Effects of calcium ion incorporation on bone healing of Ti6Al4V alloy implants in rabbit tibiae
Source abstract
Abstract
The biocompatibility of calcium ion (Ca)-incorporated Ti6Al4V alloy implants, produced by hydrothermal treatment using a Ca-containing solution, was investigated. The surface characteristics were evaluated by scanning electron microscopy, thin-film X-ray diffractometry, Auger electron spectroscopy, and stylus profilometry. The viability of MC3T3-E1 cells on Ca-incorporated machined Ti6Al4V surfaces with different oxide thicknesses was compared with that on untreated machined Ti6Al4V surfaces with MTT assay. The osteoconductivity of the Ca-incorporated Ti6Al4V implants was evaluated by removal torque testing and histomorphometric analysis after 6 weeks of implantation in rabbit tibiae. Our results show that hydrothermal treatment with a Ca-containing solution produced a crystalline CaTiO(3) layer on Ti6Al4V surfaces, and calcium ions were gradually incorporated throughout the oxide layer. After immersion in Hank's balanced salt solution, a considerable apatite deposition was observed on all surfaces of the Ca-incorporated samples. Significant increases in cell viability (p<0.001), removal torque forces, and bone-to-implant contact values (p<0.05) were observed for Ca-incorporated Ti6Al4V implants compared with those for untreated Ti6Al4V implants.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Titanium Alloys Microstructure and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (39)
Show source-provided references
1. Interface shear strength of titanium implants with a sandblasted and acid-etched surface: a biomechanical study in the maxilla of miniature pigs10.1002/(SICI)1097-4636(199905)45:2<75::AID-JBM1>3.0.CO;2-P ↗
2. Histomorphometric and removal torque analysis for TiO2-blasted titanium implants. An experiment on dogs
3. Bone-implant contact and bone quality: evaluation of expected and actual bone contact and machined and osseotite implants surfaces
4. Effect of titanium surface roughness on human osteoblast proliferation and gene expression in vitro
5. Effects of implant surface microtopography on osteoblast gene expression10.1111/j.1600-0501.2005.01170.x ↗
6. Implant surface roughness affects osteoblast gene expression10.1177/154405910308200509 ↗
7. Concentration- and composition-dependent effects of metal ions on human MG-63 osteoblasts10.1002/jbm.10106 ↗
8. Effects of metal ions on osteoblast-like cell metabolism and differentiation10.1002/(SICI)1097-4636(199701)34:1<29::AID-JBM5>3.0.CO;2-P ↗
9. Ti-6Al-4V ion solution inhibition of osteogenic cell phenotype as a function of differentiation time course in vitro10.1016/0142-9612(96)00009-9 ↗
10. Prosthetic metals interfere with the functions of human osteoblast cells in vitro10.1097/00003086-199706000-00030 ↗
11. Influence of the surface structure of titanium materials on the adhesion of fibroblasts10.1016/0142-9612(96)87281-4 ↗
12. Response of MG63 osteoblast-like cells to titanium and titanium alloy is dependent on surface roughness and composition10.1016/S0142-9612(98)00144-6 ↗
13. Cytokine release by osteoblast-like cells cultured on implant discs of varying alloy compositions10.1034/j.1600-0501.2002.130608.x ↗
14. In vitro corrosion corrosion behavior and osteoblast response of thermally oxidized Ti6Al4V alloy10.1016/S0142-9612(02)00237-5 ↗
15. Thermal and chemical modification of titanium-aluminum-vanadium implant materials: effects on surface properties, glycoprotein adsorption, and MG63 cell attachment10.1016/j.biomaterials.2003.10.029 ↗
16. Osteoblast response to thermally oxidized Ti6Al4V alloy10.1002/jbm.a.30264 ↗
17. Mechanical and histologic examination of titanium alloy material treated by sandblasting and anodic oxidation
18. Human alveolar bone cell adhesion and growth on ion-implanted titanium10.1002/jbm.a.30032 ↗
19. Effects of calcium ion implantation on human bone cell interaction with titanium10.1016/j.biomaterials.2004.11.044 ↗
20. Oxidized titanium screws coated with calcium ions and their performance in rabbit bone
21. Suh J-Y, Jeung O-C, Choi B-J, Park J-W. Effects of a novel calcium titanate coating on the osseointegration of blasted endosseous implants in rabbit tibiae. Clin Oral Implants Res, doi:10.1111/j.1600-0501.2006.01323.x.10.1111/j.1600-0501.2006.01323.x ↗
22. Park J-W. Electrolyte solution for implant surface treatment, method for implant surface treatment using the same, and implant manufactured by the same. KR Patent No. 100611945, 2006.
23. Rapid colorimetric assay for cellular growth and survival: a application to proliferation and cytotoxicity assays10.1016/0022-1759(83)90303-4 ↗
24. A quantitative comparison of machined commercially pure titanium and titanium–aluminum–vanadium implants in rabbit bone
25. Apatite deposition on thermally and anodically oxidized titanium surfaces in a simulated body fluid10.1016/S0142-9612(03)00357-0 ↗
26. In vivo evaluation of plasma-sprayed wollastonite coating10.1016/j.biomaterials.2004.09.027 ↗
27. Bonding of chemically treated titanium implants to bone10.1002/(SICI)1097-4636(199711)37:2<267::AID-JBM17>3.0.CO;2-B ↗
28. X-ray photoelectron spectroscopy of calcium-ion-implanted titanium10.1016/0368-2048(93)80032-H ↗
29. Amount of hydroxyl radical on calcium-ion-implanted titanium and point of zero charge of constituent oxide of the surface-modified layer10.1023/A:1008847014938 ↗
30. Binding affinity of metal ions to the CD11b A-domain is regulated by integrin activation and ligands10.1074/jbc.M402901200 ↗
31. Mechanism of BMP-2 stimulated adhesion of osteoblastic cells to titanium alloy10.1016/S0248-4900(99)80037-9 ↗
32. Increased osteoblast adhesion on titanium-coated hydroxyapatite that forms CaTiO310.1002/jbm.a.10160 ↗
33. A study on the mechanism of protein adsorption to TiO210.1016/0142-9612(91)90057-H ↗
34. Mechanism of adsorption of human albumin to titanium in vitro10.1002/(SICI)1097-4636(19970905)36:3<387::AID-JBM13>3.0.CO;2-B ↗
35. Characterization of titanium surfaces with calcium and phosphate and osteoblast adhesion10.1016/j.biomaterials.2003.10.044 ↗
36. Diverse mechanisms of osteoblast spreading on hydroxyapatite and titanium10.1016/S0142-9612(99)00264-1 ↗
37. Specific proteins mediate enhanced osteoblast adhesion on nanophase ceramics10.1002/1097-4636(20000905)51:3<475::AID-JBM23>3.0.CO;2-9 ↗
38. Effects of calcium ion implantation on osseointegration of surface blasted titanium alloy femoral implants in a canine total hip arthroplasty model10.1016/j.arth.2003.10.001 ↗
39. The significance of the surface properties of oxidized titanium to the bone response: special emphasis on potential biochemical bonding of oxidized titanium implant10.1016/S0142-9612(03)00261-8 ↗