journal article·2003-03

Effects of clinically relevant alumina ceramic wear particles on TNF-α production by human peripheral blood mononuclear phagocytes

A. Hatton, J.E. Nevelos, J.B. Matthews, J. Fisher, E. Ingham

Biomaterials· Volume 24· Issue 7
Publisher page

Abstract

The recent introduction of microseparation of the components of ceramic-on-ceramic hip prostheses during hip simulations has produced clinically relevant wear rates, wear patterns and wear particles. This provided an opportunity to determine the response of primary human peripheral blood mononuclear cells to clinically relevant alumina ceramic wear particles in vitro. Alumina ceramic wear particles were generated in a hip joint simulator under microseparation conditions. The particles showed a bi-modal size distribution with nanometer sized (5-20nm) and larger particles (0.2->10 micrometer). The particles were cultured with human peripheral blood mononuclear cells obtained from six different donors at particle volume to cell number ratios of 1, 10, 100 and 500 micrometer(3). After 24h incubation the viability of the cells and the levels of TNF-alpha were determined. The response to the microseparation wear particles was compared to that of commercially available alumina powder with a uniform morphology and mean size of 0.5 micrometer. All six Donors PBMNC produced significantly elevated levels of TNF-alpha when stimulated with 100 micrometer(3) of the alumina powder per cell. Volumetric concentrations of 10 and 1.0 micrometer(3) per cell failed to stimulate a significant response by the cells from any of the six donors. Three of the six Donors PBMNC secreted significantly elevated levels of TNF-alpha when stimulated with 100 micrometer(3) of the microseparation wear particles, whereas the other three failed to respond to the wear debris at this concentration. All of the Donors PBMNC produced significantly elevated levels of TNF-alpha when stimulated with 500 micrometer(3) of the microseparation wear particles per cell. Thus, a greater volume of the microseparation wear particles was required to activate the PBMNC than the alumina powder. This was probably due to the microseparation wear particles having fewer particles in the critical size range (0.1-1 micrometer) for macrophage activation compared to the alumina powder. It can be concluded that alumina ceramic wear particles generated under microseparation conditions are capable of inducing osteolytic cytokine production by human mononuclear phagocytes. However, the volumetric concentration of the particles needed to generate this response is extremely high and given the low wear rates (<4mm(3) per million cycles) of ceramic-on-ceramic bearings, even under severe microseparation conditions, it is unlikely that this concentration threshold will be achieved in vivo.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments · Total Knee Arthroplasty Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (40)

