The wear of orthopaedic prostheses results in the release of a markedly heterogeneous assortment of particulate debris, with respect to both size and shape. Although particle size has been extensively examined, the role of particle shape in adverse inflammatory reactions to debris remains unclear. Using an in vivo murine model of inflammation, we assessed tissue responses to globular and to elongated ultra-high molecular weight polyethylene (UHMWPE) particles with a similar surface area, and investigated whether inflammation and cellular apoptosis varied with particle shape in the debris-tissue interaction. Histological changes of UHMWPE-stimulated pouch membrane were assessed using a computerized image analysis system. Quantitative real time PCR and ELISA were performed to assess mRNA expression and protein level of the cytokines, and TUNEL assays were conducted to quantify apoptotic cells. The data revealed that elongated particles generated more active inflammatory air pouches, stimulated more severe membrane proliferation and the inflammatory cellular infiltration compared to globular particles. Increased levels of IL-1beta and TNFalpha were detected in the lavage and homogenate of pouches stimulated with elongated particles in comparison to pouches with globular particles, and the apoptotic assay indicated more severe apoptotic changes within the inflammatory membrane provoked with elongated particles. Our results suggest that cellular responses to UHMWPE wear debris are dependent on the shape of the particles.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments · Total Knee Arthroplasty Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (41)

Show source-provided references
1. Results with a cementless alumina-coated cup with dual mobility. A twelve-year follow-up study10.1007/s002640050246 ↗
2. Failed cementless total hip arthroplasty for osteoarthrosis due to hip dysplasia. A minimum five-year follow-up study
3. Cementless porous-coated anatomic medullary locking total hip prostheses10.1016/0883-5403(94)90078-7 ↗
4. The response to particulate debris10.1016/S0030-5898(20)31836-8 ↗
5. Clinical reviews10.1002/jab.770040310 ↗
6. The synovial-like membrane at the bone–cement interface in loose total hip replacements and its proposed role in bone lysis10.2106/00004623-198365050-00001 ↗
7. Biochemical and histological evaluation of the synovial-like tissue around failed (loose) total joint replacement prostheses in human subjects and a canine model
9. Endosteal erosion in association with stable uncemented femoral components10.2106/00004623-199072070-00011 ↗
10. Composition and morphology of wear debris in failed uncemented total hip replacement10.1302/0301-620X.76B1.8300684 ↗
11. In vivo and in vitro analysis of membranes from hip prostheses inserted without cement10.2106/00004623-199402000-00002 ↗
12. The synovial response to intraarticular injection in rats of polyethylene wear particles10.1097/00003086-199307000-00046 ↗
13. The pathology of total joint arthroplasty. II. Mechanisms of implant failure [Review]10.1007/s002560050552 ↗
14. Isolation and characterization of wear particles generated in patients who have had failure of a hip arthroplasty without cement10.2106/00004623-199509000-00002 ↗
15. Isolation and characterization of debris in membranes around total joint prostheses10.2106/00004623-199411000-00010 ↗
16. Quantitative analysis of ultrahigh molecular weight polyethylene (UHMWPE) wear debris associated with total knee replacements10.1002/(SICI)1097-4636(2000)53:1<100::AID-JBM14>3.0.CO;2-4 ↗
17. Isolation and characterization of polyethylene wear debris associated with osteolysis following total shoulder arthroplasty10.2106/00004623-199901000-00005 ↗
18. Flow cytometric analysis of macrophage response to ceramic and polyethylene particles10.1002/(SICI)1097-4636(19980915)41:4<600::AID-JBM12>3.0.CO;2-I ↗
19. Induction of macrophage apoptosis by ceramic and polyethylene particles in vitro10.1016/S0142-9612(98)00214-2 ↗
20. Inflammatory responses to orthopaedic biomaterials in the murine air pouch10.1016/S0142-9612(01)00134-X ↗
21. Cellular immune responses to orthopaedic implant materials following cemented total joint replacement10.1002/jor.1100150613 ↗
22. Sheehan DC, Hrapchak BB. Theory and practice of histotechnology. 2nd ed. Columbus: Battelle Press, 1980. p. 301–2.
23. A high ratio of apoptosis to proliferation correlates with improved survival after radiotherapy for cervical adenocarcinoma10.1016/S0360-3016(99)00081-4 ↗
24. The formation of a structure with the features of synovial lining by subcutaneous injection of air10.1002/path.1711340205 ↗
25. Anti-inflammatory cytokine gene therapy in a murine model of aseptic loosening
26. Prolonged inflammatory reactions induced by artificial ceramics in the rat air pouch model
27. Characterization of the inflammatory response to biomaterials using a rodent air pouch model10.1002/(SICI)1097-4636(20000605)50:3<365::AID-JBM10>3.0.CO;2-X ↗
28. In vivo inflammatory response to polymethylmethacrylate particulate debris10.1002/jor.1100120111 ↗
29. Mechanism and clinical significance of wear debris-induced osteolysis [Review]10.1097/00003086-199203000-00003 ↗
30. Polyethylene debris-induced osteolysis and loosening in uncemented total hip arthroplasty. A cause of late failure10.1016/0883-5403(92)90050-Z ↗
31. Macrophage activation and migration in interface tissue around loosening total hip arthroplasty components10.1002/(SICI)1097-4636(19970605)35:3<399::AID-JBM14>3.0.CO;2-A ↗
32. The pathology of failed total joint arthroplasty10.1097/00003086-198210000-00023 ↗
33. Tissue reactions to joint prostheses and the products of wear and corrosion
34. Wear particulate species and bone loss in failed total joint arthroplasties10.1097/00003086-199707000-00016 ↗
35. The size and shape of particulate polyethylene wear debris in total joint replacements10.1243/0954411971534638 ↗
36. Characterization of debris adjacent to failed knee implants of 3 different designs10.1097/00003086-199610000-00021 ↗
37. Biological reactions to wear debris in total joint replacement10.1243/0954411001535219 ↗
38. The origin of submicron polyethylene wear debris in total hip arthroplasty
39. Molecular and clinical aspects of apoptosis10.1016/S0163-7258(96)00098-8 ↗
40. Apoptosis and disease10.1146/annurev.med.48.1.267 ↗
41. Bisphosphonates promote apoptosis in murine osteoclasts in vitro and in vivo10.1002/jbmr.5650101008 ↗