Evaluating metallic artefact of biodegradable magnesium-based implants in magnetic resonance imaging
Source abstract
Abstract
Magnesium (Mg) implants have shown to cause image artefacts or distortions in magnetic resonance imaging (MRI). Yet, there is a lack of information on how the degradation of Mg-based implants influences the image quality of MRI examinations. In this study, Mg-based implants are analysed in vitro, ex vivo, and in the clinical setting for various magnetic field strengths with the aim to quantify metallic artefact behaviour. In vitro corroded Mg-based screws and a titanium (Ti) equivalent were imaged according to the ASTM F2119. Mg-based and Ti pins were also implanted into rat femurs for different time points and scanned to provide insights on the influence of soft and hard tissue on metallic artefact. Additionally, MRI data of patients with scaphoid fractures treated with CE-approved Mg-based compression screws (MAGNEZIX®) were analysed at various time points post-surgery. The artefact production of the Mg-based material decreased as implant material degraded in all settings. The worst-case imaging scenario was determined to be when the imaging plane was selected to be perpendicular to the implant axis. Moreover, the Mg-based implant outperformed the Ti equivalent in all experiments by producing lower metallic artefact (p < 0.05). This investigation demonstrates that Mg-based implants generate significantly lower metallic distortion in MRI when compared to Ti. Our positive findings suggest and support further research into the application of Mg-based implants including post-operative care facilitated by MRI monitoring of degradation kinetics and bone/tissue healing processes.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Magnesium Alloys: Properties and Applications · Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (37)
Show source-provided references
1. Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?10.1136/heart.89.6.651 ↗
2. Kyphoplasty and vertebroplasty in the management of osteoporosis with subsequent vertebral compression fractures
3. Bioabsorbable magnesium screw versus conventional titanium screw fixation for medial malleolar fractures
4. Bioabsorbable magnesium versus standard titanium compression screws for fixation of distal metatarsal osteotomies – 3 year results of a randomized clinical trial10.1016/j.jos.2017.11.005 ↗
5. Bioabsorbable metal screws in traumatology: a promising innovation10.1016/j.tcr.2017.01.012 ↗
6. Investigation of mechanical and degradation properties of Mg-Sr and Mg-Zn-Sr alloys for use as potential biodegradable implants materials10.1016/j.jmbbm.2011.07.018 ↗
7. New prostate MRI techniques and sequences10.1007/s00261-020-02504-8 ↗
8. A comparison of the effectiveness of functional MRI analysis methods for pain research: the new normal10.1371/journal.pone.0243723 ↗
9. The increasing role of muscle MRI to monitor changes over time in untreated and treated muscle diseases10.1097/WCO.0000000000000851 ↗
10. Computed tomography and radiation: understanding the issues10.1016/j.jacr.2003.11.012 ↗
11. MRI saftey: a report of current practise and advancements in patient preparation and screening10.1016/j.clinimag.2015.09.002 ↗
12. Advances in MRI around metal10.1002/jmri.25708 ↗
13. The current performance of biodegradable magnesium-based implants in magnetic resonance imaging: a review
14. Azo Materials · 2013
15. ASTM standard F3268-18a
16. ASTM standard F2119-07
17. The ARRIVE guidelines 2.0: updated guidelines for reporting animal research
18. Magnetic resonance imaging—Cardiac ejection fraction measurements10.1097/00004424-199203000-00003 ↗
19. Comparison of SCAphoid fracture osteosynthesis by MAGnesium-based headless Herbert screws with titanium Herbert screws: protocol for the randomized controlled SCAMAG clinical trial10.1186/s12891-019-2723-9 ↗
20. SPIRIT 2013 statement: defining standard protocol items for clinical trials10.7326/0003-4819-158-3-201302050-00583 ↗
21. CONSORT 2010 Statement: updated guidelines for reporting parallel group randomised trials
22. Intervertebral test spacers and postfusion MRI artifacting: a comparative in vitro study of magnesium versus titanium and carbon fiber reinforced polymers as biomaterials10.2478/s11536-009-0027-4 ↗
23. Metal-induced artifacts in computed tomography and magnetic resonance imaging: comparison of a biodegradable magnesium alloy versus titanium and stainless steel controls10.1007/s00256-014-2057-5 ↗
24. Biodegradable magnesium Herbert
25. Review on titanium and titanium based alloys as biomaterials for orthopaedic applications10.1016/j.msec.2019.04.064 ↗
26. Magnesium degradation products: effects on tissue and human metabolism10.1002/jbm.a.35023 ↗
27. Composition of corrosion layers on a magnesium rare-earth alloy in simulated body fluids10.1002/jbm.a.31887 ↗
28. Magnesium degradation products: effects on tissue and human10.1002/jbm.a.35023 ↗
29. The interface between degradable Mg and tissue10.1007/s11837-019-03368-0 ↗
30. Susceptibility artefacts in NMR imaging10.1016/0730-725X(85)90397-2 ↗
31. International standard, medical equipment - Part 2: particular requirements for the safety of magnetic resonance equipment for medical diagnosis, 2nd Revision
32. Guidelines for limiting exporsure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz)
33. The effect of freeze-thawing on magnetic resonance imaging T2* of freshly harvested bovine patellar tendon
34. In vivo study of a biodegradable orthopedic screw (MgYREZr-alloy) in a rabbit model for up to 12 months10.1177/0885328212472215 ↗
35. Biodegradable magnesium implants for orthopedic applications10.1007/s10853-012-6572-2 ↗
36. Degradation rates of pure zinc, magnesium, and magnesium alloys measured by volume loss, mass loss, and hydrogen evolution10.3390/app8091459 ↗
37. Metal artefact reduction in MRI at both 1.5 and 3.0Tusing slice encoding for metal artefact correction and view angle tilting10.1259/bjr.20140601 ↗