journal article·2016-10Open access

In vivo biodistribution studies and ex vivo lymph node imaging using heavy metal-free quantum dots

Elnaz Yaghini, Helen D. Turner, Alix M. Le Marois, Klaus Suhling, Imad Naasani, Alexander J. MacRobert

Biomaterials· Volume 104

Abstract

Quantum dots (QDs) are attractive photoluminescence probes for biomedical imaging due to their unique photophysical properties. However, the potential toxicity of QDs has remained a major obstacle to their clinical use because they commonly incorporate the toxic heavy metal cadmium within the core of the QDs. In this work, we have evaluated a novel type of heavy metal-free/cadmium-free and biocompatible QD nanoparticles (bio CFQD(®) nanoparticles) with a good photoluminescence quantum yield. Sentinel lymph node mapping is an increasingly important treatment option in the management of breast cancer. We have demonstrated their potential for lymph node mapping by ex vivo imaging of regional lymph nodes after subcutaneous injection in the paw of rats. Using photoluminescence imaging and chemical extraction measurements based on elemental analysis by inductively coupled plasma mass spectroscopy, the quantum dots are shown to accumulate quickly and selectively in the axillary and thoracic regional lymph nodes. In addition, lifetime imaging microscopy of the QD photoluminescence indicates minimal perturbation to their photoluminescence properties in biological systems.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Advanced Biosensing Techniques and Applications · Breast Cancer Treatment Studies · Advanced biosensing and bioanalysis techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (68)

