Nitinol versus stainless steel stents: acute thrombogenicity study in an ex vivo porcine model
Source abstract
Abstract
Acute and subacute stents thrombosis along with thrombus mediating neointimal proliferation within the stent struts remain major concerns in coronary stenting. Up to date, there is an obvious lack of data on the thrombogenicity of stent materials in physiological conditions. This study was performed to compare the relative thrombogenicity of nitinol versus stainless steel stents. Nitinol stents were laser cut to reproduce the exact geometry of the stainless steel Palmaz stents and tested in an ex vivo AV shunt porcine model under controlled conditions. Nitinol stents presented only small amounts of white and/or red thrombus principally located at the strut intersections while Palmaz stents clearly exhibited more thrombus. As a result, 125I-fibrin(ogen) adsorption and (111)I-platelets adhesion were significantly lower on nitinol than on stainless steel devices (36%, p = 0.03 for fibrin(ogen) and 63%, p = 0.01 for platelet). These results were confirmed by scanning electron observations showing different thrombus morphologies for nitinol and stainless steel. Along with the unique mechanical properties of nitinol, its promising haemocompatibility demonstrated in our study may promote their increasing use for both peripheral and coronary revascularization procedures.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Coronary Interventions and Diagnostics · Vascular Procedures and Complications · Cardiac Valve Diseases and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (33)
Show source-provided references
1. A comparison of balloon expendable-stent implantation with balloon angioplasty in patients with coronary artery disease10.1056/NEJM199408253310801 ↗
2. On behalf of the BENESTENT investigators. Outcome following elective stent implantation in small coronary arteries (abstr)
3. Antithrombotic stent coatings
4. Comparison of aggressive versus nonaggressive balloon dilatation for stent deployment on late loss and restenosis in native coronary arteries10.1016/S0002-9149(97)01017-5 ↗
5. Subacute thrombosis and vascular injury resulting from slotted-tube Nitinol and stainless steel stents in a rabbit carotid artery model10.1161/01.CIR.94.7.1733 ↗
6. Temporary arterial stenting10.1002/(SICI)1097-0304(199705)41:1<85::AID-CCD19>3.0.CO;2-P ↗
7. Progressive vascular remodeling and reduced neointimal formation after placement of a thermoelastic self-expanding Nitinol stent in an experimental model10.1002/(SICI)1097-0304(199806)44:2<193::AID-CCD13>3.0.CO;2-O ↗
8. Ryhanen J. Biocompatibility Evaluation of nickel-titanium shape memory metal alloy, Oulu University Press, 1999.
9. Effects of surface treatment and sterilisation processes on the corrosion behavior of NiTi shape memory alloy10.1002/1097-4636(20000915)51:4<685::AID-JBM17>3.0.CO;2-S ↗
10. First clinical experience with new nitinol self-expanding stents in peripheral arteries
11. Angiographic and clinical outcome of a new self-expanding intracoronary stent (RADIUS)10.1002/(SICI)1522-726X(200004)49:4<401::AID-CCD11>3.0.CO;2-4 ↗
12. Acute thrombogenicity of intact and injured natural blood conduits versus synthetic conduits10.1002/(SICI)1097-4636(19970315)34:4<477::AID-JBM8>3.0.CO;2-H ↗
13. Blood flow and antithrombotic drug effects10.1016/S0002-8703(98)70241-8 ↗
14. The role of adsorbed proteins in animal cell adhesion, Colloids and Surfaces10.1016/0927-7765(94)80037-5 ↗
15. Metallic surface modification
16. Makkar RR, Kaul S, Nakamura M, Dev V, Litvack FI, Park K, Modulation of acute stent thrombosis by metal surface characteristics and shear rate (abstr). Circulation 1995;92(8):I-86.
17. Adhesion and activation of platelets and polymorphonuclear granulocyte cells at TiO2 surfaces10.1016/S0022-2143(97)90159-1 ↗
18. Effect of modification of oxide layer on NiTi stent corrosion resistance10.1002/(SICI)1097-4636(199824)43:4<433::AID-JBM11>3.0.CO;2-# ↗
19. The electrochemical aspects of the thrombogenicity of a material
20. Biocompatibility of the silicon-carbide coated Biotronik stent (abstr)
21. Silicon carbide coating- a semi-conducting hybrid design of coronary stents—feasibility study
22. Blood compatibility of amorphous titanium oxide films synthetized by ion beam enhanced deposition10.1016/S0142-9612(98)00212-9 ↗
23. Sutton CS, Consigny PM, Thakur M. Thrombogenicity of intravascular stent wires (abstr). Circulation 1994;90(suppl I):I-9.
24. Armitage DA, Grant DM, Parker TL, Parker KG. Haemocompatibility of surface modified NiTi, In: SMST-97: Proceedings of the second international conference on shape memory and superelastic technologies, Pacific Grove, USA; 1997. p. 411–6.
25. Endovascular stent design dictates experimental restenosis and thrombosis10.1161/01.CIR.91.12.2995 ↗
26. Neointimal tissue responses at sites of coronary stenting in humans—Macroscopic, histological and immunohistochemical analyses10.1161/01.CIR.98.3.224 ↗
27. The EPILOG Investigators, Platelet glycoprotein IIb/IIIa receptor blockade and low-dose heparin during percutaneous coronary revascularization. N Engl J Med 1997;336(24):1689–96.10.1056/NEJM199706123362401 ↗
28. The EPISTENT Investigators, Randomised placebo-controlled and balloon-angioplasty-controlled trial to assess safety of coronary stenting with use of platelet glycoprotein-IIb/IIIa blockade. Lancet 1998;352(9122):87–92.10.1016/S0140-6736(98)85010-1 ↗
29. Differences in endothelial injury after balloon angioplasty, insertion of balloon-expanded stents or release of self-expanding stents10.1007/s002709900329 ↗
30. Acute and chonic effects of self-expanding nitinol stents in porcine coronary arteries10.1097/00019501-199701000-00007 ↗
31. Continued expansion of the nitinol self-expanding coronary stent10.1016/S0002-8703(99)70120-1 ↗
32. Extracorporeal Circulation10.1161/01.CIR.97.1.117 ↗
33. Sheep, pigs, and human platelets-material interactions with model cardiovascular biomaterials10.1002/(SICI)1097-4636(19990605)45:3<240::AID-JBM12>3.0.CO;2-C ↗