A conductive ormosil encapsulated with ferrocene conjugate and multiwall carbon nanotubes for biosensing application
Source abstract
Abstract
Highly non-toxic and conductive ormosil composite film was prepared using (3-aminopropyl)triethoxysilane and 2-(3,4-epoxycyclohexyl)-ethyltrimethoxysilane by doping with ferrocenemonocarboxylic acid-bovine serum albumin (FMC-BSA) conjugate and multiwall carbon nanotubes (MWNTs). With glucose oxidase (GOD) as a model enzyme this film could be used to design an amperometric biosensor for glucose determination. The entrapped FMC-BSA conjugate performed excellent redox electrochemistry and the immobilized GOD was highly stable. Under optimal conditions this biosensor was able to detect glucose with a detection limit of 20 microm (S/N=3) in the linear range of 0.05-20.0 mm in flow system, which was wider than the batch amperometric mode, with an analysis time of 25 s for each sample. The value of K(M)(app) was 6.6 mm. The proximity of these three components FMC-BSA, MWNTs and GOD enhanced the electron transfer between the film and electrode. This film could be used efficiently for the entrapment of other redox bioactive compounds and biosensing/bioelectrochemical applications.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Electrochemical sensors and biosensors · Analytical Chemistry and Sensors · Advanced biosensing and bioanalysis techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (31)
Show source-provided references
1. Enzymes and other proteins entrapped in sol–gel materials10.1021/cm00046a008 ↗
2. Immobilization of Biomolecules in sol–gels: biological and analytical applications
3. Organically modified sol–gel/chitosan composite based glucose biosensor10.1002/elan.200390076 ↗
4. Recent trends in analytical application of organically modified silicate matrices10.1016/S0165-9936(01)00125-X ↗
5. Studies on glucose biosensors based on nonmediated and mediated electrochemical oxidation of reduced glucose oxidase encapsulated within organically modified sol–gel glasses10.1002/(SICI)1521-4109(199911)11:17<1251::AID-ELAN1251>3.0.CO;2-M ↗
6. An Ormosil based peroxidebiosensor—a comparative study on direct electron transport from horseradish peroxidase10.1016/S0925-4005(00)00669-9 ↗
7. Acetylthiocholine/acetylcholine and thiocholine/choline electrochemical biosensors/sensors based on an organically modified sol-gel glass enzyme reactor and graphite paste electrode10.1016/S0925-4005(99)00367-6 ↗
8. Glucose sensor for flow injection analysis of serum glucose based on immobilization of glucose oxidase in titatina sol–gel membrane10.1016/S0956-5663(03)00199-4 ↗
9. A novel ferrocene-encapsulated palladium-linked ormosil-based electrocatalytic biosensor. The role of the reactive functional group10.1002/1521-4109(200112)13:18<1519::AID-ELAN1519>3.0.CO;2-Y ↗
10. Sol–gel derived ceramic-carbon nanotube nanocompsote electrodes: tunable electrode dimension and potential electrochemical applications10.1021/ac0492867 ↗
11. Carbon nanotube aqueous sol-gel composite: enzyme friendly platforms for the development of stable biosensors10.1016/j.ab.2004.02.025 ↗
12. Preparation of biosensors based in a siloxane homoployemer with interacting ferrocene for the amperometric detection of peroxides10.1016/j.snb.2004.02.043 ↗
13. Tethered mediator biosensor. Mediated electron transfer between redox enzyme and electrode via ferrocene anchored to electrode surface with long poly(oxyethylene) chain10.1016/S0956-5663(98)00113-4 ↗
14. Intramolecular electron-transfer rates in ferrocene-derivatized glucose oxidase10.1021/ja00069a001 ↗
15. Direct electrochemical communication between chemically modified enzymes and metal electrodes. 1. Electron transfer from glucose oxidase to metal electrodes via electron relays, bound covalently to the enzymes10.1021/j100290a001 ↗
16. Construction of electrochemical flow immunoassay system using capillary columns and ferrocene conjugated immunoglobulins G for detection of hCG10.1016/S0956-5663(01)00228-7 ↗
17. Ferrocene-avidin conjugates for bioelectrochemical applpications10.1016/S0956-5663(00)00106-8 ↗
18. Electron transfer between redox enzymes and electrodes through the artificial redox proteins and its application biosensors10.1016/S0925-4005(99)00425-6 ↗
19. Charge transport effects in ferrocene-streptavidin multilayers immobilized on electrode surfaces10.1016/S0013-4686(02)00746-6 ↗
20. A chitosan multiwall carbon nanotube modified electrode for simultaneous detection of dopamine and ascorbic acid10.2116/analsci.20.1055 ↗
21. Rotating ring disk enzyme electrode for biocatalysis kinetic studies and characterization of the immobilized enzyme layer10.1021/ac50058a010 ↗
22. Interaction of d-glucal with Aspergillus niger glucose oxidase10.1021/bi00801a005 ↗
23. Amperometric glucose biosensor based on sol–gel organic–inorganic hybrid material10.1021/ac980160h ↗
24. Amperometric glucose biosensors based on Prussian blue and polyaniline glucose oxidase modified electrodes10.1016/S0956-5663(00)00101-9 ↗
25. Electro polymerization of pyrrole and immobilization of glucose oxidase in a flow system: influence of the operating conditions on analytical performance10.1016/S0956-5663(97)00116-4 ↗
26. Glucose oxidase bound to self assembled monolayers of bis (4-pyridyl) disulfide at a gold electrode: amperometric determination of glucose10.1016/S0003-2670(98)00083-X ↗
27. Development of an enzymeless/mediatorless glucose sensor using ruthenium oxide-Prussian blue combinative analogue10.1002/elan.200403086 ↗
28. Determination of glucose in blood using glucose oxidase with an alternative oxygen acceptor10.1177/000456326900600108 ↗
29. Needle-type dual microsensor for the simultaneous moniting of glucose and insulin10.1021/ac0009393 ↗
30. Can continuous glucose monitoring be used for the treatment of diabetes
31. Enzyme thermostabilization by bovine serum albumin and other proteins: evidence for hydrophobic interactions10.1111/j.1470-8744.1995.tb00346.x ↗