org/10.1016/j.earlhumdev.2005.10.013.10.1016/j.earlhumdev.2005.10.013 ↗
15. A. Ghosh, J. T. Orasugh, S. S. Ray, and D. Chattopadhyay, “Integration of 3D printing-coelectrospinning: Concept shifting in biomedical applications,” ACS Omega, vol. 8, no. 31, pp. 28002–28025, 2023, https://doi.org/10.1021/ACSOMEGA.3C03920/ASSET/IMAGES/LARGE/AO3C03920_0007.JPEG.10.1021/acsomega.3c03920 ↗
16. M. P. Paulus, “Decision-making dysfunctions in psychiatry – altered homeostatic processing?” Science, vol. 318, no. 5850, pp. 602–606, 2007, https://doi.org/10.1126/science.1142997.10.1126/science.1142997 ↗
17. A. Ali, J. Militky, B. Tomkova, and J. Wiener, “Design of electrically conductive highly stretchable hygienic electrodes for electrotherapy,” Fibres Text., vol. 32, no. 1, pp. 63–67, 2025, https://doi.org/10.15240/tul/008/2025-1-012.10.15240/tul/008/2025-1-012 ↗
18. D. B. Popović, “Advances in functional electrical stimulation (FES),” J. Electromyogr. Kinesiol., vol. 24, no. 6, pp. 795–802, 2014, https://doi.org/10.1016/j.jelekin.2014.09.008.10.1016/j.jelekin.2014.09.008 ↗
19. G. J. Corley, P. P. Breen, S. I. Bîrlea, J. M. Serrador, P. A. Grace, and G. Ólaighin, “Hemodynamic effects of habituation to a week-long program of neuromuscular electrical stimulation,” Med. Eng. Phys., vol. 34, no. 4, pp. 459–465, 2012, https://doi.org/10.1016/j.medengphy.2011.08.005.10.1016/j.medengphy.2011.08.005 ↗
20. M. J. Hsu, S. H. Wei, and Y. J. Chang, “Effect of neuromuscular electrical muscle stimulation on energy expenditure in healthy adults,” Sensors, vol. 11, no. 2, pp. 1932–1942, 2011, https://doi.org/10.3390/s110201932.10.3390/s110201932 ↗
21. S. E. John et al.., “An automated system for rapid evaluation of high-density electrode arrays in neural prostheses,” J. Neural Eng., vol. 8, no. 3, 2011, https://doi.org/10.1088/1741-2560/8/3/036011.10.1088/1741-2560/8/3/036011 ↗
22. J. Knibbe, A. Alsmith, and K. Hornbæk, “Experiencing electrical muscle stimulation,” Proc. ACM Interact. Mob. Wearable Ubiquitous Technol., vol. 2, no. 3, pp. 1–14, 2018, https://doi.org/10.1145/3264928.10.1145/3264928 ↗
23. A. N. Dalrymple et al.., “Electrochemical and biological performance of chronically stimulated conductive hydrogel electrodes,” J. Neural Eng., vol. 17, no. 2, p. 026018, 2020, https://doi.org/10.1088/1741-2552/ab7cfc.10.1088/1741-2552/ab7cfc ↗
24. M. R. Neuman, “Chapter 5: Biopotential electrodes,” in Medical Instrumentation: Application and Design, 4th ed., J. G. Webster, Ed., Hoboken, NJ, USA, John Wiley & Sons, Inc., 2010, pp. 189–240.
