The role of poly(ethylene glycol) brush architecture in complement activation on targeted microbubble surfaces
Source abstract
Abstract
Complement fixation to surface-conjugated ligands plays a critical role in determining the fate of targeted colloidal particles after intravenous injection. In the present study, we examined the immunogenicity of targeted microbubbles with various surface architectures and ligand surface densities using a flow cytometry technique. Targeted microbubbles were generated using a post-labeling technique with a physiological targeting ligand, cyclic arginine-glycine-asparagine (RGD), attached to the distal end of the poly(ethylene glycol) (PEG) moieties on the microbubble surface. Microbubbles were incubated in human serum, washed and then mixed with fluorescent antibodies specific for various serum components. We found that complement C3/C3b was the main human serum factor to bind in vitro to the microbubble surface, compared to IgG or albumin. We also investigated the effect of PEG brush architecture on C3/C3b fixation to the microbubble surface. RGD peptide was able to trigger a complement immune response, and complement C3/C3b fixation depended on microbubble size and RGD peptide surface density. When the targeting ligand was attached to shorter PEG chains that were shielded by a PEG overbrush layer (buried-ligand architecture), significantly less complement activation was observed when compared to the more traditional exposed-ligand motif. The extent of this protective role by the PEG chains depended on the overbrush length. Taken together, our results confirm that the buried-ligand architecture may significantly reduce ligand-mediated immunogenicity. More generally, this study illustrates the use of flow cytometry and microbubbles to analyze the surface interactions between complex biological media and surface-engineered biomaterials.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Inhalation and Respiratory Drug Delivery · Ultrasound and Hyperthermia Applications · Nanoparticle-Based Drug Delivery
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (47)
Show source-provided references
1. Injectable microbubbles as contrast agents for diagnostic ultrasound imaging: the key role of perfluorochemicals10.1002/anie.200200550 ↗
2. Microbubble ultrasound contrast agents: an update10.1007/s00330-007-0623-0 ↗
3. Ultrasound microbubble contrast agents: fundamentals and application to gene and drug delivery10.1146/annurev.bioeng.8.061505.095852 ↗
4. Microbubble ultrasound contrast agents: a review10.1243/09544110360729072 ↗
5. Microbubbles and ultrasound: from diagnosis to therapy10.1016/j.euje.2004.02.001 ↗
6. Microbubbles in medical imaging: current applications and future directions10.1038/nrd1417 ↗
7. Microbubble compositions, properties and biomedical applications10.1179/175889709X446507 ↗
8. Targeted ultrasonic contrast agents for molecular imaging and therapy10.1053/pcad.2001.26440 ↗
9. Anti-alpha v integrin monoclonal antibody intetumumab enhances the efficacy of radiation therapy and reduces metastasis of human cancer xenografts in nude rats10.1158/0008-5472.CAN-10-1639 ↗
10. scVEGF microbubble ultrasound contrast agents: a novel probe for ultrasound molecular imaging of tumor angiogenesis10.1097/RLI.0b013e3181efd581 ↗
11. Ultrasound molecular imaging of VEGFR2 in a rat prostate tumor model using BR5510.1097/RLI.0b013e3181ee8b83 ↗
12. Delivery of TFPI-2 using SonoVue and adenovirus results in the suppression of thrombosis and arterial re-stenosis10.1258/ebm.2010.010046 ↗
13. Contrast-enhanced ultrasonography and spiral computed tomography in the detection and characterization of portal vein thrombosis complicating hepatocellular carcinoma10.1007/s00330-008-0931-z ↗
14. Molecular imaging of inflammation in atherosclerosis with targeted ultrasound detection of vascular cell adhesion molecule-110.1161/CIRCULATIONAHA.106.684738 ↗
