Inflammatory responses to orthopaedic biomaterials in the murine air pouch
Source abstract
Abstract
An in vivo model of the inflammatory response to orthopaedic biomaterials was used to examine cellular and cytokine responses to polymer particles of ultra high molecular weight polyethylene (UHMWPE) and polymethylmethacrylate (PMMA), and metal particles of cobalt-chrome (Co-Cr) and titanium alloy (Ti-6Al-4V). Responses were determined separately and in combinations, to examine interactions between different forms of biomaterials. Murine air pouches were injected with particle suspensions, and reactions evaluated using histological, immunological, and molecular techniques. All particulate biomaterials caused significant increases in membrane thickness compared with control (saline) air pouches, with the highest reaction seen in response to Ti-6Al-4V particles. A synergistic increase in membrane thickness was observed when PMMA was combined with UHMWPE, suggesting that multiple biomaterial stimuli markedly increase the inflammatory reaction. Cellular analysis indicated that all particles increased the absolute number and the percentage of macrophages in the membrane over the control level, with the most pronounced increase due to individual biomaterial occurring with UHMWPE particles. Cytokine analysis revealed that biomaterials provoked a strong IL-1 response. Ti-6Al-4V stimulated the highest IL-6 gene transcription and the lowest IL-1 gene transcription. The data suggest that synergism in the inflammatory response to biomaterials may be important in adverse responses to orthopaedic wear debris.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (34)
Show source-provided references
1. The immune response to implant materials in humans10.1097/00003086-199605000-00008 ↗
2. Cellular mediators secreted by interfacial membranes obtained at revision total hip arthroplasty10.1016/S0883-5403(05)80152-4 ↗
3. Prosthetic synovitis
4. Aggressive granulomatous lesions associated with hip arthroplasty. Immunopathological studies10.2106/00004623-199072020-00014 ↗
5. Eftekhar NS, Doty SB, Johnston AD, Parisien MV. Prosthetic synovitis. Hip 1985;169–83.
6. In vivo inflammatory response to polymethylmethacrylate particulate debris10.1002/jor.1100120111 ↗
7. Nagase M, Udagawa E, Schumacher HR, Baker DG. Prolonged inflammatory reactions induced by ceramic powders in the rat air pouch model. Nippon Seikeigeka Gakkai Zasshi—J Jpn Orthop Assoc 1990;64:602–11.
8. Increased inflammatory reactivity in newly formed lining tissue10.1002/path.1711410406 ↗
9. The role of adherent endotoxin in stimulation of osteoclast differentiation by orthopaedic wear particles
10. Cellular proliferation and cytokine responses to polymethylmethacrylate (PMMA) following joint replacement10.1007/BF01782811 ↗
11. T cells infiltrating the skin of Tsk2 scleroderma-like mice exhibit T cell receptor bias10.3109/08916939809008039 ↗
12. The influence of silicone implantation on type II collagen-induced arthritis in mice10.1002/art.1780400611 ↗
13. Prolonged inflammatory reactions induced by artificial ceramics in the rat air pouch model
14. A model of cellular responses in aseptic loosening
15. Synergistic inflammatory responses to metallic and polymeric particles in the murine air pouch model of aseptic loosening
16. Tissue reactions to cemented hip sockets. Histologic and morphometric autopsy study of 25 acetabula10.3109/17453679508994628 ↗
17. Histological features of the interface membrane of failed isoelastic cementless prostheses10.1007/BF00182653 ↗
18. Tissue reaction to implanted biomaterials10.1016/0022-3913(85)90023-X ↗
19. In vitro studies on the role of titanium in aseptic loosening10.1097/00003086-199609000-00032 ↗
20. Agins HJ, Alcock NW, Bansal M, Salvati EA, Wilson Jr. PD, Pellicci PM, Bullough PG. Metallic wear in failed titanium-alloy total hip replacements. A histological and quantitative analysis. J Bone Jt Surg—Am Vol 1988;70:347–56.10.2106/00004623-198870030-00005 ↗
21. Evolution of aggressive granulomatous periprosthetic lesions in cemented hip arthroplasties10.1097/00003086-199403000-00020 ↗
22. Lombardi Jr. AV, Mallory TH, Vaughn BK, Drouillard P. Aseptic loosening in total hip arthroplasty secondary to osteolysis induced by wear debris from titanium-alloy modular femoral heads. J Bone Jt Surg—Am Vol 1989;71:1337–42.10.2106/00004623-198971090-00009 ↗
23. Metal wear and tissue response in failed titanium alloy total hip replacements10.1302/0301-620X.73B4.2071635 ↗
24. The histological effects of the implantation of different sizes of polyethylene particles in the rabbit tibia10.1002/jbm.820240408 ↗
25. Enhancement of inflammatory reactions in a nonimmunological air pouch model in rats
26. Lymphocyte kinetics in a murine model of chronic inflammation10.1007/BF01972853 ↗
27. Interleukin-1 production by activated macrophages surrounding loosened orthopaedic implants10.1093/rheumatology/33.4.309 ↗
28. Analysis of cell types and mediator production from tissues around loosening joint implants10.1093/rheumatology/34.12.1127 ↗
29. Production of cytokines around loosened cemented acetabular components. Analysis with immunohistochemical techniques and in situ hybridization10.2106/00004623-199306000-00007 ↗
30. Titanium wear debris in failed cemented total hip arthroplasty. An analysis of 71 cases10.1016/0883-5403(92)90056-V ↗
31. Drug inhibition of the macrophage response to metal wear particles in vitro10.1097/00003086-199602000-00045 ↗
32. Macrophage ferritin and iron deposition in the rat air pouch model of inflammatory synovitis10.1136/ard.46.4.334 ↗
33. Variation in cytokines induced by particles from different prosthetic materials10.1097/00003086-199807000-00026 ↗
34. Cytokine and prostaglandin E2 release from leukocytes in response to metal ions derived from different prosthetic materials10.1111/j.1525-1594.1999.06343.x ↗