journal article·2022-04Open access

Surface engineering and the application of laser-based processes to stents - A review of the latest development

J. Dong, M. Pacella, Y. Liu, L. Zhao

Abstract

Late in-stent thrombus and restenosis still represent two major challenges in stents’ design. Surface treatment of stent is attracting attention due to the increasing importance of stenting intervention for coronary artery diseases. Several surface engineering techniques have been utilised to improve the biological response in vivo on a wide range of biomedical devices. As a tailorable, precise, and ultra-fast process, laser surface engineering offers the potential to treat stent materials and fabricate various 3D textures, including grooves, pillars, nanowires, porous and freeform structures, while also modifying surface chemistry through nitridation, oxidation and coatings. Laser-based processes can reduce the biodegradable materials' degradation rate, offering many advantages to improve stents’ performance, such as increased endothelialisation rate, prohibition of SMC proliferation, reduced platelet adhesion and controlled corrosion and degradation. Nowadays, adequate research has been conducted on laser surface texturing and surface chemistry modification. Laser texturing on commercial stents has been also investigated and a promotion of performance of laser-textured stents has been proved. In this critical review, the influence of surface texture and surface chemistry on stents performance is firstly reviewed to understand the surface characteristics of stents required to facilitate cellular response. This is followed by the explicit illustration of laser surface engineering of stents and/or related materials. Laser induced periodic surface structure (LIPSS) on stent materials is then explored, and finally the application of laser surface modification techniques on latest generation of stent devices is highlighted to provide future trends and research direction on laser surface engineering of stents.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Tribology and Lubrication Engineering · Laser Material Processing Techniques · High Entropy Alloys Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (100+)

Show source-provided references
1. A study on the effect of dual blasting with TiO2 on titanium implant surfaces on functional attachment in bone10.1002/jbm.a.10580 ↗
2. Evaluation of topographical and chemical modified TiAl6V4 implant surfaces in a weight-bearing intramedullary femur model in rabbit10.1002/jbm.b.34463 ↗
3. Relationship between surface properties (roughness, wettability and morphology) of titanium and dental implant removal torque10.1016/j.jmbbm.2007.12.002 ↗
4. Creation and description of sand blasted stamp created micro roughness on polyetheretherketone with subsequent physical vapor deposition coating for promotion of osseointegration10.1002/mawe.201700181 ↗
5. Effects of sandblasting and silica-coating procedures on pure titanium10.1016/0300-5712(94)90067-1 ↗
6. The meaning of aluminium exposure on human health and aluminium-related diseases10.1515/bmc-2012-0045 ↗
7. Effect of sulfuric acid etching of polyetheretherketone on the shear bond strength to resin cements
8. Alkali etching of a poly(lactide) fiber10.1021/am900227f ↗
9. Antibacterial activities and biocompatibilities of Ti-Ag alloys prepared by spark plasma sintering and acid etching10.1016/j.msec.2018.06.024 ↗
10. DNA damage, apoptosis and cell cycle changes induced by fluoride in rat oral mucosal cells and hepatocytes10.3748/wjg.v12.i7.1144 ↗
11. Surface treatments of zirconia to enhance bonding durability10.2341/14-144-L ↗
12. Plasma assisted surface treatments of biomaterials10.1016/j.bpc.2017.07.003 ↗
13. Laser surface treatment
