Albumin and fibrinogen adsorption on PU–PHEMA surfaces
Source abstract
Abstract
Materials that adsorb specific proteins may find a variety of applications in the biomedical field. The aim of this study was the preparation of a hydrophilic surface, with low protein adsorption, to be used in the future as a support for the immobilisation of several species, e.g. Cibacron Blue F3G-A, which has been described to induce specific albumin adsorption. Poly(hydroxyethylmethacrylate) (PHEMA) and poly(hydroxyethylacrylate) (PHEA) were chosen as the hydrophilic surface because they can be easily polymerised and possess hydroxyl groups that can be used for the immobilisation of different compounds. Thin films of PHEMA and PHEA were successfully graft polymerised onto the surface of a commercial poly(etherurethane) (PU) using ceric ion as initiator. Grafting polymerisations were followed by mass gain and attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR). Since stability tests demonstrated that only PU-PHEMA was stable in alkaline solutions, a necessary condition to future immobilisations, the investigation was focused on the coating of PU with PHEMA. PU-PHEMA films were characterised in detail using several techniques as mass gain, ATR-FTIR, contact angle measurements, X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM). Protein adsorption was evaluated using radiolabelled albumin and fibrinogen from pure solutions and from mixtures of both proteins. PU surfaces modified with PHEMA have demonstrated low protein adsorption, showing their potential use as substrates. This opens the possibly of exploring the advantages of selective adsorption by appropriate immobilisation of specific molecules.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Polymer Surface Interaction Studies · Microfluidic and Capillary Electrophoresis Applications · Nanofabrication and Lithography Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (45)
Show source-provided references
1. Ratner · 1996
2. Greco · 1994
3. Hemocompatibility
4. Glow discharge plasma deposition of tetraethylene glycol dimethyl ether for fouling-resistant biomaterials surfaces10.1002/jbm.820260402 ↗
5. Interactions between Pseudomonas Aeruginosa and plasma-deposited PEO-like thin films during initial attachment and growth
6. Effect of albumin coating on the in vitro blood compatibility of Dacron arterial prostheses10.1016/0142-9612(89)90017-3 ↗
7. Blood-biomaterial interactions in a flow system in the presence of bacterial, effect of protein adsorption10.1002/jbm.820290216 ↗
8. Adhesion of staphylococci to chemically modified and native polymers, and the influence of preadsorbed fibronectin, vitronectin and fibrinogen10.1016/0142-9612(93)90006-N ↗
9. Albumin binding surfaces for biomaterials
10. Albumin-binding surfaces for implantable devices10.1002/jbm.820260403 ↗
11. Alkyl substituted polymers with enhanced albumin affinity
12. Surface modification of polymeric biomaterials by albumin grafting using y-radiation10.1002/jab.770050210 ↗
13. Albumin binding surfaces
14. Stearyl poly(ethylene oxide) grafted surfaces for preferential adsorption of albumin10.1016/S0142-9612(01)00048-5 ↗
15. Biocompatible coatings with high albumin affinity
16. Structural changes of bovine serum albumin upon adsorption to modified fluoropolymer substrates used for neural cell attachment studies10.1021/la00003a048 ↗
17. Fibrinogen binding and platelet retention10.1002/(SICI)1097-4636(199601)30:1<101::AID-JBM13>3.0.CO;2-R ↗
18. 2-Hydroxyethyl methacrylate (HEMA)10.1080/15321799208018377 ↗
19. Reactive site and Mechanism of graft copolymerisation onto poly(ether urethane) with Ceric ion as initiator10.1021/ma00153a004 ↗
20. Horbett TA. Techniques for protein adsorption studies. In: Williams DF, editor. Techniques of biocompatibility tests, vol. 2. Harcover: CRC Press, 1986. p. 183–214.
21. Interactions between calcium, phosphate, and albumin on the surface of titanium10.1002/1097-4636(200104)55:1<45::AID-JBM70>3.0.CO;2-0 ↗
22. Iodine-125. A Guide to radioiodination techniques, Amersham Life Science, Little Chalfont, England: Amersham International plc, 1993. p. 64.
23. Schrader B. Infrared and Raman spectroscopy: methods and applications. Weinheim: VCH Publishers, Inc., (Federal Republic of German), 1995.10.1002/9783527615438 ↗
24. Lamba · 1998
25. FT-IR spectroscopic studies of polyurethanes10.1163/156856295X00553 ↗
26. Tingey KG, Andrade JD, McGary Jr CW, Zdrahala RJ. Surface analysis of commercial biomedical polyurethanes, In: Andrade JD, editor. Polymer surface dynamics. New York: Plenum Press, 1988.10.1007/978-1-4684-1291-8_11 ↗
27. Beamson · 1992
28. Plasma-induced graft copolymerisation of HEMA onto silicone rubber and TPX film improving rabbit corneal epithelial cell attachment and growth10.1016/0142-9612(94)90062-0 ↗
29. Platelet adhesion onto segmented polyurethane surfaces modified by PEO—and sulfonated PEO-containing block copolymer additives10.1002/(SICI)1097-4636(199805)40:2<314::AID-JBM17>3.0.CO;2-L ↗
30. On the wettability of poly(2-hydroxyethylmetacrylate)10.1016/0021-9797(92)90393-Z ↗
31. Surface field of forces and protein adsorption behavior of poly(hydroxyethylmethacrylate) films deposited from plasma10.1002/jbm.820290107 ↗
32. Adsorption of coagulation proteins from whole blood on to polymer materials10.1016/0142-9612(92)90086-4 ↗
33. Baboon fibrinogen adsorption and platelet adhesion to polymeric materials10.1055/s-0038-1648198 ↗
34. Adsorption of proteins from plasma to a series of hydrophilic-hydrophobic copolymers. II Compositional analysis with the prelabeled protein technique10.1002/jbm.820150506 ↗
35. Effect of charged groups on the adsorption and penetration of proteins onto and into carboxymethylated poly(HEMA) hydrogels10.1016/S0142-9612(98)00125-2 ↗
36. Protein adsorption on low temperature isotropic carbon. III. Isoterms, competitivity, desorption and exchange of albumin and fibrinogen10.1016/0142-9612(94)90243-7 ↗
37. Changes in adsorbed fibrinogen and albumin interactions with polymers indicated by decreases in detergent elutability10.1016/0021-9797(86)90040-8 ↗
38. Changes in fibrinogen adsorbed to segmented polyurethanes and hydroxyethylmethacrylate–ethylmethacrylate copolymers10.1002/jbm.820261208 ↗
39. Blood compatible aspects of poly(hydroxyethylacrylate) (PMEA)—relationship between protein adsorption and platelet adhesion on PHEA surface10.1016/S0142-9612(00)00031-4 ↗
40. Interaction of high molecular weight kininogen, Factor XII and fibrinogen in plasma at interfaces10.1182/blood.V55.1.156.156 ↗
41. Adsorption of proteins out of plasma and solutions in narrow spaces10.1016/0021-9797(86)90042-1 ↗
42. Protein adsorption and materials biocompatibility10.1007/3-540-16422-7_6 ↗
43. Vroman effects, techniques and philosophies10.1080/09205063.1991.9756657 ↗
44. Studies of protein adsorption relevant to blood compatible materials
45. Protein adsorption studies on standard polymeric materials10.1163/156856293X00230 ↗