journal article·2008-02

Prosthetic heart valves: Catering for the few

Peter Zilla, Johan Brink, Paul Human, Deon Bezuidenhout

Biomaterials· Volume 29· Issue 4
Publisher page

Abstract

Prosthetic heart valves epitomize both the triumphant advance of cardiac surgery in its early days and its stagnation into a retrospective, exclusive first world discipline of late. Fifty-two years after the first diseased heart valve was replaced in a patient, prostheses largely represent the concepts of the 1960s with many of their design-inherent complications. While the sophisticated medical systems of the developed world may be able to cope with sub-optimal replacements, these valves are poorly suited to the developing world (where the overwhelming majority of potential valve recipients reside), due to differences in age profiles and socio-economic circumstances. Therefore, it is the latter group which suffered most from the sluggish pace of developments. While it previously took less than 7 years for mechanical heart valves to develop from the first commercially available ball-in-cage valve to the tilting pyrolytic-carbon disc valve, and another 10 years to arrive at the all-carbon bi-leaflet design, only small incremental improvements have been achieved since 1977. Similarly, bioprosthetic valves saw their last major break-through development in the late 1960s when formalin fixation was replaced by glutaraldehyde cross linking. Since then, poorly understood so-called 'anti-calcification' treatments were added and the homograft concept rediscovered under the catch-phrase 'stentless'. Still, tissue valves continue to degenerate fast in younger patients, making them unsuitable for developing countries. Yet, catheter-delivered prostheses almost exclusively use bioprosthetic tissue, thereby reducing one of the most promising developments for patients of the developing world into a fringe product for the few first world recipients. With tissue-engineered valves aiming at the narrow niche of congenital malformations and synthetic flexible leaflet valves being in their fifth decade of low-key development, heart valve prostheses seem to be destined to remain an unsatisfying and exclusive first world solution for a long time to come.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Cardiac Valve Diseases and Treatments · Infective Endocarditis Diagnosis and Management · Aortic Disease and Treatment Approaches

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (100+)

