A mechatronic leg replica to benchmark human–exoskeleton physical interactions
Source abstract
Abstract
Abstract Evaluating human–exoskeleton interaction typically requires experiments with human subjects, which raises safety issues and entails time-consuming testing procedures. This paper presents a mechatronic replica of a human leg, which was designed to quantify physical interaction dynamics between exoskeletons and human limbs without the need for human testing. In the first part of this work, we present the mechanical, electronic, sensory system and software solutions integrated in our leg replica prototype. In the second part, we used the leg replica to test its interaction with two types of commercially available wearable devices, i.e. an active full leg exoskeleton and a passive knee orthosis. We ran basic test examples to demonstrate the functioning and benchmarking potential of the leg replica to assess the effects of joint misalignments on force transmission. The integrated force sensors embedded in the leg replica detected higher interaction forces in the misaligned scenario in comparison to the aligned one, in both active and passive modalities. The small standard deviation of force measurements across cycles demonstrates the potential of the leg replica as a standard test method for reproducible studies of human-exoskeleton physical interaction.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Prosthetics and Rehabilitation Robotics · Muscle activation and electromyography studies · Stroke Rehabilitation and Recovery
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (53)
Show source-provided references
1. State of the art and future directions for lower limb robotic exoskeletons10.1109/TNSRE.2016.2521160 ↗
2. Walking after stroke: does it matter? Changes in bone mineral density within the first 12 months after stroke. A longitudinal study10.1007/s001980070103 ↗
3. The ReWalk RestoreTM soft robotic exosuit: a multi-site clinical trial of the safety, reliability and feasibility of exosuit-augmented post-stroke gait rehabilitation10.1186/s12984-020-00702-5 ↗
4. A comparison between three commercially available exoskeletons in the automotive industry: an electromyographic pilot study10.1109/BioRob49111.2020.9224362 ↗
5. Standards for the safety of exoskeletons used by industrial workers performing manual handling activities: a contribution from the robo-mate project to their future development10.1016/j.promfg.2015.07.306 ↗
6. A systematic literature review of evidence for the use of assistive exoskeletons in defence and security use cases10.1080/00140139.2022.2059106 ↗
7. Design of a knee exoskeleton for gait assistance
8. Pons · 2008
9. Running with an elastic lower limb exoskeleton10.1123/jab.2015-0155 ↗
10. A biologically inspired soft exosuit for walking assistance10.1177/0278364914562476 ↗
11. Characterization and evaluation of human–exoskeleton interaction dynamics: a review10.3390/s22113993 ↗
12. Influence of attachment pressure and kinematic configuration on pHRI with wearable robots10.1155/2009/829219 ↗
13. Self-aligning exoskeleton axes through decoupling of joint rotations and translations10.1109/TRO.2009.2019147 ↗
14. Force transfer characterization of a soft exosuit for gait assistance10.1115/DETC2015-47871 ↗
15. Real-time strap pressure sensor system for powered exoskeletons10.3390/s150204550 ↗
16. ISO 13482:2014 and its confusing categories. Building a bridge between law and robotics10.1007/978-3-319-30674-2_3 ↗
17. Testing safety of lower limbs exoskeletons: current regulatory gaps10.1007/978-3-030-69547-7_24 ↗
18. Occurrence and type of adverse events during the use of stationary gait robots—a systematic literature review10.3389/frobt.2020.557606 ↗
19. Evaluation plan of a mechatronic system for anterior cruciate ligament rehabilitation10.1109/CCAC.2017.8276394 ↗
20. Test methods for exoskeletons—lessons learned from industrial and response robotics10.1049/PBCE108E_ch13 ↗
21. Development of an upper limb exoskeleton powered via pneumatic electric hybrid actuators with bowden cable10.1109/IROS.2014.6943062 ↗
22. An intelligent exoskeleton for lower limb rehabilitation10.1115/DETC2010-28022 ↗
23. Non-singular terminal sliding mode controller: application to an actuated exoskeleton10.1016/j.mechatronics.2015.10.012 ↗
24. Design methodology for soft wearable devices—the MOSAR case10.3390/app9224727 ↗
25. Mechanical design of a biomimetic compliant lower limb exoskeleton (biocomex)10.1109/ICARSC.2016.51 ↗
26. Simultaneous control framework for humanoid tracking human movement with interacting wearable assistive device10.1109/LRA.2020.2979663 ↗
27. Cybernetic human hrp-4c10.1109/ICHR.2009.5379537 ↗
28. Test method for contact safety assessment of a wearable robot-analysis of load caused by a misalignment of the knee joint10.1109/ROMAN.2012.6343807 ↗
29. Assessing effects of exoskeleton misalignment on knee joint load during swing using an instrumented leg simulator10.1186/s12984-022-00990-z ↗
30. Monitoring contact behavior during assisted walking with a lower limb exoskeleton10.1109/TNSRE.2020.2979986 ↗
31. A method for quantifying interaction forces in wearable robots10.1109/BIOROB.2018.8487701 ↗
32. Interaction forces beneath cuffs of physical assistant robots and their motion-based estimation10.1080/01691864.2015.1055799 ↗
33. Measurement of contact behavior including slippage of cuff when using wearable physical assistant robot10.1109/TNSRE.2015.2464719 ↗
34. Quantifying the human-robot interaction forces between a lower limb exoskeleton and healthy users10.1109/EMBC.2016.7590770 ↗
35. Experimental comfort assessment of an active exoskeleton interface10.1109/IRIS.2017.8250095 ↗
36. Analysis of human–exoskeleton system interaction for ergonomic design10.1177/0018720820913789 ↗
37. Fiber Bragg gratings in CYTOP fibers embedded in a 3D-printed flexible support for assessment of human–robot interaction forces10.3390/ma11112305 ↗
38. Polymer optical fiber-embedded, 3D-printed instrumented support for microclimate and human-robot interaction forces assessment10.1016/j.optlastec.2018.11.044 ↗
39. Clauser · 1969
40. Neumann · 2016
41. Gordon · 2014
42. Smarcos: off-the-shelf smart compliant actuators for human-robot applications10.3390/act10110289 ↗
43. Maccepa, the mechanically adjustable compliance and controllable equilibrium position actuator: design and implementation in a biped robot10.1016/j.robot.2007.03.001 ↗
44. Materials used to simulate physical properties of human skin10.1111/srt.12235 ↗
45. Human lower limb joint biomechanics in daily life activities: a literature based requirement analysis for anthropomorphic robot design10.3389/frobt.2020.00013 ↗
46. Lower limb angular velocity during walking at various speeds10.1016/j.gaitpost.2018.06.162 ↗
47. Investigating the effects of strapping pressure on human-robot interface dynamics using a soft robotic cuff10.1109/TMRB.2020.3042255 ↗
48. Relationship between interface pressures and pneumatic cuff inflation pressure at different assessment sites of the lower limb to aid soft exoskeleton design10.1177/0018720820908758 ↗
49. Human-like artificial skin sensor for physical human-robot interaction10.1109/ICRA48506.2021.9561152 ↗
50. The relative contributions of interface pressure, shear stress and temperature on tissue ischemia: a cross-sectional pilot study
51. Influence of shear on skin oxygen tension10.1111/j.1475-097X.1994.tb00495.x ↗
52. Challenges and solutions for application and wider adoption of wearable robots10.1017/wtc.2021.13 ↗
53. Eurobench: preparing robots for the real world10.1007/978-3-030-01887-0_72 ↗