25. E. Nemati, M. J. Deen, and T. Mondal, “A wireless wearable ECG sensor for long-term applications,” IEEE Commun. Mag., vol. 50, no. 1, pp. 36–43, 2012, https://doi.org/10.1109/MCOM.2012.6122530.10.1109/MCOM.2012.6122530 ↗
26. L. Euler, L. Guo, and N.-K. Persson, “A review of textile-based electrodes developed for electrostimulation,” Text. Res. J., vol. 92, nos. 7–8, pp. 1300–1320, 2022, https://doi.org/10.1177/00405175211051949.10.1177/00405175211051949 ↗
27. M. Glanc-Gostkiewicz, M. Sophocleous, J. K. Atkinson, and E. Garcia-Breijo, “Performance of miniaturised thick-film solid state pH sensors,” Sens. Actuators, A Phys., vol. 202, pp. 2–7, 2013, https://doi.org/10.1016/j.sna.2013.04.012.10.1016/j.sna.2013.04.012 ↗
28. L. Yang et al.., “Insight into the contact impedance between the electrode and the skin surface for electrophysical recordings,” ACS Omega, vol. 7, no. 16, pp. 13906–13912, 2022, https://doi.org/10.1021/ACSOMEGA.2C00282.10.1021/acsomega.2c00282 ↗
29. E. McAdams, “Biomedical electrodes for biopotential monitoring and electrostimulation,” pp. 31–124, 2011, https://doi.org/10.1007/978-1-4419-6597-4_3.10.1007/978-1-4419-6597-4_3 ↗
30. B. Moineau, C. Marquez-Chin, M. Alizadeh-Meghrazi, and M. R. Popovic, “Garments for functional electrical stimulation: Design and proofs of concept,” J. Rehabil. Assist. Technol. Eng., vol. 6, p. 205566831985434, 2019, https://doi.org/10.1177/2055668319854340.10.1177/2055668319854340 ↗
31. T. Inoh et al.., “Nanofiber web textile dry electrodes for long-term biopotential recording,” IEEE Trans. Biomed. Circuits Syst., vol. 7, no. 2, pp. 204–11, 2013, https://doi.org/10.1109/tbcas.2012.2201154.10.1109/TBCAS.2012.2201154 ↗
32. A. Curteza, V. Cretu, L. Macovei, and M. Poboroniuc, “The manufacturing of textile products with incorporated electrodes,” Autex Res. J., vol. 16, no. 1, pp. 13–18, 2016, https://doi.org/10.1515/aut-2015-0049.10.1515/aut-2015-0049 ↗
33. G. G. Berk, “Design of a wearable pain management system with embroidered TENS electrodes,” Int. J. Cloth. Sci. Tech., vol. 30, no. 1, pp. 38–48, 2018, https://doi.org/10.1108/ijcst-04-2017-0047.10.1108/IJCST-04-2017-0047 ↗
34. B. Taji, S. Shirmohammadi, V. Groza, and I. Batkin, “Impact of skin-electrode interface on electrocardiogram measurements using conductive textile electrodes,” IEEE Trans. Instrum. Meas., vol. 63, no. 6, pp. 1412–1422, 2014, https://doi.org/10.1109/TIM.2013.2289072.10.1109/TIM.2013.2289072 ↗
35. M. R. Rizk, M. G. Abd El-Moghny, A. Mazhar, M. S. El-Deab, and B. E. El-Anadouli, “Dual-functioning porous catalysts: Robust electro-oxidation of small organic molecules and water electrolysis using bimetallic Ni/Cu foams,” Sustain. Energy Fuels, vol. 5, no. 4, pp. 986–994, 2021, https://doi.org/10.1039/D0SE01835J.10.1039/D0SE01835J ↗
36. Z.-Y. Wu et al.., “Rubber-based carbon electrode materials derived from dumped tires for efficient sodium-ion storage,” Dalton Trans., vol. 47, no. 14, pp. 4885–4892, 2018, https://doi.org/10.1039/C8DT00504D.10.1039/C8DT00504D ↗
37. S. Kaufmann, G. Ardelt, and M. Ryschka, “Measurements of electrode skin impedances using carbon rubber electrodes – first results,” J. Phys. Conf. Ser., vol. 434, no. 1, 2013, https://doi.org/10.1088/1742-6596/434/1/012020.10.1088/1742-6596/434/1/012020 ↗