14. Plasma-induced nanopillars on bare metal coronary stent surface for enhanced endothelialization10.1016/j.actbio.2010.07.007 ↗
15. Surface functionalization of biomaterials by plasma and ion beam10.1016/j.surfcoat.2017.08.011 ↗
16. Plasma polymerised polyoxazoline thin films for biomedical applications10.1039/C5CC00260E ↗
17. Loya · 2010
18. Plasma-surface modification of biomaterials10.1016/S0927-796X(02)00004-9 ↗
19. Laser interference lithography
20. Biomimetic surface structuring using cylindrical vector femtosecond laser beams10.1038/srep45114 ↗
21. Fabrication of hydrophobic structures on stent by direct three-beam laser interference lithography10.1016/j.ijleo.2016.02.075 ↗
22. Pharmacological approaches to the prevention of restenosis after coronary angioplasty10.2165/00002512-199813040-00005 ↗
23. Félétou · 2011
24. Medical therapies for the prevention of restenosis after percutaneous coronary interventions10.1016/S0146-2806(98)80002-9 ↗
25. Usefulness of a cobalt chromium coronary stent alloy10.1016/S0002-9149(03)00669-6 ↗
26. “TCT-226: CARE II 8 Month follow-up results with the CardioMind® 0.014” Sparrow® sirolimus-eluting nitinol stent system10.1016/j.jacc.2010.08.251 ↗
27. Randomized comparison of a titanium-nitride-oxide-coated stent with a stainless steel stent for coronary revascularization - the TiNOX trial10.1161/CIRCULATIONAHA.104.486647 ↗
28. Bio-resorbable polymer stents: a review of material progress and prospects10.1016/j.progpolymsci.2018.05.002 ↗
29. A promising biodegradable magnesium alloy suitable for clinical vascular stent application10.1038/srep46343 ↗
30. Zinc-based alloys for degradable vascular stent applications10.1016/j.actbio.2018.03.005 ↗
31. In vitro analyses of diamond-like carbon coated stents: reduction of metal ion release, platelet activation, and thrombogenicity10.1016/S0049-3848(00)00295-4 ↗
32. “Comparison of a silicon carbide-coated stent versus a noncoated stent in human beings: the Tenax versus Nir Stent Study's long-term outcome10.1067/mhj.2003.90 ↗
33. Mussel-inspired elastic interpenetrated network hydrogel as an alternative for anti-thrombotic stent coating membrane10.1016/j.cej.2018.04.098 ↗
34. Improved adhesion at titanium surfaces via laser-induced surface oxidation and roughening10.1016/j.msea.2012.08.101 ↗
35. Self-organized micro/nano structures in metal surfaces by ultrafast laser irradiation10.1016/j.optlaseng.2010.04.010 ↗
36. Femtosecond laser direct writing of porous network microstructures for fabricating super-slippery surfaces with excellent liquid repellence and anti-cell proliferation
37. Mechanism of critical catalyst size effect on MgO nanowire growth by pulsed laser deposition10.1063/1.2937194 ↗
38. Femtosecond laser induced nanostructure formation: self-organization control parameters10.1007/s00339-008-4671-3 ↗
39. Influence of membrane surface properties on the growth of neuronal cells isolated from hippocampus10.1016/j.memsci.2008.07.022 ↗
40. Decreased platelet adhesion and enhanced endothelial cell functions on nano and submicron-rough titanium stents10.1089/ten.tea.2011.0268 ↗
41. Enhancement of the growth of human endothelial cells by surface roughness at nanometer scale10.1016/S0142-9612(03)00361-2 ↗
42. Increased endothelial and vascular smooth muscle cell adhesion on nanostructured titanium and CoCrMo10.2147/nano.2006.1.1.41 ↗
43. The role of nanometer and sub-micron surface features on vascular and bone cell adhesion on titanium10.1016/j.biomaterials.2007.11.009 ↗
44. In vitro study of human vascular endothelial cell function on materials with various surface roughness10.1002/jbm.a.30143 ↗
45. Nano-micrometer surface roughness gradients reveal topographical influences on differentiating responses of vascular cells on biodegradable magnesium
