journal article·2007-12

The lexicon of polyethylene wear in artificial joints

Harry A. McKellop

Biomaterials· Volume 28· Issue 34
Publisher page

Abstract

The analysis of wear on polyethylene components that have been retrieved after use in patients has provided invaluable understanding of how wear occurs in vivo, and how it may be minimized through improved materials and implant design. The great number of such studies that have been published over the past three decades has lead to an extensive vocabulary to describe the tribology of prosthetic joints. However, these also have led to some confusion, due to the occasional misuse of terms from classical tribology, along with the use of multiple terms to describe the same wear phenomenon, and vice versa. The author has proposed that our understanding of wear in artificial joints may be enhanced by recognizing that there are four general subject areas: Modes, Mechanisms, Damage and Debris. Wear Mode 1 occurs when the two bearing surfaces are articulating against each other in the manner intended by the implant designer. Mode 2 occurs when a bearing surface articulates against a non-bearing surface. Mode 3 occurs when third-body abrasive particles have become entrapped between the two bearing surfaces, and Mode 4 occurs when two non-bearing surfaces are wearing against each other. The least wear occurs in Mode 1, whereas severe wear typically occurs in Modes 2, 3 and 4. The classical wear mechanisms that apply to prosthetic joints include adhesion, abrasion and fatigue. These can occur in varying amounts in either of the four wear modes. As used in the literature for the past three decades, wear "damage" can best be defined as the change surface texture or morphology that is caused by the action of the wear mechanisms. Although a wide variety of terms have been used, an overview of the literature indicates that about eight terms have been sufficient to describe the types of damage that occur on retrieved polyethylene components, i.e., burnishing, abrasion, scratches, plastic deformation, cracks, pits, delamination, and embedded third bodies. The author suggests that, as far as possible, investigators endeavor to limit their descriptions of surface damage to these terms and, importantly, to clearly and consistently distinguish the classical wear mechanisms from the types of damage produced by those mechanisms. Wear debris refers to the billions of particles, some measuring in nanometers, that are generated by the wear mechanisms, and that initiate biological reactions, such as osteolysis, that may lead to the failure of the implant. As the methods for recovering wear debris from joint fluids and tissues are improved, investigators are using a growing number of terms to describe them. As with the types of damage, it will be important in the coming years to maximize clarity and minimize redundancy of the vocabulary in this important area of research.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Orthopedic Infections and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (46)