Show source-provided references
1. Partial and complete prostheses in aortic insufficiency10.1016/S0022-5223(19)32572-3 ↗
2. Complete replacement of the mitral valve. Successful clinical application of a flexible polyurethane prosthesis10.1016/S0022-5223(19)32638-8 ↗
3. Heterograft aortic valve translantation for valve disease10.5694/j.1326-5377.1966.tb73530.x ↗
4. Biological factors affecting long-term results of valvular heterografts10.1016/S0022-5223(19)42561-0 ↗
5. Mitral replacement: clinical experience with a ball-valve prosthesis10.1097/00000658-196110000-00017 ↗
6. Aortic valve replacement with the Bjork-Shiley tilting disc valve prosthesis10.1136/hrt.33.Suppl.42 ↗
7. A new cardiac prosthesis: the St. Jude Medical cardiac valve: in vivo results10.1161/01.CIR.60.2.48 ↗
8. The biomechanical effects of fatigue on the porcine bioprosthetic heart valve
9. Analysis of prosthetic cardiac devices: a guide for the practising pathologist10.1136/jcp.2004.020271 ↗
10. Epidemiology of rheumatic heart disease in black shcoolchildren of Soweto, Johannesburg10.1136/bmj.3.5981.474 ↗
11. International cardiac surgery: a global perspective10.1053/stcs.2002.0140298 ↗
12. Long-term relative survival after primary heart valve replacement10.1016/S1010-7940(96)01025-1 ↗
13. Medtronic Hall valve replacement in a third-world population group. A review of the performance of 1000 prostheses10.1016/S0022-5223(19)35663-6 ↗
14. St. Jude Medical valve replacement. An evaluation of valve performance10.1016/S0022-5223(19)35788-5 ↗
15. International cardiac surgery10.1053/stcs.2002.35294 ↗
16. Actuarial versus actual risk of porcine structural valve deterioration10.1016/S0022-5223(94)70298-5 ↗
17. Edwards Lifesciences OEW, Irvine, CA 92614-5686, USA. Clinical Communique, Carpentier-Edwards Perimount, Pericardial Bioprosthesis, Model 2700. Edwards Lifesciences LLC.
18. An “actual” problem: another issue of apples and oranges10.1016/j.jtcvs.2005.11.013 ↗
19. Could it happen again? The Bjork-Shiley convexo-concave heart valve story10.1161/CIRCULATIONAHA.105.540518 ↗
20. Strut fracture mechanisms of the Bjork-Shiley convexo-concave heart valve
21. Twenty-five-year experience with the Bjork-Shiley convexoconcave heart valve: a continuing clinical concern10.1161/CIRCULATIONAHA.104.511659 ↗
22. Leaflet escape in a revised Edwards-Duromedics mitral prosthesis
23. Mitral valve replacement with the Smeloff-Cutter prosthesis. Experience with 154 patients and comparison with results of replacement with a Starr-Edwards prosthesis10.1016/S0022-5223(19)41589-4 ↗
24. Duromedics original prosthesis: what do we really know about diagnosis and mechanism of leaflet escape?
25. Mechanical heart valve cavitation10.1586/17434440.1.1.95 ↗
26. Leaflet fracture in Edwards-Duromedics bileaflet valves10.1016/S0022-5223(19)35130-X ↗
27. Manufacturing characteristics associated with strut fracture in Bjork-Shiley 60 degrees convexo-concave heart valves
28. Actuarial comparison of Hancock porcine and prosthetic disc valves for isolated mitral valve replacement
29. Ligation of the left atrial appendage using an automatic surgical stapler10.1016/S0003-4975(10)64728-5 ↗
30. Pulsatile flow experiments on heart valve prostheses10.1007/BF02442377 ↗
31. The St. Jude Medical prosthesis. A thirteen-year experience10.1016/S0022-5223(94)70004-4 ↗
32. The Medtronic-Hall cardiac valve: 7 1/2 years’ clinical experience10.1016/S0003-4975(10)64598-5 ↗
33. Seven and one-half years’ experience with the Medtronic-Hall valve10.1016/S0735-1097(85)80234-5 ↗
34. Thrombosed Bjork-Shiley mitral prostheses10.1161/01.CIR.61.1.169 ↗
35. Survival despite almost complete occlusion by chronic thrombosis of a Bjork-Shiley mitral prosthesis
36. Mitral replacement: clinical experience with a ball-valve prosthesis. Twenty-five years later10.1097/00000658-198509000-00016 ↗
37. Long-term performance of heart valve prostheses10.1053/cd.2000.v25.a103682 ↗
38. Ten to fifteen year reassessment of the performance characteristics of the Starr-Edwards Model 6120 mitral valve prosthesis10.1016/S0022-5223(19)38894-4 ↗
39. Twenty years’ experience with the Model 6120 Starr-Edwards valve in the mitral position10.1016/S0022-5223(19)36250-6 ↗
40. Thirty-year results of Starr-Edwards prostheses in the aortic and mitral position10.1016/S0003-4975(96)00945-9 ↗
41. Mitral valve replacement10.1016/0011-3840(93)90015-9 ↗
42. A six-year study of the Omniscience valve in four Canadian centers10.1016/S0003-4975(10)60199-3 ↗
43. Long-term clinical experience with the Omnicarbon prosthetic valve10.1016/S0003-4975(99)00557-3 ↗
44. Eight years’ experience with the Medtronic-Hall valve prosthesis10.1016/0003-4975(90)90489-S ↗
45. Anticoagulation variability between centres: implications for comparative prosthetic valve assessment10.1016/S1010-7940(88)80002-2 ↗
46. Comparative clinical results with Omniscience (STM1), Medtronic-Hall, and Bjork-Shiley convexo-concave (70 degrees) prostheses in mitral valve replacement10.1016/S0022-5223(19)36076-3 ↗
47. Mechanical cardiac valvular prostheses10.1016/0003-4975(91)91453-3 ↗
48. In vitro hydrodynamic comparison of mitral valve prostheses at high flow rates10.1016/S0022-5223(19)39553-4 ↗
49. An appreciation of the new St. Jude valvular prosthesis10.1016/S0022-5223(19)37627-5 ↗
50. Ten years’ experience with the St. Jude Medical valve prosthesis10.1016/0003-4975(89)90014-3 ↗
51. The St. Jude valve: analysis of thromboembolism, warfarin-related hemorrhage, and survival10.1016/0002-8703(87)90508-4 ↗
52. Long-term performance of the St. Jude Medical valve: low incidence of thromboembolism and hemorrhagic complications with modest doses of warfarin
