journal article·2012-04

Endothelialization and patency of RGD-functionalized vascular grafts in a rabbit carotid artery model

Wenting Zheng, Zhihong Wang, Lijie Song, Qiang Zhao, Jun Zhang, Dong Li, Shufang Wang, Jihong Han, Xi-Long Zheng, Zhimou Yang, Deling Kong

Biomaterials· Volume 33· Issue 10
Publisher page

Abstract

To address the growing demand of small-diameter vascular grafts for cardiovascular disease, it is necessary to develop substitutes with bio-functionalities, such as anticoagulation, rapid endothelialization, and smooth muscle regeneration. In this study, the small-diameter tubular grafts (2.2 mm) were fabricated by electrospinning of biodegradable polymer polycaprolactone (PCL) followed by functional surface coating with an arginine-glycine-aspartic acid (RGD)-containing molecule. The healing characteristics of the grafts were evaluated by implanting them in rabbit carotid arteries for 2 and 4 weeks. Results showed that at both time points, all 10 of the RGD-modified PCL grafts (PCL-RGD) were patent, whereas 4 of the 10 non-modified PCL grafts were occluded due to thrombus formation. Scanning electron microscopy (SEM) data showed abundant platelets adhering on the surface of the midportion of the PCL grafts. In contrast, only few platelets were observed on the PCL-RGD surface, suggesting that RGD modification significantly improved the hemocompatibility of the PCL grafts. Histological analysis demonstrated enhanced cell infiltration and homogeneous distribution within the PCL-RGD grafts in comparison with the PCL grafts. Furthermore, immunofluorescence staining also showed a 3-fold increase of endothelial coverage of the PCL-RGD grafts than that of PCL grafts at those two time points. After 4-week implantation, 65.3 ± 7.6% of the surface area of the PCL-RGD grafts was covered by smooth muscle cell layer, which is almost 23% more than that on the PCL grafts. The present study indicates that RGD-modified PCL grafts exhibit an improved remodeling and integration capability in revascularization.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Electrospun Nanofibers in Biomedical Applications · Tissue Engineering and Regenerative Medicine · Polymer Surface Interaction Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (47)