Show source-provided references
1. Replacement of arthritic hips by the McKee-Farrar prosthesis10.1302/0301-620X.48B2.245 ↗
2. The nine and ten year results of the low-friction arthroplasty of the hip10.1097/00003086-197309000-00003 ↗
3. Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty10.1016/S0142-9612(99)00053-8 ↗
4. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements10.1002/jor.1100170203 ↗
5. Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements10.1016/S0301-679X(98)00005-X ↗
6. Five-year experience with crossfire(r) highly cross-linked polyethylene10.1097/00003086-200512000-00024 ↗
7. A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked marathon and non-cross-linked enduron polyethylene liners10.1016/j.arth.2006.05.002 ↗
8. Metallic wear in total knee replacements
9. McKellop H. Assessment of wear of materials for artificial joints. In: J. Callaghan, A. Rosenberg, H. Rubash, editors. The adult hip. New York: Lippencott-Raven; 1998. p. 231–46.
10. McKellop HA, Wear modes, mechanisms, damage, and debris. Separating cause from effect in the wear of total hip replacements. In: J. O. Galante, A. G. Rosenberg, J. J. Callaghan, editors. Total hip revision surgery. New York: Raven Press, Ltd.; 1995. p. 21–39.
11. Optical analysis of surface changes on early retrievals of highly cross-linked and conventional polyethylene tibial inserts10.1016/S0883-5403(03)00293-6 ↗
12. Comparison of the bearing performance of normal and artificial human joints
13. A comparative study of total hip replacement prostheses10.1016/0021-9290(73)90052-3 ↗
14. Wear and conformity in total knee replacement10.1016/0043-1648(76)90003-X ↗
15. Brown KJ, Atkinson JR, et al., The wear of ultra-high molecular weight polyethylene with reference to its use in prostheses. Plastics in medicine and surgery. London: Plastics and Rubber Institute;1975. p. 2.1–5.
16. The characteristics of acetabular cups worn in the human body10.1302/0301-620X.60B3.681413 ↗
17. The appearances of wear on polyethylene–a comparison of in vivo and in vitro wear surfaces10.1002/jbm.820120306 ↗
18. On the origins of high in vivo wear rates in polyethylene components of total joint prostheses10.1097/00003086-197911000-00044 ↗
19. Retrieval analysis of total knee prostheses: a method and its application to 48 total condylar prostheses10.1002/jbm.820170510 ↗
20. Wear of Ultra-high-molecular-weight polyethylene components of 90 retrieved knee prostheses10.1016/S0883-5403(88)80013-5 ↗
21. The correlation between fusion defects and damage in tibial polyethylene bearings
22. Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty10.1097/00003086-199402000-00005 ↗
23. A quantitative technique for reporting surface degradation patterns of UHMWPE components of retrieved total knee replacements10.1002/jab.770060103 ↗
24. Wear of polyethylene cups in total hip arthroplasty. A study of specimens retrieved post mortem10.2106/00004623-199608000-00009 ↗
25. Effects of sterilization on wear in total knee arthroplasty10.1097/00003086-199610000-00023 ↗
26. The impact of sterilization method on wear in knee arthroplasty10.1097/00003086-199811000-00024 ↗
27. The relationship between the clinical performance and large deformation mechanical behavior of retrieved UHMWPE tibial inserts10.1016/S0142-9612(99)00178-7 ↗
28. Effect of resin type and manufacturing method on wear of polyethylene tibial components10.1097/00003086-200007000-00023 ↗
29. Polyethylene damage and knee kinematics after total knee arthroplasty10.1097/00003086-200111000-00050 ↗
30. Tibial post wear in posterior stabilized total knee arthroplasty. An unrecognized source of polyethylene debris10.2106/00004623-200103000-00011 ↗
31. Surface damage in machined ram-extruded and net-shape molded retrieved polyethylene tibial inserts of total knee replacements10.2106/00004623-200209000-00005 ↗
32. Coventry award paper. Backsurface wear and deformation in polyethylene tibial inserts retrieved postmortem10.1097/00003086-200211000-00004 ↗
33. Polyethylene damage in total knees and use of highly crosslinked polyethylene10.2106/00004623-200300001-00003 ↗
34. Surface damage on open box posterior-stabilized polyethylene tibial inserts10.1097/01.blo.0000092998.90435.98 ↗
35. Backside wear of modular ultra-high molecular weight polyethylene tibial inserts10.2106/00004623-200405000-00022 ↗
36. Factors affecting the severity of backside wear of modular tibial inserts10.2106/00004623-200402000-00013 ↗
37. Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners10.2106/00004623-200406000-00021 ↗
38. Polyethylene wear and rim fracture in total disc arthroplasty10.1016/j.spinee.2006.05.012 ↗
39. Basic mechanisms of friction and wear of polymers
40. Wear characteristics of UHMW polyethylene: a method for accurately measuring extremely low wear rates10.1002/jbm.820120611 ↗
41. A literature review of the association between wear rate and osteolysis in total hip arthroplasty10.1054/arth.2002.33664 ↗
42. Correlation of wear debris-induced osteolysis and revision with volumetric wear-rates of polyethylene: a survey of 8 reports in the literature10.1080/000164701753606644 ↗
43. Isolation of predominantly submicron-sized UHMWPE wear particles from periprosthetic tissues10.1002/jbm.820290118 ↗
44. Hailey JL, Ingham E, et al. Ultra-high molecular weight polyethylene wear debris generated in vivo and in laboratory tests; the influence of counterface roughness (Proc Inst Mech Eng [H] 1996;210(1): 3–10).10.1243/PIME_PROC_1996_210_385_02 ↗
45. Shanbhag · 1995
46. The origin of submicron polyethylene wear debris in total hip arthroplasty