Osseointegration of machined, injection moulded and oxygen plasma modified PEEK implants in a sheep model
Source abstract
Abstract
Machined and injection moulded polyetheretherketone (PEEK) implants with and without an oxygen plasma modification were prepared and implanted in sheep cancellous and cortical bone. After 4, 12 and 26 weeks, osseointegration was evaluated through mechanical push-out tests and histomorphometry. In the cancellous bone, push-out force increased with time, a trend toward higher force was observed for machined compared to moulded, and oxygen plasma modified compared to unmodified. On-going remodelling of the bone was detected in the periphery of the implants at 4 weeks. Minimal or no inflammation was observed with all the implants at all locations and time-points. Bone-implant contact (BIC) was quantified at all-time points and locations for all the four PEEK implant surfaces. The BIC values ranged from 15 to 75% with an average of 29 ± 13% in the cancellous bone and 25-65% with an average of 50 ± 12% in the cortical bone. In the cortical bone the BIC increased significantly from 4 to 26 weeks. This in vivo study has identified that surface topography of PEEK implants influences osseointegration. In addition, oxygen plasma has the potential to increase bone-implant interface stability. This study provides a unique reference for further modifications and in vivo assessment of PEEK implants.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (47)
Show source-provided references
1. PEEK biomaterials in trauma, orthopedic, and spinal implants10.1016/j.biomaterials.2007.07.013 ↗
2. Radio frequency plasma treatment of PEEK spinal implants
3. Polyetheretherketone–cytotoxicity and mutagenicity in vitro10.1016/S0142-9612(01)00300-3 ↗
4. In vivo biocompatibility testing of PEEK polymer for a spinal implant system: a study in rabbits10.1002/jbm.10159 ↗
5. A carbon fiber implant to aid interbody lumbar fusion. Two-year clinical results in the first 26 patients10.1097/00007632-199310001-00030 ↗
6. Solis cage (PEEK) for anterior cervical fusion: preliminary radiological results with emphasis on fusion and subsidence10.1016/j.spinee.2006.03.002 ↗
7. Reconstruction of frontal bone using specific implant polyether-ether-ketone10.1097/SCS.0b013e3182326f2c ↗
8. Amorphous and crystalline polyetheretherketone: mechanical properties and tissue reactions during a 3-year follow-up10.1002/jbm.a.31310 ↗
9. Biomechanical evaluation and comparison of polyetheretherketone rod system to traditional titanium rod fixation10.1016/j.spinee.2008.08.002 ↗
10. Comparison of polyetheretherketone cages with femoral cortical bone allograft as a single-piece interbody spacer in transforaminal lumbar interbody fusion10.3171/spi.2006.5.6.534 ↗
11. Compounds and composite materials
12. The in vitro response of human osteoblasts to polyetheretherketone (PEEK) substrates compared to commercially pure titanium10.1016/j.biomaterials.2007.12.001 ↗
13. Cell adhesion to PEEK treated by plasma immersion ion implantation and deposition for active medical implants10.1002/ppap.201100034 ↗
14. Polyetheretherketone as a biomaterial for spinal applications10.1016/j.biomaterials.2005.07.011 ↗
15. Anti-infective and osteointegration properties of silicon nitride, poly(ether ether ketone), and titanium implants10.1016/j.actbio.2012.07.038 ↗
16. Improvement of bone ingrowth on PEEK surface implant10.4028/www.scientific.net/KEM.493-494.795 ↗
17. Surface activation of polyetheretherketone (PEEK) and formation of calcium phosphate coatings by precipitation10.1023/A:1018535923173 ↗
18. The electron beam deposition of titanium on polyetheretherketone (PEEK) and the resulting enhanced biological properties10.1016/j.biomaterials.2009.12.030 ↗
19. Surface functionalization of PEEK films using photochemical routes10.1016/S0014-3057(00)00094-X ↗
20. Surface modification of poly(aryl ether ether ketone) (PEEK) film by covalent coupling of amines and amino acids through a spacer arm10.1002/(SICI)1099-0518(199712)35:17<3779::AID-POLA17>3.0.CO;2-A ↗
21. Stable oxygen plasma surface modification of PEEK to improve human primary osteoblast cytocompatibility
22. Surface modification techniques of PEEK; including plasma surface treatment
23. Tailoring of poly(ether ether ketone) surface properties via surface-initiated atom transfer radical polymerization10.1021/la900010z ↗
24. Scaffold development using selective laser sintering of polyetheretherketone-hydroxyapatite biocomposite blends10.1016/S0142-9612(03)00131-5 ↗
25. Thermal processing of hydroxyapatite reinforced polyetheretherketone composites10.1016/S0924-0136(99)00060-6 ↗
26. Plasma-treatment of polyetheretherketone (PEEK) for adhesive bonding10.1016/0143-7496(96)89798-3 ↗
27. A nanoscale adhesion layer to promote cell attachment on PEEK10.1021/ja810075c ↗
28. Laser surface modification of PEEK10.1016/j.apsusc.2012.01.154 ↗
29. Surface energy effects on osteoblast spatial growth and mineralization10.1016/j.biomaterials.2007.12.026 ↗
30. Influence of substratum surface chemistry/energy and topography on the human fetal osteoblastic cell line hFOB 1.19: phenotypic and genotypic responses observed in vitro10.1016/j.biomaterials.2007.06.016 ↗
31. Poulsson AHC, Richards RG, inventors. Polymer surface modification. Switzerland patent WO2009/149827A1; 2009.
32. Analysis of interfacial sliding in brittle-matrix composites during push-out and push-back tests10.1016/S0921-5093(98)00589-9 ↗
33. Potential of polyetheretherketone (PEEK) and carbon-fibre-reinforced PEEK in medical applications10.1007/BF01728981 ↗
34. In vivo implant fixation of carbon fiber-reinforced PEEK hip prostheses in an ovine model10.1002/jor.22251 ↗
35. Novel surface modifications of carbon fiber-reinforced polyetheretherketone hip stem in an ovine model10.1111/j.1525-1594.2011.01275.x ↗
36. Biological surface science10.1016/S0039-6028(01)01809-X ↗
37. Photodegradation of PEEK sheets under tensile stress10.1016/j.polymdegradstab.2005.06.003 ↗
38. Experimental investigation into the effect of adhesion properties of PEEK modified by atmospheric pressure plasma and low pressure plasma10.1002/app.31880 ↗
39. Improved adhesion to polymer by UV/ozone surface oxidation10.1016/0143-7496(96)88482-X ↗
40. Surface dynamics vs. adhesion in oxygen plasma treated polyolefins
41. On oxygen plasma-treated polypropylene interfaces with air, water, and epoxy resins. II. Epoxy resins10.1002/app.1991.070420732 ↗
42. Plasma treatment for improved bonding – a review
43. An introduction to plasma polymerization
44. Plasma processing of biomaterials10.1163/156856292X00295 ↗
45. Coating of carbon fiber-reinforced polyetheretherketone implants with titanium to improve bone apposition10.1002/jbm.b.32861 ↗
46. Locally delivered bisphosphonate for enhancement of bone formation and implant fixation10.2106/JBJS.I.00518 ↗
47. The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: a three-dimensional finite element analysis10.1016/S0022-3913(08)60259-0 ↗