38. T. Greig, R. Torah, and K. Yang, “Electrical stimulation for wound healing: Opportunities for E-textiles,” IEEE Rev. Biomed. Eng., vol. 17, pp. 264–279, 2024, https://doi.org/10.1109/RBME.2022.3210598.10.1109/RBME.2022.3210598 ↗
39. V. L. D. S. N. Button, “Electrodes for biopotential recording and tissue stimulation,” in Principles of Measurement and Transduction of Biomedical Variables, Oxford, UK, Academic Press (an imprint of Elsevier), 2015, pp. 25–76.10.1016/B978-0-12-800774-7.00002-7 ↗
40. E. Santos, R. Nazmutdinov, and W. Schmickler, “Electron transfer at different electrode materials: Metals, semiconductors, and graphene,” Curr. Opin. Electrochem., vol. 19, pp. 106–112, 2020, https://doi.org/10.1016/J.COELEC.2019.11.003.10.1016/j.coelec.2019.11.003 ↗
41. K. Goyal, D. A. Borkholder, and S. W. Day, “A biomimetic skin phantom for characterizing wearable electrodes in the low-frequency regime,” Sens. Actuators, A Phys., vol. 340, p. 113513, 2022, https://doi.org/10.1016/J.SNA.2022.113513.10.1016/j.sna.2022.113513 ↗
42. F. B. Madsen, A. E. Daugaard, S. Hvilsted, and A. L. Skov, “The current state of silicone-based dielectric elastomer transducers,” Macromol. Rapid Commun., vol. 37, no. 5, pp. 378–413, 2016, https://doi.org/10.1002/marc.201500576.10.1002/marc.201500576 ↗
43. Y.-H. Yu, S.-H. Chen, C.-L. Chang, C.-T. Lin, W. Hairston, and R. Mrozek, “New flexible silicone-based EEG dry sensor material compositions exhibiting improvements in lifespan, conductivity, and reliability,” Sensors, vol. 16, no. 11, p. 1826, 2016, https://doi.org/10.3390/s16111826.10.3390/s16111826 ↗
44. S. Mulier et al.., “Electrodes and multiple electrode systems for radiofrequency ablation: A proposal for updated terminology,” Eur. Radiol., vol. 15, no. 4, pp. 798–808, 2005, https://doi.org/10.1007/s00330-004-2584-x.10.1007/s00330-004-2584-x ↗
45. Ø. G. Martinsen and A. Heiskanen, “Electrodes,” in Bioimpedance and Bioelectricity Basics, Oxford, UK, Academic Press,Elsevier, 2023, pp. 175–248.10.1016/B978-0-12-819107-1.00005-4 ↗
46. S. Oribe et al.., “Hydrogel-based organic subdural electrode with high conformability to brain surface,” Sci. Rep., vol. 9, no. 1, 2019, https://doi.org/10.1038/s41598-019-49772-z.10.1038/s41598-019-49772-z ↗
47. R. Romero-Méndez, F. G. Pérez-Gutiérrez, F. Oviedo-Tolentino, and E. Berjano, “Analytical solution for electrical problem forced by a finite‐length needle electrode: Implications in electrostimulation,” Math. Probl. Eng., vol. 2019, no. 1, 2019, https://doi.org/10.1155/2019/2404818.10.1155/2019/2404818 ↗
48. G. Cooper, A. T. Barker, B. W. Heller, T. Good, L. P. J. Kenney, and D. Howard, “The use of hydrogel as an electrode–skin interface for electrode array FES applications,” Med. Eng. Phys., vol. 33, no. 8, pp. 967–972, 2011, https://doi.org/10.1016/j.medengphy.2011.03.008.10.1016/j.medengphy.2011.03.008 ↗
49. S. Pan et al.., “Mechanically interlocked hydrogel–elastomer hybrids for on-skin electronics,” Adv. Funct. Mater., vol. 30, no. 29, 2020, https://doi.org/10.1002/adfm.201909540.10.1002/adfm.201909540 ↗
50. G. Li et al.., “Towards emerging EEG applications: A novel printable flexible Ag/AgCl dry electrode array for robust recording of EEG signals at forehead sites,” J. Neural Eng., vol. 17, no. 2, 2020, https://doi.org/10.1088/1741-2552/ab71ea.10.1088/1741-2552/ab71ea ↗