53. Clinical experience with the CarboMedics valve: early results with a new bileaflet mechanical prosthesis10.1016/S0022-5223(96)70178-2 ↗
54. Long-term results of valve replacement with the St. Jude Medical valve10.1016/S0022-5223(94)70143-1 ↗
55. Four-year experience with the CarboMedics valve: the North American experience. North American team of clinical investigators for the CarboMedics prosthetic heart valve10.1016/0003-4975(94)90719-6 ↗
56. An international experience with the CarboMedics prosthetic heart valve
57. The initial United States experience with the ATS mechanical cardiac valve prosthesis
58. Valve replacement with the ATS open pivot bileaflet prosthesis10.1016/S1010-7940(96)80382-4 ↗
59. Early clinical experience with the On-X prosthetic heart valve
60. Intracranial traumatic and non-traumatic haemorrhagic complications of warfarin treatment10.1111/j.1600-0404.1995.tb00436.x ↗
61. Lower intensity anticoagulation therapy results in lower complication rates with the St. Jude Medical prosthesis10.1016/S0022-5223(94)70391-4 ↗
62. Hematological complications with the St. Jude valve and reduced-dose Coumadin10.1016/0003-4975(89)90089-1 ↗
63. Clinical experience with the Omnicarbon prosthetic heart valve10.1016/S0022-5223(19)33862-0 ↗
64. Six years’ experience with the Omnicarbon valve prosthesis10.1177/096721099300100525 ↗
65. Clinical evaluation of the Omniscience cardiac valve prosthesis. Follow-up of up to 6 years10.1016/S0022-5223(19)35026-3 ↗
66. Twenty years’ experience with the Medtronic Hall valve10.1067/mtc.2001.113754 ↗
67. Mid-term follow-up after heart valve replacement with CarboMedics bileaflet prostheses10.1016/S0022-5223(19)33993-5 ↗
68. Development of the Chitra tilting disc heart valve prosthesis
69. Chitra heart valve: results of a multicenter clinical study
70. Clinical course after mitral valve replacement
71. Multivariate analysis for operative mortality in obstructive prosthetic valve dysfunction due to pannus and thrombus formation10.1536/ihj.47.237 ↗
72. Obstruction of mechanical mitral prostheses: analysis of pathologic findings10.1016/S0003-4975(96)01391-4 ↗
73. Reoperation for prosthetic aortic valve obstruction in the era of echocardiography: trends in diagnostic testing and comparison with surgical findings10.1016/S0735-1097(00)01113-X ↗
74. Obstruction of St. Jude Medical valves in the aortic position: histology and immunohistochemistry of pannus10.1016/S0022-5223(03)00702-5 ↗
75. Functional versus quantitative comparison of IL-1 beta from monocytes/macrophages on biomedical polymers [published erratum appears in J Biomed Mater Res 1994 Jan;28(1);137]10.1002/jbm.820270910 ↗
76. Advanced technologies for cardiac valvular replacement, transcatheter innovations and reconstructive surgery
77. A comparison of mechanical valve performance in a poorly anticoagulated community10.1111/j.0886-0440.2004.04084.x ↗
78. Discontinuing oral anticoagulation therapy
79. Patterns of failure in Ionescu-Shiley bovine pericardial bioprosthetic valves10.1016/S0022-5223(19)37054-0 ↗
80. Low-profile porcine bioprosthesis (Liotta): pathologic findings and mode of failure in the long-term
81. Refinement of the alpha aminooleic acid bioprosthetic valve anticalcification technique10.1016/S0003-4975(97)00118-5 ↗
82. Calcification resistance with aluminum-ethanol treated porcine aortic valve bioprostheses in juvenile sheep10.1016/S0003-4975(02)04489-2 ↗
83. Tannic acid treatment enhances biostability and reduces calcification of glutaraldehyde fixed aortic wall10.1016/j.biomaterials.2004.04.034 ↗
84. Toronto porcine stentless valve and the need for something more10.1016/j.carpath.2005.10.005 ↗
85. Three-dimensional in vivo characterization of calcification in native valves and in Freestyle versus homograft aortic valves10.1016/j.jtcvs.2005.02.056 ↗
86. Structural changes of glutaraldehyde-treated porcine bioprosthetic valves
87. Anatomic analysis of removed prosthetic heart valves: causes of failure of 33 mechanical valves and 58 bioprostheses, 1980 to 198310.1016/S0046-8177(85)80103-9 ↗
88. Characterization of the immune response to valve bioprostheses and its role in primary tissue failure10.1016/S0003-4975(01)02492-4 ↗
89. Chemically modified collagen: a natural biomaterial for tissue replacement10.1002/jbm.820210606 ↗
90. Immunogenicity of glutaraldehyde-tanned bovine pericardium10.1016/S0022-5223(20)31465-3 ↗
91. The possible role of immune responses in bioprosthetic heart valve failure
92. Does glutaraldehyde induce calcification of bioprosthetic tissues?10.1016/S0003-4975(98)01098-4 ↗
93. High glutaraldehyde concentrations reduce rather than increase the calcification of aortic wall tissue
94. High glutaraldehyde concentrations mitigate bioprosthetic root calcification in the sheep model10.1016/S0003-4975(00)02011-7 ↗
95. Graft-specific antibody implicated in calcification of valve bioprosthetic tissue
96. Inflammatory and immune processes: the neglected villain of bioprosthetic degeneration?
97. Structural changes in glutaraldehyde-treated porcine heterografts used as substitute cardiac valves. Transmission and scanning electron microscopic observations in 12 patients10.1016/0002-9149(78)90873-1 ↗
98. Pathologic evaluation of a unileaflet pericardial bioprosthesis after implantation as tricuspid and mitral valve replacements in sheep
99. Stentless bioprosthetic heart valve research: sheep versus primate model10.1016/S0003-4975(01)02502-4 ↗
100. Comparative study of primary tissue valve failure between Ionescu-Shiley pericardial and Hancock porcine valves in the aortic position10.1016/0002-9149(86)90972-0 ↗