journal article·2008-02

Medical applications of poly(styrene-block-isobutylene-block-styrene) (“SIBS”)

Leonard Pinchuk, Gregory J. Wilson, James J. Barry, Richard T. Schoephoerster, Jean-Marie Parel, Joseph P. Kennedy

Biomaterials· Volume 29· Issue 4
Publisher page

Abstract

Poly(Styrene-block-IsoButylene-block-Styrene) ("SIBS") is a biostable thermoplastic elastomer with physical properties that overlap silicone rubber and polyurethane. Initial data collected with SIBS stent-grafts and coatings on metallic stents demonstrate hemocompatibility, biocompatibility and long-term stability in contact with metal. SIBS has been used successfully as the carrier for a drug-eluting coronary stent; specifically Boston Scientific's TAXUS stent, and its uses are being investigated for ophthalmic implants to treat glaucoma, synthetic heart valves to possibly replace tissue valves and other applications. At present, researchers developing medical devices utilizing SIBS have found the following: (1) SIBS does not substantially activate platelets in the vascular system; (2) polymorphonuclear leukocytes in large numbers are not commonly observed around SIBS implants in the vascular system or in subcutaneous implants or in the eye; (3) myofibroblasts, scarring and encapsulation are not clinically significant with SIBS implanted in the eye; (4) embrittlement has not been observed in any implant location; (5) calcification within the polymer has not been observed; and (6) degradation has not been observed in any living system to date. Some deficiencies of SIBS that need to be addressed include creep deformation in certain load-bearing applications and certain sterilization requirements. The reason for the excellent biocompatibility of SIBS may be due to the inertness of SIBS and lack of cleavable moieties that could be chemotactic towards phagocytes.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Coronary Interventions and Diagnostics · Orthopaedic implants and arthroplasty · Advanced Polymer Synthesis and Characterization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (66)