51. B. A. Reyes et al.., “Novel electrodes for underwater ECG monitoring,” IEEE Trans. Biomed. Eng., vol. 61, no. 6, pp. 1863–1876, 2014, https://doi.org/10.1109/TBME.2014.2309293.10.1109/TBME.2014.2309293 ↗
52. R. Castrillón, J. J. Pérez, and H. Andrade-Caicedo, “Electrical performance of PEDOT: PSS-based textile electrodes for wearable ECG monitoring: A comparative study,” Biomed. Eng. Online, vol. 17, no. 1, 2018, https://doi.org/10.1186/s12938-018-0469-5.10.1186/s12938-018-0469-5 ↗
53. A. Ali et al.., “Silver-plated stretchable elastomeric electrodes for electrotherapy applications,” J. Ind. Text., vol. 54, 2024. https://doi.org/10.1177/15280837241287561.10.1177/15280837241287561 ↗
54. R. Yin et al.., “Soft transparent graphene contact lens electrodes for conformal full-cornea recording of electroretinogram,” Nat. Commun., vol. 9, no. 1, 2018, https://doi.org/10.1038/s41467-018-04781-w.10.1038/s41467-018-04781-w ↗
55. B. Huang, Q. Wang, W. Li, and D. Kong, “Stretchable and body conformable electronics for emerging wearable therapies,” Interdiscip. Med., vol. 3, no. 1, p. e20240064, 2024. https://doi.org/10.1002/INMD.20240064.10.1002/INMD.20240064 ↗
56. C. M. Vidhya, Y. Maithani, and J. P. Singh, “Recent advances and challenges in textile electrodes for wearable biopotential signal monitoring: A comprehensive review,” Biosensors, vol. 13, no. 7, p. 679, 2023, https://doi.org/10.3390/BIOS13070679.10.3390/bios13070679 ↗
57. B. J. Polk, A. Stelzenmuller, G. Mijares, W. MacCrehan, and M. Gaitan, “Ag/AgCl microelectrodes with improved stability for microfluidics,” Sens. Actuators B Chem., vol. 114, no. 1, pp. 239–247, 2006, https://doi.org/10.1016/j.snb.2005.03.121.10.1016/j.snb.2005.03.121 ↗
58. J. Zhou et al.., “Fabrication of a microfluidic Ag/AgCl reference electrode and its application for portable and disposable electrochemical microchips,” Electrophoresis, vol. 31, no. 18, pp. 3083–3089, 2010, https://doi.org/10.1002/elps.201000113.10.1002/elps.201000113 ↗
59. Z. Saadatnia, S. Ghaffarimosanenzadeh, M. Marquez Chin, H. E. Naguib, and M. R. Popovic, “Flexible, air dryable, and fiber modified aerogel-based wet electrode for electrophysiological monitoring,” IEEE Trans. Biomed. Eng., vol. 68, no. 6, pp. 1820–1827, 2021, https://doi.org/10.1109/TBME.2020.302261.10.1109/TBME.2020.3022615 ↗
60. L. F. Arenas, C. Ponce de León, and F. C. Walsh, “Three-dimensional porous metal electrodes: Fabrication, characterisation and use,” Curr. Opin. Electrochem., vol. 16, pp. 1–9, 2019, https://doi.org/10.1016/J.COELEC.2019.02.002.10.1016/j.coelec.2019.02.002 ↗
61. J. Deng, J. Li, S. Song, Y. Zhou, and L. Li, “Electrolyte-dependent supercapacitor performance on nitrogen-doped porous bio-carbon from gelatin,” Nanomaterials, vol. 10, no. 2, p. 353, 2020, https://doi.org/10.3390/nano10020353.10.3390/nano10020353 ↗
62. S. N. Iwasa et al.., “Novel electrode designs for neurostimulation in regenerative medicine: Activation of stem cells,” Bioelectricity, vol. 2, no. 4, pp. 348–361, 2020, https://doi.org/10.1089/bioe.2020.0034.10.1089/bioe.2020.0034 ↗
63. Y. Ding et al.., “Porous conductive textiles for wearable electronics,” Chem. Rev., vol. 124, no. 4, pp. 1535–1648, 2024, https://doi.org/10.1021/ACS.CHEMREV.3C00507/ASSET/IMAGES/MEDIUM/CR3C00507_0078.GIF.10.1021/acs.chemrev.3c00507 ↗
