journal article·2007-05

Assessment of bone ingrowth into porous biomaterials using MICRO-CT

Anthony C. Jones, Christoph H. Arns, Adrian P. Sheppard, Dietmar W. Hutmacher, Bruce K. Milthorpe, Mark A. Knackstedt

Biomaterials· Volume 28· Issue 15
Publisher page

Abstract

The three-dimensional (3D) structure and architecture of biomaterial scaffolds play a critical role in bone formation as they affect the functionality of the tissue-engineered constructs. Assessment techniques for scaffold design and their efficacy in bone ingrowth studies require an ability to accurately quantify the 3D structure of the scaffold and an ability to visualize the bone regenerative processes within the scaffold structure. In this paper, a 3D micro-CT imaging and analysis study of bone ingrowth into tissue-engineered scaffold materials is described. Seven specimens are studied in this paper; a set of three specimens with a cellular structure, varying pore size and implant material, and a set of four scaffolds with two different scaffold designs investigated at early (4 weeks) and late (12 weeks) explantation times. The difficulty in accurately phase separating the multiple phases within a scaffold undergoing bone regeneration is first highlighted. A sophisticated three-phase segmentation approach is implemented to develop high-quality phase separation with minimal artifacts. A number of structural characteristics and bone ingrowth characteristics of the scaffolds are quantitatively measured on the phase separated images. Porosity, pore size distributions, pore constriction sizes, and pore topology are measured on the original pore phase of the scaffold volumes. The distribution of bone ingrowth into the scaffold pore volume is also measured. For early explanted specimens we observe that bone ingrowth occurs primarily at the periphery of the scaffold with a constant decrease in bone mineralization into the scaffold volume. Pore size distributions defined by both the local pore geometry and by the largest accessible pore show distinctly different behavior. The accessible pore size is strongly correlated to bone ingrowth. In the specimens studied a strong enhancement of bone ingrowth is observed for pore diameters>100 microm. Little difference in bone ingrowth is measured with different scaffold design. This result illustrates the benefits of microtomography for analyzing the 3D structure of scaffolds and the resultant bone ingrowth.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Drilling and Well Engineering

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (44)

Show source-provided references
1. Application of porous ceramics for the attachment of load bearing internal orthopedic applications10.1002/jbm.820050613 ↗
2. Porosity of 3D biomaterial scaffolds and osteogenesis10.1016/j.biomaterials.2005.02.002 ↗
3. Pore throat size and connectivity determine bone and tissue ingrowth into porous implants: three dimensional micro-CT based structural analyses of porous bioactive titanium implants10.1016/j.biomaterials.2006.08.013 ↗
4. In vivo regeneration with injectable calcium phosphate biomaterial: a three-dimensional micro-computed tomographic, biomechanical and SEM study10.1016/j.biomaterials.2005.01.072 ↗
5. A comparison of micro CT with other techniques used in the characterization of scaffolds10.1016/j.biomaterials.2005.08.035 ↗
6. 3-D computational modeling of media flow through scaffolds in a perfusion bioreactor10.1016/j.jbiomech.2004.04.011 ↗
7. Structure and properties of clinical coralline implants measured via 3D imaging and analysis10.1016/j.biomaterials.2005.12.016 ↗
8. Qualitative and quantitative analysis of 3D bone ingrowth into polymer scaffolds via micro-computed tomography10.1016/j.biomaterials.2004.01.047 ↗
9. Investigation of microstructural features in regenerating bone using micro-computed Tomography10.1023/B:JMSM.0000021133.48661.62 ↗
10. Scaffolds in tissue engineering bone and cartilage10.1016/S0142-9612(00)00121-6 ↗
11. An X-ray tomography facility for a wide range of mesoscale physics applications
12. X-ray tomography for mesoscale physics applications10.1016/j.physa.2004.03.055 ↗
13. Currey · 2002
14. Prendergast · 2001 · 32.2
15. Boskey · 2001
16. Optimal segmentation of microcomputed tomographic images of porous tissue-engineered scaffolds10.1002/jbm.a.30498 ↗
17. The relationship between three-dimensional connectivity and the elastic properties of trabecular bone10.1359/jbmr.1998.13.5.839 ↗
18. The influence of microcomputed tomography threshold variations on the assessment of structural and mechanical trabecular bone properties10.1016/S8756-3282(02)00782-2 ↗
19. Local differences in the trabecular bone structure of the proximal femur depicted with high-spatial-resolution MR imaging and multisection CT10.1016/S1076-6332(03)80667-0 ↗
20. Techniques for image enhancement and segmentation of tomographic images of porous materials10.1016/j.physa.2004.03.057 ↗
21. Snakes—active contour models10.1007/BF00133570 ↗
22. Limaye A. Drishti. [Online]. 2006 [cited 2006 August 5]. Available from 〈URL:http://anusf.anu.edu.au/~acl900/Drishti/index.html〉.
23. Virtual permeametry on microtomographic images10.1016/j.petrol.2004.05.001 ↗
24. Cormen · 2001
25. Gonzalez · 2002
26. Percolation and cluster distribution. I. Cluster multiple labeling technique and critical concentration algorithm10.1103/PhysRevB.14.3438 ↗
27. Bioceramic bone graft substitutes: influence of porosity and chemistry10.1111/j.1744-7402.2005.02020.x ↗
28. Serra · 1982
29. A new method for the model-independent assessment of thickness in three-dimensional images10.1046/j.1365-2818.1997.1340694.x ↗
30. Pore-morphology based simulation of drainage in totally wetting porous media10.1016/S0309-1708(00)00056-7 ↗
31. Grain reconstruction of porous media: application to a low-porosity Fontainebleau sandstone10.1103/PhysRevE.63.061307 ↗
32. Properties of osteoconductive biomaterials: calcium phosphates10.1097/00003086-200202000-00009 ↗
33. Degradation of calcium phosphate ceramics10.1002/(SICI)1097-4636(199901)44:1<78::AID-JBM9>3.0.CO;2-6 ↗
34. Combination of topological parameters and bone volume fraction better predicts the mechanical properties of trabecular bone10.1016/S0021-9290(02)00060-X ↗
35. Flow in porous media—pore-network models and multiphase flow10.1016/S1359-0294(01)00084-X ↗
36. Direct and stochastic generation of network models from tomographic images; effect of topology on residual saturations10.1023/A:1015034924371 ↗
37. Sheppard AP, Sok RM, Averdunk H. Improved pore network extraction methods. In: Proceedings of society of core analysts, Toronto, 21–25 August 2005.
38. Theoretical model to determine the effects of geometrical factors on the resorption of calcium phosphate bone substitutes10.1016/j.biomaterials.2003.10.032 ↗
39. Osteoconduction in large macroporous hydroxyapatite ceramic implants: evidence for a complementary integration and disintegration mechanism10.1016/S8756-3282(99)00083-6 ↗
40. Three-dimensional in vivo morphometry of trabecular bone in the OVX rat model of osteoporosis10.3233/THC-1998-65-607 ↗
41. Bone formation during forelimb regeneration: a microtomographic (MicroCT) analysis10.1002/dvdy.10241 ↗
42. Cellular accommodation and the response of bone to mechanical loading10.1016/j.jbiomech.2004.08.017 ↗
43. Computation of linear elastic properties from microtomographic images: methodology and agreement between theory and experiment10.1190/1.1512785 ↗
44. Modeling evaluation of the fluid-dynamic microenvironments in tissue engineered constructs: a micro-CT based model10.1002/bit.20740 ↗