Preparation and characterization of DNA array slides via surface Michael addition
Source abstract
Abstract
The reliability and stability of array slides are a big concern for array vendors and end users. Herein, we report on a new type of array slide with high reactivity toward DNA probes and low side reaction. A one-step surface reaction via the Michael addition involved in preparing array slides was developed and characterized by x-ray photoelectron spectroscopy, contact angle, and fluorescence labeling. The effects of array fabrication and storage conditions, i.e., spotting solution pH, high humidity, and long-term storage on the reactivity of the slides were examined. The fabricated DNA arrays could realize good hybridization efficiency (38.2% for slides with 0.88 pmol/cm2), low limit of detection (4 × 10−14M), as well as high mismatch selectivity.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced biosensing and bioanalysis techniques · Biosensors and Analytical Detection · Gene expression and cancer classification
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
State Key Laboratory of Fine Chemicals, Dalian University of Technology 1 , Dalian, Liaoning 116023, China
School of Chemical Engineering, Dalian University of Technology 2 , Dalian, Liaoning 116023, China
Funding
National Key Research and Development Program of China · National Natural Science Foundation of China · Fundamental Research Funds for the Central Universities
References (37)
Show source-provided references
1. Nat. Rev. Genet. · 2015 · 16 · 17210.1038/nrg3871 ↗
2. Nat. Biotechnol. · 2017 · 35 · 56110.1038/nbt.3853 ↗
3. Nat. Rev. Genet. · 2011 · 12 · 52910.1038/nrg3000 ↗
4. Genome Res. · 2009 · 19 · 168210.1101/gr.083501.108 ↗
5. Nat. Commun. · 2019 · 10 · 251210.1038/s41467-019-10540-2 ↗
6. J. Controlled Release · 2018 · 269 · 22510.1016/j.jconrel.2017.11.025 ↗
7. Nucleic Acids Res. · 2000 · 28 · 457710.1093/nar/28.22.4577 ↗
8. Food Control · 2019 · 101 · 8110.1016/j.foodcont.2019.02.014 ↗
9. Micromachines · 2019 · 10 · 21510.3390/mi10040215 ↗
10. Brief. Funct. Genomics · 2018 · 17 · 4210.1093/bfgp/elx017 ↗
11. Proc. Natl. Acad. Sci. U.S.A. · 2009 · 106 · 1909610.1073/pnas.0910672106 ↗
12. Lab Chip · 2019 · 19 · 44410.1039/C8LC01189C ↗
13. Rev. Sci. Instrum. · 2011 · 82 · 09430110.1063/1.3636077 ↗
14. Int. J. Electrochem. Sci. · 2013 · 8 · 1104810.1016/S1452-3981(23)13168-3 ↗
15. Chemistryselect · 2019 · 4 · 152510.1002/slct.201803464 ↗
16. Sens. Actuators B · 2018 · 274 · 45110.1016/j.snb.2018.07.163 ↗
17. Anal. Chem. · 2018 · 90 · 1122410.1021/acs.analchem.8b00265 ↗
18. Nucleic Acids Res. · 2008 · 36 · e710.1093/nar/gkm1103 ↗
19. Sens. Actuators B · 2019 · 284 · 23610.1016/j.snb.2018.12.132 ↗
20. Adv. Mater. Interfaces · 2018 · 5 · 180065910.1002/admi.201800659 ↗
21. Int. J. Biol. Macromol. · 2019 · 130 · 79810.1016/j.ijbiomac.2019.02.145 ↗
22. Mol. Pharm. · 2017 · 14 · 261610.1021/acs.molpharmaceut.7b00088 ↗
23. Acta Biomater. · 2016 · 40 · 27310.1016/j.actbio.2016.03.035 ↗
24. Langmuir · 2015 · 31 · 341310.1021/la504087a ↗
25. Biointerphases · 2017 · 12 · 02C41410.1116/1.4984305 ↗
26. ACS Sustain. Chem. Eng. · 2019 · 7 · 911210.1021/acssuschemeng.8b05550 ↗
27. RSC Adv. · 2016 · 6 · 6417510.1039/C6RA14046G ↗
28. Chem. Res. Toxicol. · 2017 · 30 · 187410.1021/acs.chemrestox.7b00196 ↗
29. Anal. Biochem. · 2000 · 280 · 14310.1006/abio.2000.4515 ↗
30. Sensors · 2018 · 18 · 313810.3390/s18093138 ↗
31. Anal. Biochem. · 1997 · 251 · 27010.1006/abio.1997.2254 ↗
32. Nat. Chem. Biol. · 2014 · 10 · 47010.1038/nchembio.1525 ↗
33. Nat. Methods · 2005 · 2 · 84510.1038/nmeth808 ↗
34. Carbohydr. Res. · 2019 · 481 · 3110.1016/j.carres.2019.06.006 ↗
35. Biomed. Microdevices · 2008 · 10 · 20310.1007/s10544-007-9126-7 ↗
36. J. Biomed. Opt. · 2014 · 19 · 05120910.1117/1.JBO.19.5.051209 ↗
37. See supplementary material at https://doi.org/10.1063/1.5124411 for the static water angle before and after treatment with DVS, chemical structure of Cy3, relative fluorescence intensity of the VS slides prepared with different organocatalysts, XPS data collected on silicon wafers, and fluorescence intensity of the VS-treated glass slides and silicon wafers.