64. A. Stein, B. Fan, and M. Kim, “Colloidal crystal templating of porous materials,” in Encyclopedia of Nanomaterials, 2023, pp. V3-149–V3-164.10.1016/B978-0-12-822425-0.00012-9 ↗
65. M. Marquez-Chin, Z. Saadatnia, H. E. Naguib, and M. R. Popovic, “Development of an aerogel-based wet electrode for functional electrical stimulation,” IEEE Trans. Neural Syst. Rehabil. Eng., vol. 31, pp. 4085–4095, 2023, https://doi.org/10.1109/TNSRE.2023.3324400.10.1109/TNSRE.2023.3324400 ↗
66. Y. Liu et al.., “NaCl-assisted synthesis of porous carbons with ultra-high electrical conductivity for high-performance supercapacitors,” J. Power Sources, vol. 553, p. 232301, 2023, https://doi.org/10.1016/J.JPOWSOUR.2022.232301.10.1016/j.jpowsour.2022.232301 ↗
67. F. E. Ahmed, B. S. Lalia, and R. Hashaikeh, “A review on electrospinning for membrane fabrication: Challenges and applications,” Desalination, vol. 356, pp. 15–30, 2015, https://doi.org/10.1016/J.DESAL.2014.09.033.10.1016/j.desal.2014.09.033 ↗
68. J. T. Davis et al.., “3D printed optimized electrodes for electrochemical flow reactors,” Sci. Rep., vol. 14, no. 1, p. 22662, 2024, https://doi.org/10.1038/S41598-024-71765-W.10.1038/s41598-024-71765-w ↗
69. E. Lahtinen et al.., “Preparation of highly porous carbonous electrodes by selective laser sintering,” ACS Appl. Energy Mater., vol. 2, no. 2, pp. 1314–1318, 2019, https://doi.org/10.1021/ACSAEM.8B01881/ASSET/IMAGES/LARGE/AE-2018-01881G_0004.JPEG.10.1021/acsaem.8b01881 ↗
70. R. Elango, A. Demortière, V. De Andrade, M. Morcrette, and V. Seznec, “Thick binder-free electrodes for Li–Ion battery fabricated using templating approach and spark plasma sintering reveals high areal capacity,” Adv. Energy Mater., vol. 8, no. 15, p. 1703031, 2018, https://doi.org/10.1002/AENM.201703031.10.1002/aenm.201703031 ↗
71. R. Abdulhussain, A. Adebisi, B. R. Conway, and K. Asare-Addo, “Electrospun nanofibers: Exploring process parameters, polymer selection, and recent applications in pharmaceuticals and drug delivery,” J. Drug Deliv. Sci. Technol., vol. 90, p. 105156, 2023, https://doi.org/10.1016/J.JDDST.2023.105156.10.1016/j.jddst.2023.105156 ↗
72. T. Boretius, T. Jurzinsky, C. Koehler, S. Kerzenmacher, H. Hillebrecht, and T. Stieglitz, “High-porous platinum electrodes for functional electrical stimulation,” Annu. Int. Conf. IEEE Eng. Med. Biol. Soc., vol. 2011, pp. 5404–5407, 2011, https://doi.org/10.1109/IEMBS.2011.6091336.10.1109/IEMBS.2011.6091336 ↗
73. Y. Çeli̇k and A. Kurt, “Three dimensional porous expanded graphite/silver nanoparticles nanocomposite platform as a SERS substrate,” Appl. Surf. Sci., vol. 568, p. 150946, 2021, https://doi.org/10.1016/J.APSUSC.2021.150946.10.1016/j.apsusc.2021.150946 ↗
74. A. Kloke, F. von Stetten, R. Zengerle, and S. Kerzenmacher, “Strategies for the fabrication of porous platinum electrodes,” Adv. Mater., vol. 23, no. 43, pp. 4976–5008, 2011, https://doi.org/10.1002/adma.201102182.10.1002/adma.201102182 ↗
75. L. F. Arenas, C. Ponce de León, and F. C. Walsh, “3D-printed porous electrodes for advanced electrochemical flow reactors: A Ni/stainless steel electrode and its mass transport characteristics,” Electrochem. Commun., vol. 77, pp. 133–137, 2017, https://doi.org/10.1016/j.elecom.2017.03.009.10.1016/j.elecom.2017.03.009 ↗
