Mechanical properties of completely autologous human tissue engineered blood vessels compared to human saphenous vein and mammary artery
Source abstract
Abstract
We have previously reported the initial clinical feasibility with our small diameter tissue engineered blood vessel (TEBV). Here we present in vitro results of the mechanical properties of the TEBVs of the first 25 patients enrolled in an arterio-venous (A-V) shunt safety trial, and compare these properties with those of risk-matched human vein and artery. TEBV average burst pressures (3490+/-892 mmHg, n=230) were higher than native saphenous vein (SV) (1599+/-877 mmHg, n=7), and not significantly different from native internal mammary artery (IMA) (3196+/-1264 mmHg, n=16). Suture retention strength for the TEBVs (152+/-50 gmf) was also not significantly different than IMA (138+/-50 gmf). Compliance for the TEBVs prior to implantation (3.4+/-1.6%/100 mmHg) was lower than IMA (11.5+/-3.9%/100 mmHg). By 6 months post-implant, the TEBV compliance (8.8+/-4.2%/100 mmHg, n=5) had increased to values comparable to IMA, and showed no evidence of dilation or aneurysm formation. With clinical time points beyond 21 months as an A-V shunt without intervention, the mechanical tests and subsequent lot release criteria reported here would seem appropriate minimum standards for clinical use of tissue engineered vessels.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Electrospun Nanofibers in Biomedical Applications · Tissue Engineering and Regenerative Medicine · Cardiac and Coronary Surgery Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (42)
Show source-provided references
1. Superiority of autogenous arteriovenous hemodialysis access: maintenance of function with fewer secondary interventions10.1007/s10016-003-0094-y ↗
2. Conduit options in coronary artery bypass surgery10.1378/chest.108.4.1150 ↗
3. The pathology of vascular grafts
4. Expanded PTFE prostheses as arterial substitutes in humans: late pathological findings in 73 excised grafts10.1007/BF03187341 ↗
5. Morphology of healing in vascular prostheses10.1055/s-2007-1020371 ↗
6. Cellular proliferation and macrophage populations associated with implanted expanded polytetrafluoroethylene and polyethyleneterephthalate10.1002/(SICI)1097-4636(20000315)49:4<489::AID-JBM7>3.0.CO;2-2 ↗
7. Vascular graft healing. III. FTIR analysis of ePTFE graft samples from implanted bigrafts10.1002/jbm.b.30044 ↗
8. The mechanical properties of infrainguinal vascular bypass grafts: their role in influencing patency10.1016/j.ejvs.2006.01.006 ↗
9. 2007
10. A blood vessel model constructed from collagen and cultured vascular cells10.1126/science.2934816 ↗
11. Development of a composite degradable/nondegradable tissue-engineered vascular graft10.1111/j.1525-1594.2008.00601.x ↗
12. A self-renewing, tissue-engineered vascular graft for arterial reconstruction10.1016/j.jtcvs.2007.06.039 ↗
13. Tissue engineering of a hybrid bypass graft for coronary and lower limb bypass surgery10.1096/fj.07-096586 ↗
14. A completely biological tissue-engineered human blood vessel
15. Dog peritoneal and pleural cavities as bioreactors to grow autologous vascular grafts10.1016/j.jvs.2003.03.003 ↗
16. Development of a tissue-engineered vascular graft combining a biodegradable scaffold, muscle-derived stem cells and a rotational vacuum seeding technique10.1016/j.biomaterials.2007.10.044 ↗
17. Transplantation of a tissue-engineered pulmonary artery10.1056/NEJM200102153440717 ↗
18. Human tissue-engineered blood vessels for adult arterial revascularization10.1038/nm1364 ↗
19. Blood vessels engineered from human cells10.1016/S0140-6736(05)66735-9 ↗
20. Tissue-engineered blood vessel for adult arterial revascularization10.1056/NEJMc071536 ↗
21. ANSI/AAMI/ISO 7198:1998/2001. Cardiovascular implants – tubular vascular prostheses; 2001.
22. Dynamic mechanical conditioning of collagen–gel blood vessel constructs induces remodeling in vitro10.1114/1.275 ↗
23. Small-diameter artificial arteries engineered in vitro10.1161/01.RES.0000196867.12470.84 ↗
24. Developments towards tissue-engineered, small-diameter arterial substitutes10.1586/17434440.5.3.337 ↗
25. Functional arteries grown in vitro10.1126/science.284.5413.489 ↗
26. Midterm clinical result of tissue-engineered vascular autografts seeded with autologous bone marrow cells10.1016/j.jtcvs.2004.12.047 ↗
27. Determination of layer-specific mechanical properties of human coronary arteries with nonatherosclerotic intimal thickening and related constitutive modeling10.1152/ajpheart.00934.2004 ↗
28. Autologous endothelialized vein allograft: a solution in the search for small-caliber grafts in coronary artery bypass graft operations10.1161/hc37t1.094527 ↗
29. Decellularized vein as a potential scaffold for vascular tissue engineering10.1016/j.jvs.2004.03.033 ↗
30. Bone tissue-engineered implants using human bone marrow stromal cells: effect of culture conditions and donor age10.1089/107632702320934010 ↗
31. Tissue engineering applications to vascular bypass graft development: the use of adipose-derived stem cells10.1016/j.jvs.2007.02.046 ↗
32. Production of extracellular matrix components in tissue-engineered blood vessels10.1089/ten.2006.12.831 ↗
33. Determinants of successful synthetic hemodialysis vascular access graft placement10.1067/mva.2003.257 ↗
34. Effect of aneurysm on the tensile strength and biomechanical behavior of the ascending thoracic aorta10.1016/S0003-4975(02)04711-2 ↗
35. Fabrication of cell microintegrated blood vessel constructs through electrohydrodynamic atomization10.1016/j.biomaterials.2007.02.012 ↗
36. Human arteries engineered in vitro10.1038/sj.embor.embor847 ↗
37. Material and structural characterization of human saphenous vein10.1016/0741-5214(90)90005-U ↗
38. Composite fibrin scaffolds increase mechanical strength and preserve contractility of tissue engineered blood vessels10.1007/s11095-007-9499-6 ↗
39. Fibrin-based tissue-engineered blood vessels: differential effects of biomaterial and culture parameters on mechanical strength and vascular reactivity10.1089/ten.2005.11.991 ↗
40. Role of mechanics in vascular tissue engineering
41. Tissue engineering of aortic tissue: dire consequence of suboptimal elastic fiber synthesis in vivo10.1016/j.cardiores.2004.05.002 ↗
42. Mechanical properties and compositions of tissue engineered and native arteries10.1007/s10439-006-9226-1 ↗