Show source-provided references
1. Biological reaction to debris in relation to joint prostheses. Proceedings of the Institute of Mechanical Engineers10.1243/0954411971534304 ↗
2. Biological reactions to wear debris. Proceedings of the Institute of Mechanical Engineers10.1243/0954411001535219 ↗
3. Osteolysis after Charnley primary low-friction arthroplasty. A comparison of two matched paired groups10.1302/0301-620X.80B4.7361 ↗
4. 15-21-year results of the Charnley low friction arthroplasty10.1097/00003086-198610000-00005 ↗
5. Effect of size and dose on bone resorption activity of macrophages in vitro by clinically relevant ultra high molecular weight polyethylene particles10.1002/1097-4636(200009)53:5<490::AID-JBM7>3.0.CO;2-7 ↗
6. Evaluation of the response of primary human peripheral blood mononuclear phagocytes challenged with in vitro generated clinically relevant UHMWPE particles of known size and dose10.1002/1097-4636(200011)52:2<296::AID-JBM8>3.0.CO;2-9 ↗
7. Development of an extremely wear resistant ultra high molecular weight polyethylene for total hip replacements
8. Unified wear model for highly crosslinked UHMWPE10.1016/S0142-9612(99)00039-3 ↗
9. The use of dense alumina–alumina combination in total hip replacement10.1002/jbm.820221210 ↗
10. Sixteen-years experience with ceramic hip prostheses10.1097/00003086-199209000-00008 ↗
11. Ten-year survivorship of cemented ceramic–ceramic total hip prostheses10.1097/00003086-199209000-00007 ↗
12. Long-term results of uncemented alumina acetabular implants10.1302/0301-620X.76B1.8300682 ↗
13. Roy BR, Nevelos AB, Ingham E, Shaw DL, Fisher J. Comparison of ceramic on ceramic to ceramic on polyethylene total hip replacement. Proceeding of the 13th International Symposium on Ceramics in Medicine, Bioceramics, vol. 13, Bologna, Italy, 2000.10.4028/www.scientific.net/KEM.192-195.991 ↗
14. Alumina-on-alumina total hip arthroplasty. A minimum 18.5 years follow-up study10.2106/00004623-200201000-00011 ↗
15. Unsatisfactory results with a ceramic total hip prosthesis10.2106/00004623-199072050-00004 ↗
16. Primary ceramic hip replacement10.3928/0147-7447-19910501-05 ↗
17. Massive osteolysis after ceramic-on-ceramic total hip arthroplasty10.1097/00003086-199705000-00015 ↗
18. Analysis of retrieved alumina ceramic components from Mittelmeier total hip prostheses10.1016/S0142-9612(99)00081-2 ↗
19. Comparative analysis of two different types of alumina–alumina hip prosthesis retrieved for aseptic loosening10.1302/0301-620X.83B4.0830598 ↗
20. Osteolysis in association with a total hip arthroplasty with ceramic bearing surfaces10.2106/00004623-199810000-00007 ↗
21. Gautsch TL, Freeman AM. The influence of micron and submicron particulates of orthopeadic ceramics on eicosanoid production by macrophages in vitro compared to that of PMMA. Proceedings of the 39th Orthopaedic Research Society Annual Meeting, San Francisco, California, USA, 1993. p. 267.
22. Effect of particle size on alumina-induced production of reactive oxygen metabolites by human leucocytes10.3109/03009749509099293 ↗
23. Cytotoxicity and macrophage cytokine release induced by ceramic and polyethylene particles in vitro10.1302/0301-620X.81B3.8737 ↗
24. Kim KJ, Itoh T, Kumegawa M. Soluble factors from rabbit synovial cells in response to alumina particles stimulate osteoclast mediated bone resorption. Proceedings of the 45th Orthopaedic Research Society Annual Meeting, Anaheim, California, USA, 1999. p. 24.
25. Analysis of removed Autophor ceramic-on-ceramic components from Mittelmeier total hip arthroplasties10.1016/S0883-5403(06)80006-9 ↗
26. AL2O3 against AL2O3 combination in hip endoprostheses. Histologic investigations with semiquantitative grading of revision and autopsy cases and abrasion measures10.1007/BF00120351 ↗
27. Ceramic–ceramic and metal–polyethylene total hip replacements
28. Alumina–alumina artificial hip joints-Part I: a histological analysis and characterisation of wear debris by laser capture microdissection of tissue retrieved at revision10.1016/S0142-9612(02)00047-9 ↗
29. Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns10.1054/arth.2000.8100 ↗
30. Long-term wear of HIPed alumina bearings for THR under microseparation conditions10.1023/A:1012802308636 ↗
31. Alumina-alumina artificial hip joints-Part II: characterisation of the wear debris from in vitro hip joint simulations10.1016/S0142-9612(02)00048-0 ↗
32. Influence of cytokine genotypes on allograft rejection10.1016/S0041-1345(98)00077-3 ↗
33. A novel three-dimensional tissue equivalent model to study the combined effects of cyclic mechanical strain and wear particles on the osteolytic potential of primary human macrophages in vitro. Proceedings of the Institute of Mechanical Engineers10.1243/0954411011536073 ↗
34. Sokal RR, Rohlf FJ. In: Sokal RR, Rohlf FJ, editors. Biometry. Non-parametric methods in lieu of single classification anova. New York: W.H. Freeman Company, 1981. p. 443–5 [chapter 13].
35. Cho DR, Hong CY, Baran GR, Goldring SR. Adsorbed endotoxin mediates differential effects on particle-induced stimulation of cytokine and chemokine release. Proceedings of the 45th Annual Meeting of the Orthopaedic Research Society, Anaheim, California, USA, 1999. p. 6.10.1109/IEMBS.1999.803924 ↗
36. Ingham E, Green TR, Matthews JB, Stone MH, Fisher J. Influence of TNF-α in polyethylene particle stimulated macrophage bone resorption. Proceedings of the 45th Annual Meeting of the Orthopaedic Research Society, Anaheim, California, USA, 1999. p. 899.
37. Schwarz E, Bukata SV, Benz E, Rosier RN, Puzas JE, O‘Keefe RJ. NFKB and TNF-α are stimulated by titanium particles and are essential for in vivo bone resorption. Proceedings of the 45th Annual Meeting of the Orthopaedic Research Society, Anaheim, California, USA, 1999. p. 305.
38. Cytokine gene polymorphisms and heart transplant rejection10.1097/00007890-199709150-00021 ↗
39. Comparison of the response of three human monocytic cell lines to challenge with polyethylene particles of known size and dose10.1023/A:1008967200706 ↗
40. Quantitative comparison of polyethylene wear debris, wear rate and head damage in retrieved Charnley hip prostheses10.1023/A:1008901302646 ↗