76. Q. Li, et al., “Review of printed electrodes for flexible devices,” Front. Mater., vol. 5, p. 433510, 2019. https://doi.org/10.3389/fmats.2018.00077.10.3389/fmats.2018.00077 ↗
77. S. Park, Y. J. Song, H. Boo, and T. D. Chung, “Nanoporous Pt microelectrode for neural stimulation and recording: In vitro characterization,” J. Phys. Chem. C, vol. 114, no. 19, pp. 8721–8726, 2010, https://doi.org/10.1021/JP911256H/ASSET/IMAGES/MEDIUM/JP-2009-11256H_0006.GIF.10.1021/jp911256h ↗
78. M. Frei et al.., “Pulsed electrodeposition of highly porous Pt alloys for use in methanol, formic acid, and glucose fuel cells,” ChemElectroChem, vol. 5, no. 7, pp. 1013–1023, 2018, https://doi.org/10.1002/celc.201800035.10.1002/celc.201800035 ↗
79. A. Kasry, M. A. Kuroda, G. J. Martyna, G. S. Tulevski, and A. A. Bol, “Chemical doping of large-area stacked graphene films for use as transparent, conducting electrodes,” ACS Nano, vol. 4, no. 7, pp. 3839–3844, 2010, https://doi.org/10.1021/nn100508g.10.1021/nn100508g ↗
80. Y. Lu, H. Lyu, A. G. Richardson, T. H. Lucas, and D. Kuzum, “Flexible neural electrode array based-on porous graphene for cortical microstimulation and sensing,” Sci. Rep., vol. 6, no. 1, pp. 1–9, 2016, https://doi.org/10.1038/srep33526.10.1038/srep33526 ↗
81. N. Kapadia, B. Moineau, and M. R. Popovic, “Functional electrical stimulation therapy for retraining reaching and grasping after spinal cord injury and stroke,” Front. Neurosci., vol. 14, 2020, https://doi.org/10.3389/fnins.2020.00718.10.3389/fnins.2020.00718 ↗
82. H. Zhou et al.., “Stimulating the comfort of textile electrodes in wearable neuromuscular electrical stimulation,” Sensors (Basel), vol. 15, no. 7, pp. 17241–17257, 2015, https://doi.org/10.3390/S150717241.10.3390/s150717241 ↗
83. M. T. Noman et al.., “Aerogels for biomedical, energy and sensing applications,” Gels, vol. 7, no. 4, p. 264, 2021, https://doi.org/10.3390/gels7040264.10.3390/gels7040264 ↗
84. H. Maleki, L. Durães, and A. Portugal, “An overview on silica aerogels synthesis and different mechanical reinforcing strategies,” J. Non. Cryst. Solids, vol. 385, pp. 55–74, 2014, https://doi.org/10.1016/j.jnoncrysol.2013.10.017.10.1016/j.jnoncrysol.2013.10.017 ↗
85. M. T. Noman, N. Amor, and M. Petru, “Synthesis and applications of ZnO nanostructures (ZONSs): A review,” Crit. Rev. Solid State Mater. Sci., vol. 47, no. 2, pp. 99–141, 2022, https://doi.org/10.1080/10408436.2021.1886041.10.1080/10408436.2021.1886041 ↗
86. T. Alizadeh and L. Hamedsoltani, “Managing of gas sensing characteristic of a reduced graphene oxide based gas sensor by the change in synthesis condition: A new approach for electronic nose design,” Mater. Chem. Phys., vol. 183, pp. 181–190, 2016, https://doi.org/10.1016/j.matchemphys.2016.08.017.10.1016/j.matchemphys.2016.08.017 ↗
87. U. Thubsuang, D. Sukanan, S. Sahasithiwat, S. Wongkasemjit, and T. Chaisuwan, “Highly sensitive room temperature organic vapor sensor based on polybenzoxazine-derived carbon aerogel thin film composite,” Mater. Sci. Eng. B, vol. 200, pp. 67–77, 2015, https://doi.org/10.1016/j.mseb.2015.06.010.10.1016/j.mseb.2015.06.010 ↗