Show source-provided references
1. A review of the biostability and carcinogenicity of polyurethanes in medicine and the new generation of biostable polyurethanes10.1163/156856294X00347 ↗
2. Human plasma α2-macroglobulin promotes in vitro oxidative stress cracking of pellethane 2363-80A: in vivo and in vitro correlations10.1002/jbm.820270311 ↗
3. Pinchuk L, Crack prevention of implanted prostheses; grafting a siloxane elastomer onto biocompatible surface. US patent no 4851009, 1989.
4. Pinchuk L, Esquivel MC, Martin Jr. JB. Polyurethane/silicone composites for long-term implant in the human body. In: Proceedings of the society of plastic engineerings ANTEC, Montreal, May 1991. p. 1802–4.
5. Adhikari R, Gunatillake PA, Maijs GF, Martin DJ, Poole-Warren LA, Schindhelm K. Synthesis and biostability of low modulus siloxane-based polyurethanes. Transactions of the society for biomaterials: sixth world biomaterials congress, Minneapolis, part II, 2000, 812pp.
6. Ward RS, Tian Y, Chen Q, Nguyen C, Serpilio J. High strength, optically clear, silicone-urethane thermoplastics for biomedical use: bulk properties. Transactions of the society for biomaterials: sixth world biomaterials congress, Minneapolis, part I, 2000, 431pp.
7. Christenson EM, Anderson JM, et al. the effect of silicone on the biostability of poly(ether urethanes). Transactions of the society for biomaterials: 28th annual meeting, Tampa, Florida, April 24 to 27, 2002.
8. Ebert M, Ward R, Anderson J, Tain Y, McVenes R, Stokes K. Chronic Environmental Stress Cracking Resistance of Polyurethanes with Polyether and Polysiloxane Soft Segments. Society of Biomaterials: 29th Annual Meeting Transactions, 2003. p. 535.
9. Ebert M, Ward R, Anderson J, Tain Y, McVenes R, Stokes K. Screening of polyurethanes with polyether and polysiloxane soft segments for resistance to environmental stress cracking. society of biomaterials: 29th annual meeting transactions, 2003, 542pp.
10. Ebert M, Ward R, Anderson J, Tain Y, McVenes R, Stokes K. Chronic. Environmental stress cracking resistance of polyetherurethanes with fluorocarbon surface modifying endgroups. society of biomaterials: 29th annual meeting transactions, 2003, 538pp.
11. Ebert M, Ward R, Anderson J, Tain Y, McVenes R, Stokes K. Chronic environmental stress cracking resistance of polyetherurethanes with polyethyleneoxide surface modifying endgroups. society of biomaterials: 29th annual meeting transactions, 2003, 536pp.
12. An FTIR-ATR investigation of in vivo poly(ether urethane) degradation10.1002/app.1992.070460202 ↗
13. Cell/polymer interactions in the biodegradation of polyurethanes
14. Pinchuk, L. Crack-resistant polycarbonate urethane polymer prostheses. US patent no 5133742, 1992.
15. Pinchuk L, Kato YP, Eckstein ML, Wilson GJ, MacGregor DC. Polycarbonate urethanes as elastomeric materials for long-term implant applications. Transactions of the 19th annual meeting of the society for biomaterials. Birmingham, AL, 1993, 22pp.
16. MacGregor DC, Wilson GJ, Klement P, Weber BA, Binnington AG, Pinchuk L. A new compliant composite elastomer/dacron small caliber vascular prosthesis. Transactions of the 17th annual meeting of the society for biomaterials, vol. 14. Scottsdale, AZ, 1991, 145pp.
17. The composite corethane/dacron vascular prosthesis: canine in vivo evaluation of 4mm diameter grafts with 1 year follow-up
18. Wilson GJ, Klement P, Kato YP, Omar S, Wilson P, Bridgeman J, et al. Healing of a self-expanding bifurcated vascular graft for abdominal aortic aneurysm repair in dogs. Transactions of the 44th annual conference asaio/cvst, april 1998.
19. Glass wool-H2O2/CoCl2 test system for in vitro evaluation of biodegradable stress cracking in polyurethane elastomers10.1002/jbm.820290406 ↗
20. Wear of polyethylene acetabular components in total hip arthroplasty. An analysis of one hundred and twenty-eight components retrieved at autopsy or revision operations.10.2106/00004623-199703000-00005 ↗
21. Kurtz · 2004
22. Wright · 2001
23. Otto Aufranc award paper: significance of in vivo degradation for polyethylene in total hip arthroplasty10.1097/01.blo.0000246547.18187.0b ↗
24. Deacon J, Apple DJ. Further studies of IOL materials. In: Proceedings of the 11th annual meeting of the society for biomaterials. San Diego, CA: University of Alabama, Birmingham; 1985. 205pp.
25. Goldberg EP, Yalon M, Stacholy J, Kurobe N, Longo WE, Osborn DC, et al. Biocompatibility of intraocular lens polymers. In: Proceedings of the 11th annual meeting of the society for biomaterials. San Diego, CA: University of Alabama, Birmingham; 1985. 208pp.
26. Biocompatibility of implant materials: a review and scanning electron microscopy study10.1016/S0146-2776(84)80079-8 ↗
27. From thermoplastic elastomers to designed biomaterials
28. Pinchuk L. Biostable elastomeric polymers having quaternary carbons. US patent no 5741331, 1998.
29. Pinchuk L. Method of implanting biostable elastomeric polymers having quaternary carbons. US patent no 6102939, 2000.
30. Pinchuk L. Method of device having biostable elastomeric polymers having quaternary carbons. US patent no 6197240, 2001.
31. Living carbocationic polymerization XII. Telechelic polyisobutylenes by a sterically hindered bifunctional initiator10.1007/BF00285351 ↗
32. Living carbocationic polymerization VIII. Telechelic polyisobutylenes by the MeO(CH2)2C-p-C5H4-C(CH3)2Ome/BCl3 initiating system10.1007/BF00955877 ↗
33. Liebhafsky · 1978
34. Pinchuk L, Khan IJ, Martin JB, Bridgeman J, Wilson GJ, Glass J, et al. A new family of thermoplastic elastomers for ultra-long term implant based upon a backbone of alternating quaternary and secondary carbons. Transactions of the 44th annual conference ASAIO/CVST, 1998.
