journal article·2020-09Open access

Characteristics of novel Ti–10Mo-xCu alloy by powder metallurgy for potential biomedical implant applications

Wei Xu, Chenjin Hou, Yuxuan Mao, Lei Yang, Maryam Tamaddon, Jianliang Zhang, Xuanhui Qu, Chaozong Liu, Bo Su, Xin Lu

Bioactive Materials· Volume 5· Issue 3

Abstract

When biomaterials are implanted in the human body, the surfaces of the implants become favorable sites for microbial adhesion and biofilm formation, causing peri-implant infection which frequently results in the failure of prosthetics and revision surgery. Ti–Mo alloy is one of the commonly used implant materials for load-bearing bone replacement, and the prevention of infection of Ti–Mo implants is therefore crucial. In this study, bacterial inhibitory copper (Cu) was added to Ti–Mo matrix to develop a novel Ti–Mo–Cu alloy with bacterial inhibitory property. The effects of Cu content on microstructure, tensile properties, cytocompatibility, and bacterial inhibitory ability of Ti–Mo–Cu alloy were systematically investigated. Results revealed that Ti–10Mo–1Cu alloy consisted of α and β phases, while there were a few Ti2Cu intermetallic compounds existed for Ti–10Mo–3Cu and Ti–10Mo–5Cu alloys, in addition to α and β phases. The tensile strength of Ti–10Mo-xCu alloy increased with Cu content while elongation decreased. Ti–10Mo–3Cu alloy exhibited an optimal tensile strength of 1098.1 MPa and elongation of 5.2%. Cytocompatibility study indicated that none of the Ti–10Mo-xCu alloys had a negative effect on MC3T3-E1 cell proliferation. Bacterial inhibitory rates against S. aureus and E. coli increased with the increase in Cu content of Ti–10Mo-xCu alloy, within the ranges of 20–60% and 15–50%, respectively. Taken together, this study suggests that Ti–10Mo–3Cu alloy with high strength, acceptable elongation, excellent cytocompatibility, and the bacterial inhibitory property is a promising candidate for biomedical implant applications.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty · Advanced materials and composites

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (42)

Show source-provided references
1. Nouri · 2015 · 3
2. Ti based biomaterials, the ultimate choice for orthopaedic implants-A review10.1016/j.pmatsci.2008.06.004 ↗
3. Novel porous Ti35Zr28Nb scaffolds fabricated by powder metallurgy with excellent osteointegration ability for bone-tissue engineering applications10.1016/j.msec.2019.110015 ↗
4. Bone density at the proximal femur after total hip arthroplasty
5. Metallurgical failure analysis of various implant materials used in orthopedic applications10.1007/s11668-996-0007-9 ↗
6. Microstructure, wear resistance, and corrosion performance of Ti35Zr28Nb alloy fabricated by powder metallurgy for orthopedic applications10.1016/j.jmst.2019.08.041 ↗
7. Fabrication and properties of newly developed Ti35Zr28Nb scaffolds fabricated by powder metallurgy for bone-tissue engineering10.1016/j.jmrt.2019.06.021 ↗
8. Mechanical properties, in vitro corrosion resistance and biocompatibility of metal injection molded Ti-12Mo alloy for dental applications10.1016/j.jmbbm.2018.08.038 ↗
9. Effect of Mo content on corrosion and tribocorrosion behaviours of Ti-Mo orthopaedic alloys fabricated by powder metallurgy10.1016/j.corsci.2020.108557 ↗
10. Structure and properties of cast binary Ti-Mo alloys10.1016/S0142-9612(99)00114-3 ↗
11. Porous Ti-10Mo alloy fabricated by powder metallurgy for promoting bone regeneration10.1007/s40843-018-9394-9 ↗
12. Electrochemical stability and corrosion resistance of Ti-Mo alloys for biomedical applications10.1016/j.actbio.2008.07.010 ↗
13. Effects of porosity on mechanical properties and corrosion resistance of PM-fabricated porous Ti-10Mo alloy10.3390/met8030188 ↗
14. The application of Ti-15Mo beta titanium alloy in high strength structural orthopaedic applications
15. Disegi · 2009
16. Beta titanium alloys and their role in the titanium industry
17. The treatment of fractures with a dynamic axial fixator10.1302/0301-620X.66B4.6746689 ↗
18. Infections associated with surgical implants10.1056/NEJM200407083510220 ↗
19. Modification of medical metals by ion implantation of copper10.1016/j.apsusc.2007.06.031 ↗
20. Influence of surface modifications to titanium on bacterial inhibitory activity in vitro10.1016/S0142-9612(00)00392-6 ↗
21. In vivo bacterial inhibitory property of Ti-Cu sintered alloy implant10.1016/j.msec.2019.02.084 ↗
22. Structure, and properties of Ti-Ag alloys produced by powder metallurgy10.1016/j.jallcom.2017.03.155 ↗
23. Fibroblast responses and bacterial inhibitory activity of Cu and Zn co-doped TiO2 for percutaneous implants10.1016/j.apsusc.2017.10.169 ↗
24. A novel bacterial inhibitory titania coating: metal ion toxicity and in vitro surface colonization
25. Osteogenic ability of Cu‐bearing stainless steel10.1002/jbm.b.33318 ↗
26. Applications of metals for bone regeneration10.3390/ijms19030826 ↗
27. Bacterial inhibitory effect of 317L stainless steel contained copper in the prevention of implant-related infection in vitro and in vivo10.1007/s10856-011-4427-z ↗
28. Prevention of pin tract infection with titanium-copper alloys10.1002/jbm.b.31412 ↗
29. A new bacterial inhibitory titanium-copper sintered alloy: preparation and bacterial inhibitory property10.1016/j.msec.2013.06.016 ↗
30. Bacterial inhibitory properties of Ti-6Al-4V-xCu alloys10.1016/j.jmst.2013.12.014 ↗
31. The mechanical properties and in vitro biocompatibility of pm-fabricated Ti-28Nb-35.Zr alloy for orthopedic implant applications10.3390/ma11040531 ↗
32. Fabrication of commercial pure Ti by selective laser melting using hydride-dehydride titanium powders treated by ball milling10.1016/j.jmst.2018.09.058 ↗
33. 2017
34. 1999
35. 2003
36. Rapid quenching of semisolid Ti-Cu alloys: insights into globular microstructure formation and coarsening10.1016/j.actamat.2017.08.006 ↗
37. In vitro study on an bacterial inhibitory Ti–5Cu alloy for medical application10.1007/s10856-016-5698-1 ↗
38. Mechanical properties of cast Ti‐6Al‐4V‐XCu alloys10.1111/j.1365-2842.2004.01347.x ↗
39. Optimization of mechanical property, bacterial inhibitory property and corrosion resistance of Ti-Cu alloy for dental implant10.1016/j.jmst.2019.03.044 ↗
40. Optimization of mechanical properties, biocorrosion properties and antibacterial properties of as-cast Ti-Cu alloys10.1088/1748-6041/11/6/065001 ↗
41. Study on bacterial inhibitory activity and cytocompatibility of Ti-6Al-4V-5Cu alloy10.1179/1753555714Y.0000000237 ↗
42. The bacterial inhibitory properties and biocompatibility of a Ti-Cu sintered alloy for biomedical application10.1088/1748-6041/9/2/025013 ↗