Show source-provided references
1. Conduit options in coronary artery bypass surgery10.1378/chest.108.4.1150 ↗
2. Prosthetic vascular grafts: wrong models, wrong questions and no healing10.1016/j.biomaterials.2007.07.017 ↗
3. In vivo regeneration of small-diameter (2 mm) arteries using a polymer scaffold10.1096/fj.05-4802fje ↗
4. Long-term patency of small-diameter vascular graft made from fibroin, a silk-based biodegradable material10.1016/j.jvs.2009.09.005 ↗
5. A small diameter, fibrous vascular conduit generated from a poly (ester urethane) urea and phospholipid polymer blend10.1016/j.biomaterials.2009.01.013 ↗
6. Gel spinning of silk tubes for tissue engineering10.1016/j.biomaterials.2008.08.025 ↗
7. Fabrication and properties of the electrospun polylactide/silk fibroin-gelatin composite tubular scaffold10.1021/bm900416b ↗
8. Artificial blood vessel: the holy grail of peripheral vascular surgery10.1016/j.jvs.2004.12.026 ↗
9. Growing a living blood vessel: insights for the second hundred years10.1016/j.biomaterials.2007.07.048 ↗
10. Complexity in biomaterials for tissue engineering10.1038/nmat2441 ↗
11. Antithrombogenic modification of small-diameter microfibrous vascular grafts10.1161/ATVBAHA.110.208348 ↗
12. The return of a forgotten polymer-polycaprolactone in the 21st century10.1016/j.progpolymsci.2010.04.002 ↗
13. Degradation and healing characteristics of small-diameter poly(ɛ-caprolactone) vascular grafts in the rat systemic arterial circulation10.1161/CIRCULATIONAHA.108.795732 ↗
14. A three-layered electrospun matrix to mimic native arterial architecture using polycaprolactone, elastin, and collagen: a preliminary study10.1016/j.actbio.2009.12.029 ↗
15. Bilayered scaffold for engineering cellularized blood vessel10.1016/j.biomaterials.2010.02.002 ↗
16. Surface functionalization of polycaprolactone films via surface-initiated atom transfer radical polymerization for covalently coupling cell-adhesive biomolecules10.1016/j.biomaterials.2010.01.032 ↗
17. Biofunctionalization of biomaterials for accelerated in situ endothelialization: a review10.1021/bm800681k ↗
18. Induction of EPC homing on biofunctionalized vascular grafts for rapid in vivo self-endothelialization-a review of current strategies10.1016/j.biotechadv.2009.10.005 ↗
19. RGD-Functionalized polymer brushes as substrates for the integrin specific adhesion of human umbilical vein endothelial cells10.1016/j.biomaterials.2007.02.006 ↗
20. The role of short synthetic adhesion peptides in regenerative medicine; the debate10.1016/j.biomaterials.2011.02.025 ↗
21. Direct grafting of RGD-motif-containing peptide on the surface of polycaprolactone films10.1163/156856206776986288 ↗
22. Enhancing growth human endothelial cells on Arg-Gly-Asp (RGD) embedded poly (ɛ-caprolactone) (PCL) surface with nanometer scale of surface disturbance10.1002/jbm.a.30225 ↗
23. A hybrid biomimetic scaffold composed of electrospun polycaprolactone nanofibers and self-assembled peptide amphiphile nanofibers10.1088/1758-5082/1/2/025001 ↗
24. Highly stable surface modifications of poly(ɛ-caprolactone) (PCL) films by molecular self-assembly to promote cells adhesion and proliferation10.1039/c1cc11564b ↗
25. Immobilization of anti-CD31 antibody on electrospun poly(ɛ-caprolactone) scaffolds through hydrophobins for specific adhesion of endothelial cells10.1016/j.colsurfb.2010.10.042 ↗
26. Implantation of decellularized small-caliber vascular xenografts with and without surface heparin treatment10.1111/j.1525-1594.2007.00348.x ↗
27. Surface modification of polycaprolactone membrane via aminolysis and biomacromolecule immobilization for promoting cytocompatibility of human endothelial cells10.1021/bm020074y ↗
28. Branched peptide-amphiphiles as self-assembling coatings for tissue engineering scaffolds10.1002/jbm.a.30718 ↗
29. Bioactive stent surface coating that promotes endothelialization while preventing platelet adhesion10.1021/bm101212k ↗
30. RGD modified polymers: biomaterials for stimulated cell adhesion and beyond10.1016/S0142-9612(03)00343-0 ↗
31. Endothelial cells in physiology and in the pathophysiology of vascular disorders
32. Development of a hybrid cardiovascular graft using a tissue engineering approach10.1096/fj.01-0826com ↗
33. Improving endothelial cell retention for single stage seeding of prosthetic grafts: use of polymer sequences of arginine-glycine-aspartate10.1053/ejvs.2002.1854 ↗
34. Regulation of endothelial cell function by GRGDSP peptide grafted on interpenetrating polymers10.1002/jbm.a.31320 ↗
35. New perspectives in cell adhesion: RGD and integrins10.1126/science.2821619 ↗
36. Endothelial cells adhere to the RGD domain and the fibrinogen-like terminal knob of tenascin10.1242/jcs.106.1.389 ↗
37. Enhanced dermal wound neovascularization by targeted delivery of endothelial progenitor cells using an RGD-g-PLLA scaffold10.1016/j.biomaterials.2009.03.053 ↗
38. Endothelial progenitor cells: characterization and role in vascular biology10.1161/01.RES.0000137877.89448.78 ↗
39. A novel drug-eluting stent coated with an integrin-binding cyclic Arg-Gly-Asp peptide inhibits neointimal hyperplasia by recruiting endothelial progenitor cells10.1016/j.jacc.2005.11.081 ↗
40. Biomimetic control of vascular smooth muscle cell morphology and phenotype for functional tissue-engineered small-diameter blood vessels10.1002/jbm.a.32318 ↗
41. The in vivo stability of electrospun polycaprolactone-collagen scaffolds in vascular reconstruction10.1016/j.biomaterials.2008.10.006 ↗
42. Tissue-engineered vascular grafts transform into mature blood vessels via an inflammation-mediated process of vascular remodeling10.1073/pnas.0911465107 ↗
43. Diverse contribution of bone marrow cells to neointimal hyperplasia after mechanical vascular injuries10.1161/01.RES.0000096651.13001.B4 ↗
44. Smooth muscle cells in transplant atherosclerotic lesions are originated from recipients, but not bone marrow progenitor cells10.1161/01.CIR.0000031333.86845.DD ↗
45. The origin of post-injury neointimal cells in the rat balloon injury model10.1093/cvr/cvn265 ↗
46. Flanking recipient vasculature, not circulating progenitor cells, contributes to endothelium and smooth muscle in murine allograft vasculopathy10.1161/ATVBAHA.110.221184 ↗
47. The use of animal models in developing the discipline of cardiovascular tissue engineering: a review10.1016/S0142-9612(03)00522-2 ↗