High nitrogen stainless steel drug-eluting stent - Assessment of pharmacokinetics and preclinical safety in vivo
Source abstract
Abstract
Pharmacokinetic analyses were performed using 20 pigs for 120-days implantation, while one sirolimus-eluting stent was implanted into one of their coronary artery. At different time points, the residual sirolimus on the stent, delivered locally (to artery wall), regionally (to adjacent and downstream muscle) and systemically (to plasma and visceral organs), was detected throughout 120 days. Preclinical safety evaluation was performed using 32 pigs for 180-days implantation to study the safety of metal platform material and the effectiveness of sirolimus eluting coating on the HNS stent. The neointima area, restenosis rate and inflammatory grade for HNS and control group stents were detected and analyzed. Approximately 80% sirolimus was eluted from the sirolimus-eluting stents after 30-days implantation in vivo. Additionally, there was sustained sirolimus in the artery wall, cardiac muscle and heart throughout 120-days implantation, and sirolimus accumulated to the peak at 90-days implantation. It was inferred that the sirolimus eluting stent in this study was covered by neointima before 90-days implantation, indicating that the sirolimus eluting coating on the HNS stent was safe and effective. Very little sirolimus was distributed in visceral organs after 14-days implantation. HNS sirolimus-eluting stent exhibited lower restenosis rate and lower inflammatory grade than control group, which verified that the sirolimus-eluting coating design in this study was reasonable and practical. In addition, there were no significant difference in restenosis rate and inflammatory score between HNS bare-metal stent and drug-eluting stents, illustrating that HNS has good bio-compatibility and is suitable to use as coronary artery stent material.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Coronary Interventions and Diagnostics · Corrosion Behavior and Inhibition · Integrated Circuits and Semiconductor Failure Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (21)
Show source-provided references
1. Nickel free alloy for cardiovascular stents application against restenosis associated with nickel: a review10.1166/sam.2020.3725 ↗
2. In-situ observation of dynamic reacting species at pit precursors of nitrogen-bearing austenitic stainless steels10.2355/isijinternational.36.787 ↗
3. Nickel-free stainless steel avoids neointima formation following coronary stent implantation10.1088/1468-6996/13/6/064218 ↗
4. In vitro study of platelet adhesion on medical nickel-free stainless steel surface10.1016/j.matlet.2005.01.067 ↗
5. Influence of cold-worked structure on electrochemical properties of austenitic stainless steels10.1007/s11661-007-9224-4 ↗
6. Influence of cold work on pitting corrosion behavior of a high nitrogen stainless steel10.1149/1.2939213 ↗
7. Effect of cold deformation on pitting corrosion of 00Cr18Mn15Mo2N0.86 stainless steel for coronary stent application10.1016/j.msec.2015.11.048 ↗
8. Eliminating detrimental effect of cold working on pitting corrosion resistance in high nitrogen austenitic stainless steels10.1016/j.corsci.2017.04.006 ↗
9. Paclitaxel/sirolimus combination coated drug-eluting stent: in vitro and in vivo drug release studies10.1016/j.jpba.2010.10.027 ↗
10. Clinical use of sirolimus-eluting stents10.1111/j.1527-3466.2007.00024.x ↗
11. Clinical outcomes for sirolimus-eluting stent implantation and vascular brachytherapy for the treatment of in-stent restenosis, Catheter10.1002/ccd.20068 ↗
12. Long-term effectiveness of the zilver PTX drug-eluting stent for femoropopliteal peripheral artery disease in patients with No patent tibial runoff vessels—results from the zilver PTX Japan post-market surveillance study10.1016/j.jvir.2017.08.014 ↗
13. Ikeno · 2004 · 1139
14. Systemic and local tissue pharmacokinetics of single and overlapping NEVO™ sirolimus-eluting stents in the porcine coronary artery model
15. Polymer-free paclitaxel-coated zilver PTX stents-evaluation of pharmacokinetics and comparative safety in porcine arteries10.1016/j.jvir.2010.12.027 ↗
16. Paclitaxel/sirolimus combination coated drug-eluting stent: in vitro and in vivo drug release studies10.1016/j.jpba.2010.10.027 ↗
17. Study of drug-eluting coating on metal coronary stent10.1016/j.msec.2012.12.049 ↗
18. A novel immunosuppressor-sirolimus
19. Immunosuppressive effects and safety of a Sirolimus/cyclosporine combination regimen for renal transplantation10.1016/S0022-5347(05)68892-1 ↗
20. Stent thrombosis and major clinical events at 3 years after zotarolimus-eluting or sirolimus-eluting coronary stent implantation: a randomised, multicentre, open-label, controlled trial10.1016/S0140-6736(12)61336-1 ↗
21. Rapamycin: distribution, pharmacokinetics and therapeutic range investigations: an update10.1016/S0009-9120(98)00048-4 ↗