journal article·2002-06

Antithrombogenic investigation of surface energy and optical bandgap and hemocompatibility mechanism of Ti(Ta+5)O2 thin films

J.Y Chen, Y.X Leng, X.B Tian, L.P Wang, N Huang, P.K Chu, P Yang

Biomaterials· Volume 23· Issue 12
Publisher page

Abstract

Recent improvements in the antithrombogenic properties of blood contacting biomaterials permit a hybrid design of layers for biomedical applications such as artificial heart valves and stents. Using magnetron sputtering and thermal oxidation, titanium oxide thin films containing tantalum. Ti(Ta(+5))O2, are fabricated to meet the challenge of enhanced hemocompatibility. The blood compatibility is evaluated in vitro by clotting time and platelet adhesion measurement, and in vivo experiments are also conducted. The Ti(Ta(+5))O2 films exhibit attractive blood compatibility exceeding that of low isotropic pyrolytic carbon. Physical properties such as surface energy and semiconductivity are found to play important roles. Our calculated results reveal that the smaller surface force gamma(s) of the film and the smaller blood film interfacial tension gamma(c,blood) are partially responsible for the enhancement of the blood compatibility. Based on the optical bandgap model, the film possesses better hemocompatibility because its optical bandgap of 3.2 eV is wider than that of fibrinogen having a bandgap of 1.8 eV. These factors result in thinner protein layers on the film surface, less protein denaturing, and overall excellent antithrombogenic properties.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Polymer Surface Interaction Studies · Bone Tissue Engineering Materials · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (21)

Show source-provided references
1. Development of a ceramic artificial heart valve10.1177/088532828900400103 ↗
2. Ex vivo leucocyte adhesion and protein adsorption on TiN10.1016/0142-9612(93)90070-I ↗
4. Artificial heart valves10.1111/j.1525-1594.1990.tb02967.x ↗
5. Blood compatibility of diamond-like carbon coating10.1016/0142-9612(91)90129-X ↗
6. Titanium–protein interaction10.1177/088532829100600107 ↗
7. Ebert R, Schaldach M. Ceramic as material for cardiovascular device. World Congress on Medical Physics and Biomedical Engineering, Hamburg, vol. 3, 1982. p. 07.
8. Blood compatibility of amorphous titanium oxide films synthesized by ion beam enhanced deposition10.1016/S0142-9612(98)00212-9 ↗
9. A new method for evaluation of antithrombogenicity of materials10.1002/jbm.820060305 ↗
10. Andreas von FR. Handbook of biomaterials evaluation: scientific, technical, and clinical testing. Ann Arbor, MI: Edwards, 1998. p. 353–85.
11. Xi TF, Wen CR, Tian WH, Liu XH. Study on synthetic evaluation hemocompatibility of biomaterials by multiparameter testing. Transactions of the Third World Biomaterials Congress, Japan, 1988. p. 32.
12. Motto NF. Conduction in non-crystalline materials. Oxford: Clarendon Press, 1987. p. 18.
13. Rutile-type titanium oxide films synthesized by filtered arc deposition10.1016/S0257-8972(98)00691-4 ↗
14. Wettability and interfacial interactions in bioceramic-body-liquid system10.1002/jbm.820290402 ↗
15. Zhang K. Interface Sci Polymer (Chinese). Beijing, 1997. p. 58.
16. In vitro investigation of blood compatibility of Ti with oxide layer of rutile structure10.1177/088532829400800406 ↗
17. Gutmann · 1986
18. Chen JY, Huang N, Yang P, Leng YX, Sun H, Xi TF, Wu X, Chen F. Synthesis and properties study of titanium dioxide doped with tantalum. Transactions of the Sixth World Biomaterials Congress (American), 2000. p. 1026.
19. Donald LW. Biomaterials and bioengineering handbook. New York: Marcel Dekker, 2000. p. 206.
20. Buddy DR, Allan SH, Frederick JS, Jack EL. Biomaterials science: an introduction to materials in medicine. New York: Academic Press, 1996. p. 139.
21. Frederick HS, David LC. Biomaterials science and biocompatibility. New York: Springer, 1999. p. 296.