Mechanical responses of a compliant electrospun poly(l-lactide-co-ε-caprolactone) small-diameter vascular graft
Source abstract
Abstract
To design a "mechano-active" small-diameter artificial vascular graft, a tubular scaffold made of elastomeric poly(L-lactide-co-epsilon-caprolactone) fabrics at different wall thicknesses was fabricated using an electrospinning (ELSP) technique. The wall thickness of the fabricated tube (inner diameter; approximately 2.3-2.5 mm and wall thickness; 50-340 microm) increased proportionally with ELSP time. The wall thickness dependence of mechanical responses including intraluminal pressure-induced inflation was determined under static and dynamic flow conditions. From the compliance-related parameters (stiffness parameter and diameter compliance) measured under static condition, the smaller the wall thickness, the more compliant the tube. Under dynamic flow condition (1 Hz, maximal/minimal pressure of 90 mmHg/45 mmHg) produced by a custom-designed arterial circulatory system, strain, defined as the relative increase in diameter per pulse, increased with the decrease in wall thickness, which approached that of a native artery. Thus, a mechano-active scaffold that pulsates synchronously by responding to pulsatile flow was prepared using elastomeric PLCL as a base material and an ELSP technique.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Electrospun Nanofibers in Biomedical Applications · Tissue Engineering and Regenerative Medicine · Polymer Nanocomposite Synthesis and Irradiation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (32)
Show source-provided references
1. Small-diameter vascular graft prostheses: current status10.1076/apab.106.2.100.4384 ↗
2. Biomaterials in the development and future of vascular grafts10.1067/mva.2003.88 ↗
3. Recent progress of vascular graft engineering in Japan10.1111/j.1525-1594.2004.07324.x ↗
4. Low compliance and arterial graft occlusion
5. Matched elastic properties and successful arterial grafting10.1001/archsurg.1980.01380100018004 ↗
6. Compliance: a continuing problem with vascular grafts
7. Effect of compliance mismatch on vascular graft patency10.1016/0741-5214(87)90148-0 ↗
8. Effects of a vascular graft/natural artery compliance mismatch on pulsatile flow10.1016/0021-9290(92)90027-X ↗
9. Compliance and diameter mismatch affect the wall shear rate distribution near an end-to-end anastomosis10.1016/0021-9290(95)00028-3 ↗
10. Long-term biologic fate of neoarteries regenerated in microporous, compliant, biodegradable, small-caliber vascular grafts in rats
11. Elastic properties and strength of a novel small-diameter, compliant polyurethane vascular graft
12. Porous polyurethane vascular prostheses with variable compliances10.1002/jbm.820261108 ↗
13. Novel compliant and tissue-permeable microporous polyurethane vascular prosthesis fabricated using an excimer laser ablation technique10.1002/(SICI)1097-4636(199605)31:1<27::AID-JBM4>3.0.CO;2-S ↗
14. Small-diameter compliant arterial graft prosthesis: design concept of coaxial double tubular graft and its fabrication10.1002/1097-4636(20010605)55:3<266::AID-JBM1014>3.0.CO;2-C ↗
15. Formhals A. Process and apparatus for preparing artificial threads. US patent no. 1,975,504, 1934.
16. Nanometre diameter fibres of polymer, produced by electrospinning10.1088/0957-4484/7/3/009 ↗
17. Electrospun nanofibrous structure: a novel scaffold for tissue engineering10.1002/jbm.10167 ↗
18. Electrospun P(LLA-CL) nanofiber: a biomimetic extracellular matrix for smooth muscle cells and endothelial cell proliferation10.1016/j.biomaterials.2003.08.042 ↗
19. Aligned biodegradable nanofibrous structure: a potential scaffold for blood vessel engineering10.1016/S0142-9612(03)00593-3 ↗
20. Electrospun nano- to microfiber fabrics made of biodegradable copolyesters: structural characteristics, mechanical properties and cell adhesion potential10.1016/j.biomaterials.2004.10.007 ↗
21. Co-electrospun nanofiber fabrics of poly(l-lactide-co-ε-caprolactone) with type I collagen or heparin10.1021/bm050086u ↗
22. Mesoscopic spatial designs of nano- and microfiber meshes for tissue-engineering matrix and scaffold based on newly devised multilayering and mixing electrospinning techniques10.1016/j.biomaterials.2004.01.063 ↗
23. Mechano-active scaffold design of small-diameter artificial graft made of electrospun segmented polyurethane fabrics10.1002/jbm.a.30260 ↗
24. Stiffness and elastic behavior of human intracranial and extracranial arteries10.1016/0021-9290(80)90191-8 ↗
25. Chandran · 1992
26. Manufacture of elastic biodegradable PLCL scaffolds for mechano-active vascular tissue engineering10.1163/156856204323046906 ↗
27. Morphology of elastic poly(l-lactide-co-ε-caprolactone) copolymers and in vitro and in vivo degradation behavior of their scaffolds10.1021/bm049921i ↗
28. In vivo biocompatibility and degradation behavior of elastic poly(l-lactide-co-ε-caprolactone) scaffolds10.1016/j.biomaterials.2004.01.057 ↗
29. An elastomeric vascular prosthesis
30. The elastic properties of a polyurethane arterial prosthesis10.1016/0021-9290(84)90091-5 ↗
31. Compliant design of artificial graft: compliance determination by new digital X-ray imaging system-based method10.1002/jbm.10055 ↗
32. Adaptive regulation of wall shear stress optimizing vascular tree function10.1016/S0092-8240(84)80038-5 ↗