88. J. Wu et al.., “3D superhydrophobic reduced graphene oxide for activated NO2 sensing with enhanced immunity to humidity,” J. Mater. Chem. A, vol. 6, no. 2, pp. 478–488, 2018, https://doi.org/10.1039/C7TA08775F.10.1039/C7TA08775F ↗
89. F. Yang et al.., “Three-dimensional TiO2/SiO2 composite aerogel films via atomic layer deposition with enhanced H2S gas sensing performance,” Ceram. Int., vol. 44, no. 1, pp. 1078–1085, 2018, https://doi.org/10.1016/j.ceramint.2017.10.052.10.1016/j.ceramint.2017.10.052 ↗
90. X. Liu, J. Sun, and X. Zhang, “Novel 3D graphene aerogel–ZnO composites as efficient detection for NO2 at room temperature,” Sens. Actuators B Chem., vol. 211, pp. 220–226, 2015, https://doi.org/10.1016/j.snb.2015.01.083.10.1016/j.snb.2015.01.083 ↗
91. R. Wang, G. Li, Y. Dong, Y. Chi, and G. Chen, “Carbon quantum dot-functionalized aerogels for NO2 gas sensing,” Anal. Chem., vol. 85, no. 17, pp. 8065–8069, 2013, https://doi.org/10.1021/ac401880h.10.1021/ac401880h ↗
92. C.-T. Wang and C.-L. Wu, “Electrical sensing properties of silica aerogel thin films to humidity,” Thin Solid Films, vol. 496, no. 2, pp. 658–664, 2006, https://doi.org/10.1016/j.tsf.2005.09.001.10.1016/j.tsf.2005.09.001 ↗
93. M. T. Noman and M. Petru, “Effect of sonication and nano TiO2 on thermophysiological comfort properties of woven fabrics,” ACS Omega, vol. 5, no. 20, pp. 11481–11490, 2020, https://doi.org/10.1021/acsomega.0c00572.10.1021/acsomega.0c00572 ↗
94. H. Lv, J. Chen, W. Zhou, X. Shen, and C. Zhang, “Mechanism analyses and optimization strategies for performance improvement in low-temperature water electrolysis systems via the perspective of mass transfer: A review,” Renew. Sustain. Energy Rev., vol. 183, p. 113394, 2023, https://doi.org/10.1016/j.rser.2023.113394.10.1016/j.rser.2023.113394 ↗
95. S. Rashidi, J. A. Esfahani, and N. Karimi, “Porous materials in building energy technologies – a review of the applications, modelling and experiments,” Renew. Sustain. Energy Rev., vol. 91, pp. 229–247, 2018, https://doi.org/10.1016/j.rser.2018.03.092.10.1016/j.rser.2018.03.092 ↗
96. M. Azeem, M. Shahid, I. Masin, and M. Petru, “Design and development of textile-based wearable sensors for real-time biomedical monitoring; a review,” J. Text. Inst., vol. 116, no. 1, pp. 80–95, 2025, https://doi.org/10.1080/00405000.2024.2318500.10.1080/00405000.2024.2318500 ↗
97. C. Güneşoğlu, S. Güneşoğlu, S. Wei, and Z. Guo, “The enhanced electrical conductivity of cotton fabrics via polymeric nanocomposites,” Fibers Polym., vol. 17, no. 3, pp. 402–407, 2016, https://doi.org/10.1007/S12221-016-5751-1/METRICS.10.1007/s12221-016-5751-1 ↗
98. C. Y. Hui, C. W. Kan, C. L. Mak, and K. H. Chau, “Flexible energy storage system – an introductory review of textile-based flexible supercapacitors,” Processes, vol. 7, no. 12, p. 922, 2019, https://doi.org/10.3390/PR7120922.10.3390/pr7120922 ↗
99. M. A. Shahid et al.., “Advances in conductive polymer-based flexible electronics for multifunctional applications,” J. Compos. Sci., vol. 9, no. 1, p. 42, 2025, https://doi.org/10.3390/JCS9010042.10.3390/jcs9010042 ↗
100. P. A. Lopes et al.., “Soft bioelectronic stickers: Selection and evaluation of skin-interfacing electrodes,” Adv. Healthc. Mater., vol. 8, no. 15, 2019, https://doi.org/10.1002/adhm.201900234.10.1002/adhm.201900234 ↗