Show source-provided references
1. Metastasis: recent discoveries and novel treatment strategies10.1016/S0140-6736(07)60781-8 ↗
2. Insights into the mechanisms of lymph node metastasis10.1002/cncr.11464 ↗
3. Morbidity after sentinel lymph node biopsy in primary breast cancer: results from a randomized controlled trial10.1200/JCO.2005.03.228 ↗
4. Surgical morbidity after mastectomy operations10.1016/0002-9610(78)90103-4 ↗
5. Randomized multicenter trial of sentinel node biopsy versus standard axillary treatment in operable breast cancer: the ALMANAC Trial10.1093/jnci/djj158 ↗
6. An approach for the treatment of penile carcinoma10.1002/1097-0142(197702)39:2<456::AID-CNCR2820390214>3.0.CO;2-I ↗
7. Observations on a “sentinel node” in cancer of the parotid10.1002/1097-0142(196001/02)13:1<77::AID-CNCR2820130114>3.0.CO;2-D ↗
8. Clinical role of sentinel-lymph-node biopsy in breast cancer10.1016/S1470-2045(02)00652-6 ↗
9. Lymphatic mapping and sentinel node biopsy in the patient with breast cancer10.1001/jama.1996.03540220042028 ↗
10. Detection of the sentinel lymph node in breast cancer10.1093/bmb/ldm032 ↗
11. Sentinel node imaging in breast cancer using superficial injections: technical details and observations10.1016/j.ejso.2009.05.006 ↗
12. Factors affecting failed localisation and false-negative rates of sentinel node biopsy in breast cancer–results of the ALMANAC validation phase10.1007/s10549-006-9192-1 ↗
13. Lymphatic mapping and sentinel lymphadenectomy for breast cancer10.1097/00000658-199409000-00015 ↗
14. Adverse reactions to patent blue V dye - the NEW START and ALMANAC experience10.1016/j.ejso.2009.10.007 ↗
15. Anaphylactic reactions to isosulfan blue dye during sentinel lymph node biopsy for breast cancer10.1016/S0002-9610(01)00734-6 ↗
16. Radioguided sentinel lymph node biopsy in breast cancer surgery
17. Surgical resection and radiolocalization of the sentinel lymph node in breast cancer using a gamma probe10.1016/0960-7404(93)90064-6 ↗
18. Intraoperative sentinel lymph node mapping using a new sterilizable magnetometer in patients with nonsmall cell lung cancer10.1016/j.athoracsur.2005.06.005 ↗
19. A novel method for sentinel lymph node mapping using magnetite in patients with non-small cell lung cancer10.1016/S0022-5223(03)00216-2 ↗
20. Sentinel lymph node biopsy in patients with breast cancer using superparamagnetic iron oxide and a magnetometer10.1007/s12282-011-0327-9 ↗
21. Sentinel node biopsy using a magnetic tracer versus standard technique: the SentiMAG Multicentre Trial10.1245/s10434-013-3379-6 ↗
22. The clinical use of indocyanine green as a near-infrared fluorescent contrast agent for image-guided oncologic surgery10.1002/jso.21943 ↗
23. Assessment of inflow and washout of indocyanine green in the adult human brain by monitoring of diffuse reflectance at large source-detector separation10.1117/1.3574018 ↗
24. Sentinel node biopsy guided by indocyanine green dye in breast Cancer patient
25. Imaging of lymph flow in breast cancer patients after microdose administration of a near-infrared fluorophore: feasibility study10.1148/radiol.2463070962 ↗
26. Semiconductor quantum dots as biological imaging agents10.1002/anie.200301758 ↗
27. Quantum dots as a platform for nanoparticle drug delivery vehicle design10.1016/j.addr.2012.09.036 ↗
28. Design of new quantum dot materials for deep tissue infrared imaging10.1016/j.addr.2012.08.016 ↗
29. Fluorescence lifetime imaging and FRET-induced intracellular redistribution of Tat-Conjugated quantum dot nanoparticles through interaction with a phthalocyanine photosensitiser10.1002/smll.201301459 ↗
30. Quantum dots versus organic dyes as fluorescent labels10.1038/nmeth.1248 ↗
31. Quantum dots: bright and versatile in vitro and in vivo fluorescence imaging biosensors10.1039/C4CS00532E ↗
32. Quantum dots-based tissue and in vivo imaging in breast cancer researches: current status and future perspectives10.1007/s10549-015-3363-x ↗
33. Sentinel lymph node imaging using quantum dots in mouse tumor models10.1021/bc060261j ↗
34. Near-infrared fluorescent type II quantum dots for sentinel lymph node mapping10.1038/nbt920 ↗
35. Sentinel lymph node mapping of the pleural space10.1378/chest.127.5.1799 ↗
36. Intraoperative identification of esophageal sentinel lymph nodes with near-infrared fluorescence imaging10.1016/j.jtcvs.2004.08.001 ↗
37. Intraoperative sentinel lymph node mapping of the lung using near-infrared fluorescent quantum dots10.1016/j.athoracsur.2004.06.055 ↗
38. Sentinel lymph node mapping of the gastrointestinal tract by using invisible light10.1245/ASO.2006.04.025 ↗
39. Simultaneous multicolor imaging of five different lymphatic basins using quantum dots10.1021/nl0707003 ↗
40. Size series of small indium arsenide-zinc selenide core-shell nanocrystals and their application to in vivo imaging10.1021/ja0579816 ↗
41. Visualisation of sentinel lymph node with indium-based near infrared emitting quantum dots in a murine metastatic breast cancer model10.1371/journal.pone.0044433 ↗
42. Inhibition of autophagy overcomes the nanotoxicity elicited by cadmium-based quantum dots10.1016/j.biomaterials.2015.11.029 ↗
43. Unmodified cadmium telluride quantum dots induce reactive oxygen species formation leading to multiple organelle damage and cell death10.1016/j.chembiol.2005.09.008 ↗
44. In vitro toxicity assessment of amphiphillic polymer-coated CdSe/ZnS quantum dots in two human liver cell models10.1021/nn302288r ↗
45. Cadmium-free CuInS2/ZnS quantum dots for sentinel lymph node imaging with reduced toxicity10.1021/nn901421v ↗
46. Magnetically engineered Cd-free quantum dots as dual-modality probes for fluorescence/magnetic resonance imaging of tumors10.1016/j.biomaterials.2013.10.078 ↗
47. Ultrasmall near-infrared non-cadmium quantum dots for in vivo tumor imaging10.1002/smll.200901672 ↗
48. InP/ZnS as a safer alternative to CdSe/ZnS core/shell quantum dots: in vitro and in vivo toxicity assessment10.1039/C2NR33024E ↗
49. Folate-receptor-mediated delivery of InP quantum dots for bioimaging using confocal and two-photon microscopy10.1021/ja051455x ↗
50. Imaging pancreatic cancer using bioconjugated InP quantum dots10.1021/nn8008933 ↗
51. Engineering InAs(x)P(1-x)/InP/ZnSe III-V alloyed core/shell quantum dots for the near-infrared10.1021/ja0434331 ↗
52. Synthesis and characterization of near-infrared Cu-In-Se/ZnS core/shell quantum dots for in vivo imaging10.1021/cm101881b ↗
53. Pikett N, Daniels S, Mushtaq I, inventors; Preparation of Nanoparticle Materials. US Patent 7,588,828.7,588,828 B2. 2009.
54. Naasani I, inventor; Surface Modified Nanoparticles. US Patent 9,115,097.9,115,097. 2015.
55. Tissue- and organ-selective biodistribution of NIR fluorescent quantum dots10.1021/nl900872r ↗
56. In vivo fluorescence imaging with Ag2S quantum dots in the second near-infrared region10.1002/anie.201206059 ↗
57. Method for analysis of nanoparticle hemolytic properties in vitro10.1021/nl0805615 ↗
58. An evaluation of blood compatibility of silver nanoparticles
59. Blood circulation and tissue biodistribution of lipid–quantum dot (L-QD) hybrid vesicles intravenously administered in mice10.1021/bc900047n ↗
60. Cytotoxicity of cadmium-free quantum dots and their use in cell bioimaging10.1021/tx5000975 ↗
61. The challenge to relate the physicochemical properties of colloidal nanoparticles to their cytotoxicity10.1021/ar300039j ↗
62. Fluorescence imaging and whole-body biodistribution of near-infrared-emitting quantum dots after subcutaneous injection for regional lymph node mapping in mice10.1007/s11307-009-0288-y ↗
63. Migration of intradermally injected quantum dots to sentinel organs in mice10.1093/toxsci/kfm074 ↗
64. Renal clearance of quantum dots10.1038/nbt1340 ↗
65. Time-resolved fluorescence microscopy10.1039/b412924p ↗
66. Fluorescence lifetime imaging (FLIM): basic concepts and some recent developments10.1016/j.medpho.2014.12.001 ↗
67. The interactions between a small molecule and G-quadruplexes are visualized by fluorescence lifetime imaging microscopy10.1038/ncomms9178 ↗
68. The correct use of “average” fluorescence parameters