46. Different sensitivity of human endothelial cells, smooth muscle cells and fibroblasts to topography in the nano-micro range10.1016/j.actbio.2009.04.003 ↗
47. The effect of surface roughness on activation of the coagulation system and platelet adhesion in rotary blood pumps10.1111/j.1525-1594.2007.00391.x ↗
48. Effect of extreme wettability on platelet adhesion on metallic implants: from superhydrophilicity to superhydrophobicity10.1021/acsami.6b03644 ↗
49. Comparative endothelial cell response on topographically patterned titanium and silicon substrates with micrometer to sub-micrometer feature sizes10.1371/journal.pone.0111465 ↗
50. Improved endothelial cell adhesion and proliferation on patterned titanium surfaces with rationally designed, micrometer to nanometer features10.1016/j.actbio.2007.07.008 ↗
51. Effects of titanium-coated micromachined grooved substrata on orienting layers of osteoblast-like cells and collagen fibers in culture10.1002/jbm.a.30058 ↗
52. Cell orientation by a microgrooved substrate can be predicted by automatic control theory10.1529/biophysj.105.067967 ↗
53. Phenotypic modulation of primary vascular smooth muscle cells by short-term culture on micropatterned substrate10.1371/journal.pone.0088089 ↗
54. Effects of microtopographic patterns on platelet adhesion and activation on titanium oxide surfaces10.1002/jbm.a.34361 ↗
55. Platelet adhesion studies on nanostructured poly(lactic-co-glycolic-acid)- carbon nanotube composite
56. New explanations for old observations: marginal band coiling during platelet activation10.1111/jth.12819 ↗
57. Response of human blood platelets on nanoscale groove patterns: implications for platelet storage10.1021/acsanm.0c01326 ↗
58. Plasma-induced nanopillars on bare metal coronary stent surface for enhanced endothelialization10.1016/j.actbio.2010.07.007 ↗
59. A biodegradable and biocompatible regular nanopattern for large-scale selective cell growth10.1002/smll.201000193 ↗
60. Nitinol-based nanotubular coatings for the modulation of human vascular cell function10.1021/nl501523v ↗
61. Sub-micron texturing for reducing platelet adhesion to polyurethane biomaterials10.1002/jbm.a.30554 ↗
62. RF magnetron sputtering deposition of TiO2 thin films in a small continuous oxygen flow rate10.3390/coatings9070442 ↗
63. Human aortic endothelial cell morphology influenced by topography of porous silicon substrates10.1177/0885328215588414 ↗
64. “Membrane pore spacing can modulate endothelial cell–substrate and cell–cell interactions10.1021/acsbiomaterials.7b00055 ↗
65. Inhibition of neointima formation by a novel drug-eluting stent system that allows for dose-adjustable, multiple, and on-site stent coating10.1161/01.ATV.0000157579.52566.ee ↗
66. Influence of nanoporesize on platelet adhesion and activation10.1007/s10856-008-3449-7 ↗
67. Nanoporous aluminum oxide affects neutrophil behaviour10.1002/jemt.20040 ↗
68. Micro- and nanostructured Al 2O 3 surfaces for controlled vascular endothelial and smooth muscle cell adhesion and proliferation10.1016/j.msec.2012.02.032 ↗
69. Successful reduction of neointimal hyperplasia on stainless steel coronary stents by titania nanotexturing10.1021/acsomega.0c02045 ↗
70. Stable titania nanostructures on stainless steel coronary stent surface for enhanced corrosion resistance and endothelialization10.1002/adhm.201601353 ↗
71. Investigation of surface endothelialization on biomedical nitinol (NiTi) alloy: effects of surface micropatterning combined with plasma nanocoatings10.1016/j.actbio.2009.05.021 ↗
72. Comparison of diamond-like carbon-coated stents versus uncoated stainless steel stents in coronary artery disease10.1016/j.amjcard.2003.10.048 ↗
73. Oxygen-rich coating promotes binding of proteins and endothelialization of polyethylene terephthalate polymers10.1002/jbm.a.34911 ↗
