journal article·2016-12-01

Improved 3D-imaging of a sirolimus/probucol eluting stent coating using laser postionization secondary neutral mass spectrometry and time-of-flight secondary ion mass spectrometry

Andreas Pelster, Bonnie J. Tyler, Martin Körsgen, Rainer Kassenböhmer, Richard E. Peterson, Michael Stöver, Wolfgang E. S. Unger, Heinrich F. Arlinghaus

Biointerphases· Volume 11· Issue 4
Publisher page

Abstract

Implantable drug delivery systems that provide controlled and sustained release of a therapeutic agent are used in a wide variety of applications. Drug eluting stents, which are used to treat coronary artery disease, are among the most widespread of these devices, with an estimated 3 × 106 implants annually worldwide. Controlling the rate of drug release from these devices relies on precise control of the three dimensional (3D)-distribution of the drug, so methods for measuring this distribution are of great importance. The aims of this work were to determine how 3D-imaging of polymer-free sirolimus/probucol drug eluting stent coatings could be improved through the use of laser postionization secondary neutral mass spectrometry (Laser-SNMS) and Ar cluster sputtering with time-of-flight secondary ion mass spectrometry (ToF-SIMS) and to optimize conditions for this analysis. In this study, 3D-imaging of a sirolimus/probucol dual drug eluting stent has been investigated using Laser-SNMS and ToF-SIMS. Laser-SNMS studies of pure sirolimus and probucol were undertaken using 30 keV Bi3+ primary ions and a 157 nm excimer postionization laser. Under optimal conditions, a greater than 100-fold increase in detected ion yield was observed for Laser-SNMS when compared to ToF-SIMS, although ToF-SIMS provided equal or greater yields for higher mass characteristic ions. Although the optimal laser power density for detecting probucol (5 × 106 W/cm2) was significantly lower than the optimum for sirolimus (7 × 107 W/cm2), an intermediate laser power density of 1 × 107 W/cm2 was sufficient to allow imaging of both drugs. Using individual selected ion signals, ToF-SIMS and Laser-SNMS produced similar images of the two drug species. When using, however, a multivariate approach (maximum autocorrelation factors), Laser-SNMS provided significant improvements in image contrast and small area detection when compared to ToF-SIMS. Following optimization of the technique, 3D-images of the dual drug eluting stent coating were obtained using 10 keV Ar2000+ cluster ions for sputtering and 30 keV Bi3+ cluster ions for analysis for both ToF-SIMS and Laser-SNMS. This work demonstrates the advantages of Laser-SNMS for 3D-imaging of pharmaceutical devices, which has not been previously published. Both ToF-SIMS and Laser-SNMS revealed that the outermost surface of the drug eluting coating contained pure sirolimus to a depth of a few tens of nanometers, with a few channels of sirolimus extending to a depth of around 1 μm. Below about 1 μm, the two drugs were uniformly mixed. Using the 10 keV Ar2000+ sputter beam, the authors were able to sputter through the complete drug coating (∼6 μm) without observing any accumulated damage in the organic layer. The two techniques showed complementary strengths: ToF-SIMS offers faster data collection and better detected ion yield for larger characteristic ions than Laser-SNMS, and Laser-SNMS offers significantly enhanced detected ion yield for smaller fragment ions, allowing for improved image contrast and resolution of smaller features.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Ion-surface interactions and analysis · Integrated Circuits and Semiconductor Failure Analysis · Diamond and Carbon-based Materials Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

University of Münster Physikalisches Institut, , Wilhelm-Klemm-Str. 10, 48149 Münster, Germany

University of Münster Physikalisches Institut, , Wilhelm-Klemm-Str. 10, 48149 Münster, Germany and , Hampton Road, Teddington, Middlesex TW11 0LW, United Kingdom

National Physical Laboratory Physikalisches Institut, , Wilhelm-Klemm-Str. 10, 48149 Münster, Germany and , Hampton Road, Teddington, Middlesex TW11 0LW, United Kingdom

Aesculap Division-Vascular Systems B. Braun Melsungen AG, , Sieversufer 8, 12359 Berlin, Germany

BAM–Federal Institute for Materials Research and Testing , Unter den Eichen 44-46, 12205 Berlin, Germany

Funding

EURAMET

References (28)

Show source-provided references
1. J. Am. Coll. Cardiol. Intervention · 2010 · 3 · 7610.1016/j.jcin.2009.10.016 ↗
2. Circulation · 2001 · 103 · 19210.1161/01.CIR.103.2.192 ↗
3. Circulation · 2003 · 107 · 38110.1161/01.CIR.0000051720.59095.6D ↗
4. N. Engl. J. Med. · 2002 · 346 · 177310.1056/NEJMoa012843 ↗
5. Annu. Rev. Med. · 2004 · 55 · 16910.1146/annurev.med.55.091902.105243 ↗
6. Bioconjugate Chem. · 2015 · 26 · 127710.1021/acs.bioconjchem.5b00192 ↗
7. JACC · 2010 · 55 · 253610.1016/j.jacc.2010.03.020 ↗
8. Circulation · 2011 · 124 · 62410.1161/CIRCULATIONAHA.111.026732 ↗
9. Appl. Surf. Sci. · 2004 · 231–232 · 37710.1016/j.apsusc.2004.03.103 ↗
10. Mass Spectrom. Rev. · 2010 · 29 · 24710.1002/mas.20233 ↗
11. J. Controlled Release · 2008 · 126 · 11110.1016/j.jconrel.2007.11.015 ↗
12. Anal. Chem. · 2008 · 80 · 62410.1021/ac701644j ↗
13. Anal. Chem. · 2009 · 81 · 993010.1021/ac901587k ↗
14. J. Phys. Chem. B · 2008 · 112 · 259610.1021/jp077325n ↗
15. Anal. Chem. · 2013 · 85 · 506410.1021/ac4003535 ↗
16. Anal. Chem. · 2010 · 82 · 9810.1021/ac901045q ↗
17. Rapid Commun. Mass Spectrom. · 2009 · 23 · 160110.1002/rcm.4046 ↗
18. Surf. Interface Anal. · 2013 · 45 · 17110.1002/sia.5122 ↗
19. J. Am. Soc. Mass Spectrom. · 2016 · 27 · 27710.1007/s13361-015-1275-y ↗
20. Biointerphases · 2016 · 11 · 02A30510.1116/1.4937466 ↗
21. Surf. Interface Anal. · 2013 · 45 · 3110.1002/sia.4962 ↗
22. Anal. Chem. · 2012 · 84 · 7610.1021/ac2008338 ↗
23. J. Atheroscler. Thromb. · 2008 · 15 · 30410.5551/jat.E621 ↗
24. J. Phys. Chem. C · 2013 · 117 · 1262210.1021/jp402684c ↗
25. Surf. Interface Anal. · 2014 · 46 · 58110.1002/sia.5543 ↗
26. Surf. Interface Anal. · 2013 · 45 · 47510.1002/sia.5106 ↗
27. J. Vac. Sci. Technol., A · 1994 · 12 · 40510.1116/1.579255 ↗
28. Biomaterials · 2007 · 28 · 241210.1016/j.biomaterials.2007.02.002 ↗