15. Microbubble persistence in the microcirculation during ischemia/reperfusion and inflammation is caused by integrin- and complement-mediated adherence to activated leukocytes10.1161/01.CIR.101.6.668 ↗
16. Molecular imaging of the initial inflammatory response in atherosclerosis: implications for early detection of disease10.1161/ATVBAHA.109.196386 ↗
17. Targeted ultrasound contrast agents
18. Amphipathic polyethyleneglycols effectively prolong the circulation time of liposomes10.1016/0014-5793(90)81016-H ↗
19. Targeted delivery of gas-filled microspheres, contrast agents for ultrasound imaging10.1016/S0169-409X(98)00104-5 ↗
20. Microvascular rheology of definity microbubbles after intra-arterial and intravenous administration10.1067/mje.2002.117290 ↗
21. Effect of microbubble size on fundamental mode high frequency ultrasound imaging in mice10.1016/j.ultrasmedbio.2010.03.015 ↗
22. Relationship between complement activation, cellular uptake and surface physicochemical aspects of novel PEG-modified nanocapsules10.1016/S0142-9612(01)00043-6 ↗
23. Enhanced hepatic-uptake of liposomes through complement activation depending on the size of liposomes10.1023/A:1018965121222 ↗
24. Murphy · 2008
25. Lodish · 2008
26. Phagocytosis of ultrasound contrast agent microbubbles by kupffer cells10.1016/j.ultrasmedbio.2006.08.008 ↗
27. Initial observations on the effect of irradiation on the liver-specific uptake of levovist10.1016/S0720-048X(01)00458-2 ↗
28. Evidence for spleen-specific uptake of a microbubble contrast agent: a quantitative study in healthy volunteers10.1148/radiol.2313030544 ↗
29. Complement activation-related pseudoallergy caused by amphiphilic drug carriers: the role of lipoproteins10.2174/156720105774370212 ↗
30. Peptide-based molecules in angiogenesis10.1111/j.1747-0285.2006.00356.x ↗
31. Imaging angiogenesis: applications and potential for drug development10.1093/jnci/dji023 ↗
32. Complement activation-related pseudoallergy: a new class of drug-induced acute immune toxicity10.1016/j.tox.2005.07.023 ↗
33. Complement activation cascade triggered by PEG-PL engineered nanomedicines and carbon nanotubes: the challenges ahead10.1016/j.jconrel.2010.04.003 ↗
34. Liposome-mediated triggering of complement cascade10.1080/08982100802309552 ↗
35. Stealth liposomes and long circulating nanoparticles: critical issues in pharmacokinetics, opsonization and protein-binding properties10.1016/S0163-7827(03)00033-X ↗
36. Methylation of the phosphate oxygen moiety of phospholipid-methoxy(polyethylene glycol) conjugate prevents PEGylated liposome-mediated complement activation and anaphylatoxin production10.1096/fj.06-6186fje ↗
37. Ultrasound radiation force modulates ligand availability on targeted contrast agents10.2310/7290.2006.00016 ↗
38. A stimulus-responsive contrast agent for ultrasound molecular imaging10.1016/j.biomaterials.2007.10.011 ↗
39. Microbubble size isolation by differential centrifugation10.1016/j.jcis.2008.09.066 ↗
40. Ligand conjugation to bimodal poly(ethylene glycol) brush layers on microbubbles10.1021/la101796p ↗
41. A tumor vasculature targeted liposome delivery system for combretastatin A4: design, characterization, and in vitro evaluation10.1208/pt070232 ↗
42. Preparation of RGD-modified long circulating liposome loading matrine, and its in vitro anti-cancer effects10.7150/ijms.7.197 ↗
43. Complement activation on surfaces carrying amino groups10.1016/j.biomaterials.2007.10.005 ↗
44. Activation of the human complement system by cholesterol-rich and PEGylated liposomes - modulation of cholesterol-rich liposome-mediated complement activation by elevated serum LDL and HDL levels10.1080/08982100600848801 ↗
45. Incidence of adverse events associated with use of perflutren contrast agents for echocardiography10.1001/jama.299.17.2023 ↗
46. The safety of definity and optison for ultrasound image enhancement: a retrospective analysis of 78,383 administered contrast doses10.1016/j.echo.2008.07.019 ↗
47. Ultrasound contrast agent safety from anecdote to evidence