74. Al2O3 micro- and nanostructures affect vascular cell response10.1039/C5RA21775J ↗
75. Chapter 1 introduction
76. Hierarchical periodic micro/nano-structures on nitinol and their influence on oriented endothelialization and anti-thrombosis10.1016/j.msec.2015.07.028 ↗
77. Tissue engineering of blood vessels: characterization of smooth-muscle cells for culturing on collagen-and-elastin-based scaffolds10.1042/BA20030105 ↗
78. Synthesis and blood compatibility of rutile-type titanium oxide coated LTI-carbon10.1007/BF02882740 ↗
79. Stent coating with titanium-nitride-oxide for reduction of neointimal hyperplasia10.1161/hc3401.093146 ↗
80. “Titanium-Nitride-Oxide–Coated versus everolimus-eluting stents in acute coronary syndrome: the randomized TIDES-ACS trial10.1016/j.jcin.2020.04.021 ↗
81. Five-year clinical outcome of titanium-nitride-oxide-coated bioactive stents versus paclitaxel-eluting stents in patients with acute myocardial infarction: long-term follow-up from the TITAX AMI trial10.1016/j.ijcard.2012.11.060 ↗
82. “Early vascular healing after titanium–nitride–oxide-coated stent versus platinum–chromium everolimus-eluting stent implantation in patients with acute coronary syndrome10.1007/s10554-016-0871-7 ↗
83. Comparison of titanium-nitride-oxidecoated stents with zotarolimus-eluting stents for coronary revascularization: a randomized controlled trial10.1016/j.jcin.2011.02.017 ↗
84. Does carbofilm coating affect in-stent intimal proliferation? A randomized trial comparing Rx multi-link penta and tecnic carbostentTM stents10.1111/j.1540-8183.2007.00281.x ↗
85. “Clinical and angiographic outcomes following elective implantation of the carbostent in patients at high risk of restenosis and target vessel failure,” Catheter10.1002/ccd.2004 ↗
86. Clinical and angiographic outcome after coronary arterial stenting with the carbostent10.1016/S0002-9149(99)00874-7 ↗
87. Pasquino · 1993 · vol. 19 · 169
88. Mechanical stability, corrosion performance and bioresponse of amorphous diamond-like carbon for medical stents and guidewires10.1016/j.diamond.2004.12.023 ↗
89. “Differences of platelet adhesion and thrombus activation on amorphous silicon carbide, magnesium alloy, stainless steel, and cobalt chromium stent surfaces,” Catheter10.1002/ccd.21834 ↗
90. “Silicon carbide coating of nitinol stents to increase antithrombogenic properties and reduce nickel release,” Cardiovasc10.1016/j.carrev.2008.03.004 ↗
91. Improvement of haemocompatibility of metallic stents by polymer coating10.1023/A:1008939400812 ↗
92. Comparison of a polymer-based paclitaxel-eluting stent with a bare metal stent in patients with complex coronary artery disease: a randomized controlled trial10.1001/jama.294.10.1215 ↗
93. Stent thrombosis late after implantation of first-generation drug-eluting stents: a cause for concern10.1161/CIRCULATIONAHA.106.666800 ↗
94. Biodegradable polymer biolimus-eluting stent (NOBORI®) for the treatment of coronary artery lesions: review of concept and clinical results
95. The Excel stent: a good DES, but can we really stop clopidogrel after 6 Months?10.1016/j.jcin.2009.01.005 ↗
96. A novel drug-eluting stent using bioabsorbable polymer technology: two-year follow-up of the CURAMI registry10.1016/j.ijcard.2007.07.074 ↗
97. Biodegradable-polymer-based, paclitaxel-eluting Infinnium stent: 9-Month clinical and angiographic follow-up results from the SIMPLE II prospective multi-centre registry study
98. Zandstra · 2016
99. “TCT-226: CARE II 8 Month follow-up results with the CardioMind® 0.014” Sparrow® sirolimus-eluting nitinol stent system10.1016/j.jacc.2010.08.251 ↗
100. Phospholipid-based multifunctional coating via layer-by-layer self-assembly for biomedical applications10.1016/j.msec.2020.111237 ↗