35. Pinchuk L, Khan IJ, Martin JB, Wilson GJ. Polyisobutylene-based thermoplastic elastomers for ultra long term implant applications. Transactions of the society of biomaterials, sixth world biomaterials congress transactions, Hawaii, 2000, 1452pp.
36. Steckel M, Richard RE, Straumann P, Barry JJ. In vivo biostability of SIBS controlled release polymer in the taxustm drug-eluting coronary stents. Transactions of biomaterials in regenerative medicine: the advent of combination products, October 16–18, Philadelphia, PA, 2004, 42pp.
37. The TAXUSTM drug eluting stent: a new paradigm in controlled drug delivery10.1016/j.addr.2006.01.023 ↗
38. Kamath KR, Barry JJ. The utilization of antiproliferative and antimigratory compounds for the prevention of restenosis. In: Kipshidze N, Fareed J, Moses J, Serruys P, editors. Textbook of Interventional cardiovascular pharmacology. Informa Healthcare, London, Boca Raton, FL: Taylor & Francis; 2007. p. 299–314.10.3109/9780203463048-26 ↗
39. Pinchuk L, Nott S, Schwarz M, Kamath K. Drug delivery compositions and medical devices containing block copolymer. US patent no 6545097, 2003.
40. Richard RE, Barry JJ, Kamath K, Miller K, Renade SV, Schwarz M. Polymer technology for the controlled release of paclitaxel from a vascular compatible matrix—the TAXUSTM express paclitaxel-eluting coronary stent. Transactions of biomaterials in regenerative medicine: the advent of combination products, October 16–18, Philadelphia, PA, 2004. p. 9–10.
41. Physical characterization of controlled release of Paclitaxel from the TAXUS™ Express2™ drug-eluting stent10.1002/jbm.a.30188 ↗
42. Styrenic block copolymers for biomaterial and drug delivery applications10.1016/j.actbio.2004.09.004 ↗
43. Safety and efficacy of sirolimus- and paclitaxel-eluting coronary stents10.1056/NEJMoa067193 ↗
44. Schwartz MC, Ranade SV, Richard RE. Controlled delivery of paclitaxel from stent coatings containing styrene maleic anhydride polymer blends. In: 31st Annual meeting of the controlled release society, 12–16 June, Honolulu, Hawaii, USA, 2004.
45. Synthesis and characterization, propertues, and drug release of poly(alkyl methacrylate-b-isobutylene-b-alkyl methacrylate)10.1021/bm0604496 ↗
46. Initial experience with paclitaxel-coated stents10.1111/j.1540-8183.2002.tb01091.x ↗
47. TAXUS clinical trials: TCT recap
48. High-dose 7-hexanoltaxol-eluting stent with polymer sleeves for coronary revascularization: one year results from the SCORE randomized trial
49. Paclitaxel-eltuting stents: are they all equal? An analysis of randomized controlled trials in de novo lesions of 3319 patients10.1046/j.1540-8183.2003.01065.x ↗
50. The state of coronary drug-eluting stent use. current issues in DES care
51. Christy P, editor-in-chief. The state of coronary drug-eluting stent use: FDA panel addresses late stent thrombosis in DES, Card Interventions Today, 2007;1(1):44–52.
52. Acosta AC, Fernandez V, Lamar P, Orozco M, Dubovy S, Stoiber J, Pinchuk L, et al. Ocular biocompatibility of quatromer (polystyrene-polystyrene triblock polymers) for glaucoma applications. Invest Ophthalmol Vis Sci 2004;45: E-abstract 2929.
53. Parel J-M, Stoiber J, Fernandez V, Acosta AC, Lamar PD, Dubovy S, et al. Ocular and orbital biocompatibility of a novel implant material (SIBS): a preliminary study, in preparation.
54. A newly designed glaucoma drainage implant made of poly(styrene-b-isobutylene-b-styrene) biocompatibility and function in normal rabbit eyes10.1001/archopht.124.12.1742 ↗
55. Pinchuk L, Fantes F, Zhou Y, Martin JB, Parel J-M. The BPEI-innfocus glaucoma drainage implant—the MIDI: concept, physics and pressure control. Invest Ophthalmol Vis Sci 2006;47: E-Abstract 36.
56. Acosta AC, Espana EM, Orozco M, Yamamoto H, Pinchuk L, Dubovy S, et al. A novel glaucoma implant: a comparative SIBS vs PDMS study in normal rabbits. Invest Ophthalmol Vis Sci 2006;47: E-Abstract 3545.
57. Fantes F, Acosta AC, Carraway J, Siddiq F, Pinchuk L, Weber BA, et al. An independent GLP evaluation of a new glaucoma drain, the MIDI. Invest Ophthalmol Vis Sci 2006;47: E-Abstract 3547.
58. Orozco M, Acosta AC, Espana EM, Davis S, Weber BA, Pinchuk L, et al. New styrene-b-isobutylene-b-styrene (SIBS) glaucoma drainage implant. Ophthalmic technologies XVI. Proceedings of the SPIE, vol. 6138, 2006, p. 177–84.10.1117/12.652297 ↗
59. Aly M, Yamamoto H, Espana EM, Orozco MA, Aguilar M, Arrieta E, et al. A novel material for scleral buckle procedure: an experimental comparative pilot study, in preparation.
60. Surgical correction of severe myopia with an angle-supported phakic intraocular lens10.1016/S0886-3350(00)00543-5 ↗
61. A novel trileaflet synthetic heart valve
62. Yin W, Gallocher S, Pinchuk L, Schoephoerster R, Jesty J, Bluestein D. Comparative measurements of flow induced platelet activation in a trileaflet polymeric valve and a St. Jude medical bileaflet mechanical heart valve. Transactions of the Society For Biomaterials, Philadelphia, October, 2004.
63. A novel polymer with potential use in a trileaflet heart valve10.1002/jbm.b.30546 ↗
64. Flow induced platelet activation in a st. jude mechanical heart valve, a trileaflet polymeric heart valve and a st jude tissue valve10.1111/j.1525-1594.2005.29109.x ↗
65. Wang Q, Gallocher SL, Mathison M., Kato Y, Pinchuk L, Schoephoerster RT. In vivo pre-clinical evaluation of a novel polymeric aortic valve. In: Proceedings of the 2006 BMES annual fall meeting, October 11–14, Chicago, IL, 2006.
66. Gallocher S, Wang Q, Mathison M, Kato Y, Pinchuk L, Schoephoerster RT. Feasibility analysis of the safety and durability of a polymer trileaflet heart valve. In: Proceedings of the 2006 summer Bioengineering conference, June 21–25, Amelia Island plantation, Amelia Island, FL, 2006.