Immobilization of poly(ethylene glycol) or its sulfonate onto polymer surfaces by ozone oxidation
Source abstract
Abstract
A novel surface modification method has been developed to improve biocompatibility of polymeric biomaterials. This approach involves ozonation and then followed by graft polymerization with acrylates containing PEG, sulfonated PEG or by coupling of PEG derivatives. All the reactions were confirmed by ATR FT-IR and ESCA. The degree of ozonation measured by the iodide method was dependent on the ozone permeability of the polymers used. Surface hydrophilicity was investigated by measuring the contact angles. Ozonation itself yielded a slight increase in hydrophilicity and a decrease in platelet adhesion, but PEG immobilization showed a significant effect on surface hydrophilicity and platelet adhesion to confirm well-known PEG's passivity which minimize the adhesion of blood components on polymer surfaces. Both graft polymerization and coupling were effective for PU. In contrast, only grafting gave enough yields for PMMA and silicone. Platelet adhesion results demonstrated that all PEG modified surfaces adsorbed lower platelet adhesion than untreated or ozonated ones. Polymers coupled with sulfonated PEG exhibited the lowest platelet adhesion when compared with control and PEG coupled ones by virtue of the synergistic effect of non-adhesive PEG and negatively charged SO3 groups. This PEG or sulfonated PEG immobilization technology using ozonation is relatively simple for introducing uniform surface modification and therefore very useful for practical application of blood contacting medical devices.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Polymer Surface Interaction Studies · Electrospun Nanofibers in Biomedical Applications · Polymer Nanocomposite Synthesis and Irradiation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. Blood compatible polymers
2. Blood compatible polymers
3. Surface modification of polymers for medical applications10.1016/0142-9612(94)90025-6 ↗
4. A new antithrombogenic material with long PEG chains
5. Poly(ethylene oxide) as a biomaterial
6. Protein-resistant surfaces prepared by PEO-containing block copolymer surfactants10.1002/jbm.820230306 ↗
7. Biological response to PEG modified PET surfaces10.1002/jbm.820250704 ↗
8. PEO modified surface-blood compatibility of in vitro and in vivo studies
9. Negative cilia concept for thromboresistance10.1002/jbm.820250502 ↗
10. In vivo biostability and calcification-resistance of surface-modified PU–PEO–SO310.1002/jbm.820270812 ↗
11. Heparin-like anticoagulant activity of sulphonated PEO and sulphonated PEO grafted PU10.1016/0142-9612(95)98819-Z ↗
12. Negative cilia concept for thromboresistance
13. Ozone-induced graft polymerization onto polymer surface10.1002/pola.1993.080310426 ↗
14. Surface modification of polyolefins for hydrophilicity and bondability10.1002/app.1990.070410119 ↗
15. Graft copolymerization of methyl-methacrylate onto polypropylene oxidized with ozone
16. Preparation and characterization of cellulose-supported HEMA hydrogels10.1016/S0032-3861(96)01075-0 ↗
17. Radial block polymerization of vinyl chloride
18. Spectrophotometric determination of hydrogen peroxide and organic hydroperoxides at low concentration in aqueous solution10.1016/S0003-2670(00)85587-7 ↗
19. Synthetic pulp fiber ozonation10.1002/app.1993.070490216 ↗
20. Mayhan KG, Janssen RA, Bertrand WJ. USP 4589964, 20 May 1986.
21. Polymer surface modification to attain blood compatibility of hydrophobic polymer
22. Radiation-grafted hydrogels for biomaterial applications at studied by the ESCA technique10.1002/app.1978.070220306 ↗
23. Modification of isotactic PP by a cold plasma or an electron beam and grafting of the acrylic acid onto these activated polymers10.1002/app.1994.070531003 ↗
24. Graft polymerization of acrylamide onto UV-irradiated films10.1002/app.1988.070360509 ↗
25. Graft copolymerization of acrylamide onto a PE surface pretreated with a glow discharge10.1021/ma00161a005 ↗
26. Oxidation of PE surface by corona discharge and the subsequent graft polymerization10.1002/pola.1988.080261216 ↗
27. Modification of silicone surface by graft polymerization of acrylamide with corona discharge10.1002/macp.1991.021920804 ↗
28. Surface modification of PE by electrical discharge treatment and the mechanism of autoadhesion10.1016/0032-3861(78)90304-X ↗
29. Mechanical properties of corona-modified cellulose/PE composites10.1002/pen.760330606 ↗
30. Platelet adhesion and activation on PEG modified PU surfaces10.1097/00002480-199609000-00117 ↗