The past, present, and the future of disc nucleus replacement. A systematic review of a large diversity of ideas and experiences
Source abstract
Abstract
Disc nucleus replacement (NR) is a challenging surgical technique used as a medical treatment for early-stage disc herniation to restore disc height and the biomechanical function of a motion segment, which may reduce low back pain. The surgical procedure involves the removal and replacement of the degenerated nucleus pulposus with a substitute by accessing the annulus fibrosos via a created hole. Over the decades, nucleus replacement has been an important issue, leading to the development of different substitute alternatives. The first ideas are dated to the 1950s and since then, more than a hundred nucleus replacement concepts can be identified. There were numerous attempts and several clinical trials; however, after more than 70 years of research, no gold standard for nucleus pulposus replacement has been identified. This review aims to collect the different nucleus replacements reported in the literature, thus understanding what failed, what could be improved and what are the opportunities for the future. A systematic review of the literature was performed using a keyword-based search on PubMed, Web of Science, and Scopus databases to detect all nucleus replacements presented in the past by clinicians and engineers. Several studies were extracted from which the main nucleus replacements over the years were investigated, including the ones that received CE mark, FDA approval, or IDE approval and, also those involved in clinical trials. A total of 116 studies were included in this review. The extracted data concern the nucleus replacements proposed over the years to create a historical background as complete as possible, including their mechanical and biomechanical characterization and the clinical trials conducted over the years. Nucleus disc arthroplasty has been explored for many years. Unfortunately, even today there is still nothing safe and definitive in this surgical practice. This review provides an overview of the nucleus replacement history. A breakthrough could be the improvements in technologies for the annulus fibrous closing or sealing and the tissue engineering and medical regenerative techniques which could certainly ensure a higher NR implantation success rate in the future of this clinical treatment. It is not yet clear what is the future of this clinical practice. Only scientific research can answer the question: is the nucleus replacement still a possible clinical solution?
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Spine and Intervertebral Disc Pathology · Musculoskeletal pain and rehabilitation · Shoulder Injury and Treatment
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (100+)
Show source-provided references
1. Elastic fibres in the anulus fibrosus of the adult human lumbar intervertebral disc. A preliminary report
2. A mechanical model for the human intervertebral disc10.1016/0021-9290(87)90144-8 ↗
3. Investigation of the laminate structure of lumbar disc anulus fibrosus10.1097/00007632-199005000-00011 ↗
4. Swelling pressure of the inervertebral disc: influence of proteoglycan and collagen contents10.3233/BIR-1985-22205 ↗
5. The relation between intervertebral disc bulging and annular fiber associated strains for simple and complex loading10.1016/j.jbiomech.2007.11.019 ↗
6. Stress analysis of the lumbar disc-body unit in compression. A three-dimensional nonlinear finite element study10.1097/00007632-198403000-00003 ↗
7. Some mechanical properties of the lumbar intervertebral disc
8. Effect of a prosthetic disc nucleus on the mobility and disc height of the L4–5 intervertebral disc postnucleotomy10.3171/spi.2001.95.2.0208 ↗
9. New in vivo measurements of pressures in the intervertebral disc in daily life10.1097/00007632-199904150-00005 ↗
10. Global low back pain prevalence and years lived with disability from 1990 to 2017: estimates from the Global Burden of Disease Study 201710.21037/atm.2020.02.175 ↗
11. The effect of nucleotomy on lumbar spine mechanics in compression and shear loading10.1097/00007632-200110010-00007 ↗
12. Spine arthroplasty: a historical review10.1007/s00586-002-0474-y ↗
13. Basic science of spinal degeneration
14. Is a collagen scaffold for a tissue engineered nucleus replacement capable of restoring disc height and stability in an animal model?10.1007/s00586-006-0177-x ↗
15. Effect of a nucleus prosthetic device on the biomechanical behavior of the functional spinal unit
16. 2021
17. Clinical outcomes after lumbar discectomy for sciatica: the effects of fragment type and anular competence10.2106/00004623-200301000-00016 ↗
18. Outcome after lumbar sequestrectomy compared with microdiscectomy: a prospective randomized study10.3171/spi.2005.2.3.0271 ↗
19. Nerve roots and spinal nerves in degenerative disk disease10.1097/00003086-197711000-00005 ↗
20. Microlumbar discectomy: a conservative surgical approach to the virgin herniated lumbar disc10.1097/00007632-197806000-00015 ↗
21. Kinematics of the whole lumbar spine: effect of discectomy10.1097/00007632-198507000-00008 ↗
22. Percutaneous nucleotomy: an alternative to spinal surgery10.1007/BF00449928 ↗
23. Can prevention of a re-herniation be investigated?: establishment of a herniation model and experiments with an anular closure device10.1097/BRS.0b013e31828ca4bc ↗
24. Non-fusion technology in degenerative lumbar spinal disorders: facts, questions, challenges10.1007/s00586-002-0445-3 ↗
25. The surgical and medical perioperative complications of anterior spinal fusion surgery in the thoracic and lumbar spine in adults: a review of 1223 procedures10.1097/00007632-199507150-00007 ↗
26. Current concepts in intervertebral disk restoration10.1016/S0030-5898(05)70163-2 ↗
27. The artificial disc: theory, design and materials10.1016/0142-9612(96)84936-2 ↗
28. Nuclear replacement strategies10.1016/S0030-5898(03)00007-5 ↗
29. New developments in nucleus pulposus replacement technology10.1016/j.spinee.2004.07.030 ↗
30. Nucleus pulposus replacement: basic science and indications for clinical use10.1097/01.brs.0000174530.88585.32 ↗
31. Motion-preserving technologies for degenerative lumbar spine: the past, present, and future horizons10.1016/j.esas.2011.05.001 ↗
32. Spinal arthroplasty10.3171/foc.2002.13.2.11 ↗
33. Concepts in nuclear replacement10.1016/j.spinee.2004.07.029 ↗
34. Biomaterials for intervertebral disc regeneration and repair10.1016/j.biomaterials.2017.03.013 ↗
35. Artificial nucleus replacement: clinical experience10.1097/00007632-200206150-00022 ↗
36. Biomechanical evaluation of conventional anulus fibrosus closure methods required for nucleus replacement
37. Nucleus replacement could get a new chance with annulus closure10.1007/s00586-020-06419-2 ↗
38. Challenges and strategies in the repair of ruptured annulus fibrosus10.22203/eCM.v025a01 ↗
39. Annulus fibrosus repair using genetically engineered silk and genipin-enhanced fibringel10.1055/s-0036-1582588 ↗
40. Mechanical restoration and failure analyses of a hydrogel and scaffold composite strategy for annulus fibrosus repair10.1016/j.actbio.2015.11.015 ↗
41. Artificial intervertebral discs and beyond: a north American spine society annual meeting symposium10.1016/S1529-9430(02)00540-5 ↗
42. Nucleus pulposus replacement: an emerging technology10.1016/j.spinee.2005.02.021 ↗
43. The use of methylacrylic for spinal stabilization after disc operations
44. Lumbar partial disc replacement10.1016/j.ocl.2005.03.006 ↗
45. Mechanical testing of a novel hydrogel nucleus replacement implant10.1016/j.spinee.2004.12.004 ↗
46. W.B. Hamby, EXPERIMENTAL STUDY OF EFFECTS UPON TISSUES AND REPORT OF A SMALL CLINICAL SERIES, (n.d.).
47. Bone cement as replacement material of cervical disks
48. Intractable headache and cervico-brachialgia treated by complete replacement of tabiliz intervertebral discs with a metal prosthesis
49. The Fernstrom ball revisited10.1007/s00586-011-2040-y ↗
50. Intervertebral disc prostheses10.1097/01.BRS.0000076843.59883.E1 ↗
51. History and evolution of disc replacement10.1016/j.spinee.2004.07.005 ↗
52. Ulf Fernström (1915–1985) and his contributions to the development of artificial disc replacements10.1016/j.wneu.2016.10.135 ↗
53. Intervertebral disc prosthesis and instruments for locating same
54. Suggestions for a total elasto-dynamic intervertebral disc prosthesis10.3109/10731198109117602 ↗
55. Some additional suggestions for an intervertebral disc prosthesis10.1016/0141-5425(85)90010-X ↗
56. Stepwise reduction of functional spinal structures increase vertebral translation and intradiscal pressure10.1016/j.jbiomech.2006.03.016 ↗
57. Hydrogel intervertebral disc nucleus implantation method
58. Ventral discectomy with PMMA interbody fusion for cervical disc disease: long-term results in 249 patients10.1097/00007632-200102010-00009 ↗
59. Lumbar intervertebral disc prosthesis
60. Scaffolding in tissue engineering: general approaches and tissue-specific considerations10.1007/s00586-008-0745-3 ↗
61. Artificial disc technology10.3171/foc.2000.9.4.14 ↗
62. Disk replacement arthroplasties: can the success of hip and knee replacements be repeated in the spine?10.1053/S1040-7383(03)00077-7 ↗
63. The PDN® prosthetic disc-nucleus device10.1007/s00586-002-0425-7 ↗
64. Nucleus replacement device failure: a case report and biomechanical study10.1097/BRS.0b013e3181dfbc78 ↗
65. Characterisation of porous knitted titanium for replacement of intervertebral disc nucleus pulposus10.1038/s41598-017-16863-8 ↗
66. 7.13 nucleus replacements
67. Stiffness of prosthetic nucleus determines stiffness of reconstructed lumbar calf disc10.1016/j.spinee.2003.11.003 ↗
68. Biomechanical characterization of an annulus-sparing spinal disc prosthesis10.1016/j.spinee.2009.04.026 ↗
69. Nucleus replacement of the intervertebral disc
70. Replacing the nucleus pulposus of the intervertebral disc10.1016/S0268-0033(01)00042-0 ↗
71. Preclinical evaluation of a poly (vinyl alcohol) hydrogel implant as a replacement for the nucleus pulposus10.1097/01.BRS.0000113871.67305.38 ↗
72. Intervertebral disc and nucleus replacement devices and instrumentations10.2174/1874764711306020007 ↗
73. (iv) Lumbar stabilisation techniques10.1016/j.cuor.2006.01.006 ↗
74. A memory coiling spiral as nucleus pulposus prosthesis
75. A spiral implant as nucleus prosthesis in the lumbar spine10.1007/s00586-002-0444-4 ↗
76. Biomechanics of lumbar disk arthroplasty
77. Autologous disc chondrocyte transplantation
78. Disc chondrocyte transplantation in a canine model: a treatment for degenerated or damaged in- tervertebral disc10.1097/01.BRS.0000097891.63063.78 ↗
79. Lewandrowski · 2003
80. Novel associated hydrogels for nucleus pulposus replacement10.1002/jbm.a.10119 ↗
81. The effect of dehydration history on PVA/PVP hydrogels for nucleus pulposus replacement10.1002/jbm.b.20023 ↗
82. The effect of hydrogel nucleus implant on the mechanical behavior of the lumbar functional spinal unit: an experimental study
83. A. Traynelis, N.R.O. Pe, K. Myint, E. Martz, H.A. Yuan, Mechanical and Biomechanical Characterization of a Polyurethane Nucleus Replacement Device Injected and Cured in Situ within a Balloon, (n.d.).
84. Nucleus replacement technologies
85. Nucleus replacement with the DASCOR disc arthroplasty device: interim two-year efficacy and safety results from two prospective, non-randomized multicenter European studies10.1097/BRS.0b013e3181a3967f ↗
86. M. Songer, L. Pimenta, D. Werner, A. Reyes-Sanchez, M. Balsano, U. Agrillo, D. Coric, K. Davenport, H. Yuan, Nubac Disc Arthroplasty: Preclinical Studies and Preliminary Safety and EfÄcacy Evaluations, (n.d.).
87. Nucleus prosthesis: a new concept10.1007/s00586-002-0443-5 ↗
88. An injectable nucleus replacement as an adjunct to microdiscectomy: 2 year follow-up in a pilot clinical study10.1007/s00586-009-1136-0 ↗
89. Brown · Spine · 2010 · 35 · E77410.1097/BRS.0b013e3181d59e45 ↗
90. Nucleus disc arthroplasty with the NUBACTM device: 2-year clinical experience10.1007/s00586-011-1752-3 ↗
91. Biomechanical assessment and fatigue characteristics of an articulating nucleus implant10.1016/j.ijsp.2013.10.001 ↗
92. Lumbar nucleus replacement
93. Intervertebral disc joint replacement technology
94. New technologies in spine: nucleus replacement10.1097/00007632-200206010-00020 ↗
95. Nucleus pulposus replacement and regeneration/repair technologies: present status and future prospects10.1002/jbm.b.32712 ↗
96. Finite helical axes of motion are a useful tool to describe the three-dimensional in vitro kinematics of the intact, injured and stabilised spine10.1007/s00586-004-0710-8 ↗
97. A. Kettler, H.-P. Kaps, B. Haegele, H.-J. Wilke, Biomechanical Behavior of a New Nucleus Prosthesis Made of Knitted Titanium Filaments, (n.d.).
98. Biomechanical and in vivo evaluation of experimental closure devices of the annulus fibrosus designed for a goat nucleus replacement model10.1007/s00586-010-1384-z ↗
99. Clinical results of intradiscal hydrogel administration (GelStix) in lumbar degenerative disc disease
100. Design and clinical application of injectable hydrogels for musculoskeletal therapy10.1002/btm2.10295 ↗